The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
In vivo near‐infrared fluorescence imaging of cancer with nanoparticle‐based probes
Abstract
The use of in vivo near‐infrared fluorescence (NIRF) imaging techniques for sensitive cancer early detection is highly desirable, because biological tissues show very low absorption and autofluorescence in the NIR spectrum window. Cancer NIRF molecular imaging relies greatly on stable, highly specific and sensitive molecular probes. Nanoparticle‐based NIRF probes have overcome some of the limitations of the conventional NIRF organic dyes, such as poor hydrophilicity and photostability, low quantum yield, insufficient stability in biological system, low detection sensitivity, etc. Therefore, a lot of efforts have been made to actively develop novel NIRF nanoparticles for in vivo cancer molecular imaging. The main focus of this article is to provide a brief overview of the synthesis, surface modification, and in vivo cancer imaging applications of nanoparticle‐based NIRF probes, including dye‐containing nanoparticles, NIRF quantum dots, and upconversion nanoparticles. WIREs Nanomed Nanobiotechnol 2010 2 349–366 This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > In Vivo Nanodiagnostics and Imaging
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabbousi, B. O., Rodriguez-Viejo, J., Mikulec, F. V., Heine, J. R., Mattoussi, H., Ober, R., Jensen, K. F., & Bawendi, M. G. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp971091y · Cited by 4,229
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Perspectives on the Physical Chemistry of Semiconductor Nanocrystals
Alivisatos, A. P. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp9535506 · Cited by 3,595
Nanocrystal Core High-Density Lipoproteins: A Multimodality Contrast Agent Platform
Cormode, D. P., Skajaa, T., van Schooneveld, M. M., Koole, R., Jarzyna, P., Lobatto, M. E., Calcagno, C., Barazza, A., Gordon, R. E., Zanzonico, P., et al. (2008) · Nano Letters · doi:10.1021/nl801958b · Cited by 328
Cited by
Nanoparticle PEGylation for Imaging and Therapy
Jokerst, J. V., Lobovkina, T., Zare, R. N., & Gambhir, S. S. (2011) · Nanomedicine · doi:10.2217/nnm.11.19 · Cited by 2,046
A review of NIR dyes in cancer targeting and imaging
Luo, S., Zhang, E., Su, Y., Cheng, T., & Shi, C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.024 · Cited by 1,432
Bose, S., & Tarafder, S. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.017 · Cited by 958
Noble Metal Nanoparticles for Biosensing Applications
Doria, G., Conde, J., Veigas, B., Giestas, L., Almeida, C., Assunção, M., Rosa, J., & Baptista, P. V. (2012) · Sensors · doi:10.3390/s120201657 · Cited by 708
Carbon nanotube based biosensors
Yang, N., Chen, X., Ren, T., Zhang, P., & Yang, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.10.040 · Cited by 542
Metadata
- Authors
- He, X., Wang, K., & Cheng, Z.
- Venue
- WIREs Nanomedicine and Nanobiotechnology
- Publisher
- Wiley
- Published
- 2010-06-17
- Volume
- 2
- Issue
- 4
- Pages
- 349-366
- ISSN
- 1939-0041 (ISSN-L)
- 1939-5116
- OpenAlex
- W2035032184
- Cited by
- 232
- References
- 4
- FWCI
- 14.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo near‐infrared fluorescence imaging of cancer with nanoparticle‐based probes. https://app.cochat.ai/papers/10.1002/wnan.85
- The paper
- He, X., Wang, K., & Cheng, Z. (2010). In vivo near‐infrared fluorescence imaging of cancer with nanoparticle‐based probes. WIREs Nanomedicine and Nanobiotechnology. https://doi.org/10.1002/wnan.85
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.