CoChat

The Arterial Windkessel

Westerhof, Nicolaas, Stergiopulos, Nikolaos, Noble, Mark I. M. · 2010 · Snapshots of Hemodynamics

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Overview

Integrity signals

Registry

Crossref · 10.1007/978-1-4419-6363-5_24

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 4

  1. Westerhof N, Elzinga G, Sipkema P. An artificial system for pumping hearts. J Appl Physiol1971;31:776–781.
  2. Stergiopulos N, Meister J-J, Westerhof N. Evaluation of methods for estimating total arterial compliance. Am J Physiol 1995;268:H1540–H1548.
  3. Segers P, Brimioulle S, Stergiopulos N, Westerhof N, Naeije R, Maggiorini M, Verdonck P. Pulmonary arterial compliance in dogs and pigs: the three-element windkessel model ­revisited. Am J Physiol 1999;277:H725–H731.
  4. Toorop GP, Westerhof N, Elzinga G. Beat-to beat estimation of peripheral resistance and ­arterial compliance during pressure transients. Am J Physiol 1987;252:H1275–H1283.

Cited by

See all 5

Metadata

Authors
Westerhof, N., Stergiopulos, N., & Noble, M. I. M.
Affiliations
  • Amsterdam Cardiovascular Sciences (NL)
  • École Polytechnique Fédérale de Lausanne (CH)
  • University of Aberdeen (GB)
Corresponding author
Westerhof, Nicolaas
Venue
Snapshots of Hemodynamics
Publisher
Springer US
Published
2010
Pages
173-181
OpenAlex
W4244137128
Cited by
5
References
10
Citations by year
2026: 1 · 2022: 2 · 2019: 1
FWCI
0.00
Type
book chapter
Language
en
Open access
closed
Locations
Springer eBooks (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
Windkessel model, arterial compliance, systemic vascular resistance, time constant, cardiac output estimation, aortic pressure, pulse wave velocity, aortic compliance, pulsatile flow

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.