Current status and prospects for microbubbles in ultrasound theranostics
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Encapsulated microbubbles have been developed over the past two decades to provide improvements both in imaging as well as new therapeutic applications. Microbubble contrast agents are used currently for clinical imaging where increased sensitivity to blood flow is required, such as echocardiography. These compressible spheres oscillate in an acoustic field, producing nonlinear responses which can be uniquely distinguished from surrounding tissue, resulting in substantial enhancements in imaging signal‐to‐noise ratio. Furthermore, with sufficient acoustic energy the oscillation of microbubbles can mediate localized biological effects in tissue including the enhancement of membrane permeability or increased thermal energy deposition. Structurally, microbubbles are comprised of two principal components—an encapsulating shell and an inner gas core. This configuration enables microbubbles to be loaded with drugs or genes for additional therapeutic effect. Application of sufficient ultrasound energy can release this payload, resulting in site‐specific delivery. Extensive preclinical studies illustrate that combining microbubbles and ultrasound can result in enhanced drug delivery or gene expression at spatially selective sites. Thus, microbbubles can be used for imaging, for therapy, or for both simultaneously. In this sense, microbubbles combined with acoustics may be one of the most universal theranostic tools. WIREs Nanomed Nanobiotechnol 2013, 5:329–345. doi: 10.1002/wnan.1219 This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies Diagnostic Tools > In Vivo Nanodiagnostics and Imaging
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Folkman, J. (2006) · Annual Review of Medicine · doi:10.1146/annurev.med.57.121304.131306 · Cited by 1,209
Cited by
Elbaz, M., Ad-El, N., Chulanova, Y., Brier, D., Goldsmith, M., Bismuth, M., Brosque, A., Sher, D., Gutkin, A., Bar-On, D., et al. (2025) · doi:10.1101/2025.01.23.634427 · Cited by 43
Wang, H., Ding, L., Xu, F., He, L., Ye, L., Huang, L., Zhang, L., & Luo, B. (2021) · Journal of Biomaterials Applications · doi:10.1177/08853282211011766 · Cited by 26
“Due to its noninvasiveness, non-ionizing radiation, easy operation, real-time dynamic imaging, and almost no side effects, if used properly, ultrasound imaging has been widely used in medical imaging.(2,3) Ultrasound contrast agent (UCA) can significantly enhance ultrasound signals, its application enhances its role i…”
MethodUltrasound-induced immune responses in tumors: A systematic review and meta-analysis
Rix, A., Heinrichs, H., Porte, C., Leenaars, C., Bleich, A., & Kiessling, F. (2024) · Journal of Controlled Release · doi:10.1016/j.jconrel.2024.05.030 · Cited by 21
Rouhi, N., Chakeri, Z., Ghorbani Nejad, B., Rahimzadegan, M., Rafi Khezri, M., Kamali, H., & Nosrati, R. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e37533 · Cited by 20
Metadata
- Authors
- Martin, K. H., & Dayton, P. A.
- Venue
- WIREs Nanomedicine and Nanobiotechnology
- Publisher
- Wiley
- Published
- 2013-03-15
- Volume
- 5
- Issue
- 4
- Pages
- 329-345
- ISSN
- 1939-0041 (ISSN-L)
- 1939-5116
- OpenAlex
- W2138215047
- Cited by
- 148
- References
- 1
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.