Experimental Aspects of Polarization Optimized Experiments (POE) for Magic Angle Spinning Solid-State NMR of Microcrystalline and Membrane-Bound Proteins
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index; none of the 2 sources its claims cite is checked for support yet.
Abstract
Conventional NMR pulse sequences record one spectrum per experiment, while spending most of the time waiting for the spin system to return to the equilibrium. As a result, a full set of multidimensional NMR experiments for biological macromolecules may take up to several months to complete. Here, we present a practical guide for setting up a new class of MAS solid-state NMR experiments (POE or polarization optimized experiments) that enable the simultaneous acquisition of multiple spectra of proteins, accelerating data acquisition. POE exploit the long-lived 15 N polarization of isotopically labeled proteins and enable one to obtain up to eight spectra, by concatenating classical NMR pulse sequences. This new strategy propels data throughput of solid-state NMR spectroscopy of fibers, microcrystalline preparations, as well as membrane proteins.
Overview
CoChat Summary
TL;DR
This chapter presents polarization optimized experiments (POE) for MAS solid-state NMR, which concatenate classical pulse sequences to acquire multiple 2D spectra simultaneously from long-lived 15N polarization. Using DUMAS, MEIOSIS, MAeSTOSO-4, and MAeSTOSO-8, the authors report up to eight spectra per pulse sequence and approximately 50% reduction in experimental time for their protein samples.
Key findings
- POE enable simultaneous acquisition of multiple 2D ssNMR spectra by exploiting long-lived 15N polarization and simultaneous cross-polarization (SIM-CP); MAeSTOSO-8 can acquire up to eight different experiments simultaneously with four acquisition periods.
- Specific concatenations: DUMAS acquires CXCX and NCA; MAeSTOSO-4 acquires CXCX, NCACB, NCACX, and NCO; MEIOSIS concatenates C(N)C with CC and NC correlation experiments using two acquisitions per scan.
- For the authors’ proteins, POE-based strategies reduced experimental time by approximately 50% compared with acquiring the corresponding experiments individually in serial fashion.
- The authors state POE are most effective for membrane protein samples under moderate spinning speed conditions and with 3.2 mm or 4 mm MAS probes.
Methods
- Design: practical guide for setting up POE pulse sequences; SIM-CP creates 13C and 15N polarization pathways; multiple FIDs are deconvoluted and processed with NMRPipe scripts; spectra are externally referenced to the CH2 resonance of adamantane at 40.48 ppm.
- Samples: U-13C,15N labeled microcrystalline ubiquitin (~8 mg); U-13C,15N labeled phospholamban (PLN) and sarcolipin (SLN) reconstituted in DMPC lipids at ~1:100 protein-to-lipid ratio, typically 2–3 mg protein and 15 mg DMPC, ~30% (w/v) hydration, packed into 3.2 mm rotors.
- NMR parameters: 600 MHz Agilent spectrometers with 3.2 mm scroll coil MAS probe; recycle delay 2 s; MAS 12 kHz; 1H RF 100 kHz (2.5 μs 90°), 13C/15N RF 41.6 kHz (6 μs 90°); SIM-CP 13C/15N 35 kHz, 1H ramp center 59 kHz, contact times 300–1000 μs (typically 500 μs); TPPM 100 kHz; t2acq 20 ms for DUMAS/MEIOSIS and 15 ms for MAeSTOSO; t1 13C 256 increments (30 μs dwell), t1 15N 32 increments (300 μs dwell) with 8 loops; DARR 20–500 ms; DREAM 2.53 ms; NC mixing 3 ms.
Limitations
- Stated: POE are not an alternative to existing fast-acquisition/sensitivity methods but a concatenation strategy; optimal SIM-CP contact times vary significantly among samples depending on hydration levels; NC transfer requires careful optimization because the rotating-frame matching condition is narrow and optimal RF values deviate from theoretical values.
- Stated: For hydrated membrane protein samples, temperature affects lipid phase and sensitivity; at 25°C DMPC liquid crystalline phase promotes rotational diffusion, scaling dipolar couplings and lowering CP performance, while 0–4°C gel phase spectra are more sensitive; lower sensitivity near the liquid crystalline phase may extend acquisition time. Longer DARR mixing times reduce overall sensitivity and require more scans; MAeSTOSO t2acq is set to 15 ms to avoid RF heating.
- Evident from text: demonstrations are limited to specific samples (ubiquitin, PLN, SLN), a 600 MHz spectrometer, and a 3.2 mm scroll-coil probe; the ~50% time reduction is reported for the authors’ proteins rather than a general benchmark. Membrane protein preparations require at least 100 lipids per protein to maintain native-like conditions and avoid aggregation, which may limit applicability.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 2 Not valid · 1 Not checked · 39 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“( b ) Application of MAeSTOSO-4 (Fig. 2b) for Simultaneous acquisition of CXCX, NCACB, NCACX, and NCO spectra of ubiquitin microcrystalline protein”
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Our most recent implementation, MAeSTOSO-8, makes it possible to acquire up to eight different experiments simultaneously.”
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Utilizing POE-based strategies, for our proteins, we observed a reduction of approximately 50% of the experimental time compared to acquiring the corresponding experiments individually in a serial fashion.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Using similar strategies, the simultaneous acquisition of up to eight FIDs (MAeSTOSO-8) can be achieved with four acquisition periods (Fig. 2d).”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“On the other hand, protein spectra recorded at 0-4 C with the lipids in gel phase are more sensitive.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
11 more claims
Create a free account to see all 42 claims and to verify the 2 references still open.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 14
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Our contribution has been in the development of novel pulse sequences with higher sensitivity for both MAS and OS-ssNMR.4,46”
From Solid-State NMR of Membrane Proteins in Lipid Bilayers: To Spin or Not To Spin? (2021) · cites this paper as [4]
In the citing paper
“Along with auxiliary developments made by other research groups, the POE family now includes 1H-detected experiments under fast MAS conditions, afterglow, dipolar-edited versions of DUMAS pulse sequences, and, more recently, hybrid pulse sequences combining CP and INEPT transfer periods27–34.”
From Multi-receiver solid-state NMR using polarization optimized experiments (POE) at ultrafast magic angle spinning (2020) · cites this paper as [30]
In the citing paper
“The introduction of POE with the DUMAS, MEIOSIS, and MAeSTOSO strategies made it possible to recover orphan spin operators and utilize the full potential of nuclear spin polarization generated by CP29–34, 38, 46–47.”
From Proton-detected polarization optimized experiments (POE) using ultrafast magic angle spinning solid-state NMR: Multi-acquisition of membrane protein spectra (2020) · cites this paper as [34]
In the citing paper
“Unlike liquid samples, the longitudinal relaxation (T1) times of solids or solid-like biomacromolecules are significantly longer for 15N and 13C nuclei. Therefore, it is possible to store 15N and/or 13C polarization along the longitudinal axis (Nz or Cz) and subsequently utilize it for multiple acquisitions29, 34.”
From Proton-detected polarization optimized experiments (POE) using ultrafast magic angle spinning solid-state NMR: Multi-acquisition of membrane protein spectra (2020) · cites this paper as [34]
In the citing paper
“Here, we expanded the POE toolkit 18 by hybridizing transferred echo double resonance (TEDOR) 19–22 and spectrally induced filtering in combination with cross-polarization (SPECIFIC-CP) 23 transfer elements to record 13C-15N correlation experiments in the first and subsequence multiple acquisitions.”
From Hybridization of TEDOR and NCX MAS solid-state NMR experiments for simultaneous acquisition of heteronuclear correlation spectra and distance measurements (2019) · cites this paper as [23]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
NMRPipe: A multidimensional spectral processing system based on UNIX pipes
Delaglio, F., Grzesiek, S., Vuister, G., Zhu, G., Pfeifer, J., & Bax, A. (1995) · Journal of Biomolecular NMR · doi:10.1007/bf00197809 · Cited by 15,965
Proton-enhanced NMR of dilute spins in solids
Pines, A., Gibby, M. G., & Waugh, J. S. (1973) · The Journal of Chemical Physics · doi:10.1063/1.1680061 · Cited by 2,493
Nuclear Double Resonance in the Rotating Frame
Hartmann, S. R., & Hahn, E. L. (1962) · Physical Review · doi:10.1103/physrev.128.2042 · Cited by 2,236
Heteronuclear decoupling in rotating solids
Bennett, A. E., Rienstra, C. M., Auger, M., Lakshmi, K. V., & Griffin, R. G. (1995) · The Journal of Chemical Physics · doi:10.1063/1.470372 · Cited by 2,124
– dipolar-assisted rotational resonance in magic-angle spinning NMR
Takegoshi, K., Nakamura, S., & Terao, T. (2001) · Chemical Physics Letters · doi:10.1016/s0009-2614(01)00791-6 · Cited by 1,012
Dynamic nuclear polarization at high magnetic fields
Maly, T., Debelouchina, G. T., Bajaj, V. S., Hu, K.-N., Joo, C.-G., Mak–Jurkauskas, M. L., Sirigiri, J. R., van der Wel, P. C. A., Herzfeld, J., Temkin, R. J., et al. (2008) · The Journal of Chemical Physics · doi:10.1063/1.2833582 · Cited by 919
Structure of a protein determined by solid-state magic-angle-spinning NMR spectroscopy
Castellani, F., van Rossum, B., Diehl, A., Schubert, M., Rehbein, K., & Oschkinat, H. (2002) · Nature · doi:10.1038/nature01070 · Cited by 910
Ultrahigh Resolution in Proton Solid‐State NMR Spectroscopy at High Levels of Deuteration
Chevelkov, V., Rehbein, K., Diehl, A., & Reif, B. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200600328 · Cited by 349
Structure and Dynamics of Membrane Proteins by Magic Angle Spinning Solid-State NMR
McDermott, A. (2009) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.050708.133719 · Cited by 342
Mechanisms of Proton Conduction and Gating in Influenza M2 Proton Channels from Solid-State NMR
Hu, F., Luo, W., & Hong, M. (2010) · Science · doi:10.1126/science.1191714 · Cited by 325
Influences of Membrane Mimetic Environments on Membrane Protein Structures
Zhou, H.-X., & Cross, T. A. (2013) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-083012-130326 · Cited by 267
Adiabatic Dipolar Recoupling in Solid-State NMR: The DREAM Scheme
Verel, R., Ernst, M., & Meier, B. H. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2310 · Cited by 221
Gor’kov, P. L., Chekmenev, E. Y., Li, C., Cotten, M., Buffy, J. J., Traaseth, N. J., Veglia, G., & Brey, W. W. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.11.008 · Cited by 213
Self-citationNanomole-scale protein solid-state NMR by breaking intrinsic 1H T1 boundaries
Wickramasinghe, N. P., Parthasarathy, S., Jones, C. R., Bhardwaj, C., Long, F., Kotecha, M., Mehboob, S., Fung, L. W.-M., Past, J., Samoson, A., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1300 · Cited by 203
Membrane Protein Structure and Dynamics from NMR Spectroscopy
Hong, M., Zhang, Y., & Hu, F. (2012) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-032511-143731 · Cited by 200
Sensitive High Resolution Inverse Detection NMR Spectroscopy of Proteins in the Solid State
Paulson, E. K., Morcombe, C. R., Gaponenko, V., Dancheck, B., Byrd, R. A., & Zilm, K. W. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037315+ · Cited by 177
High-resolution proton-detected NMR of proteins at very fast MAS
Andreas, L. B., Marchand, T. L., Jaudzems, K., & Pintacuda, G. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.01.003 · Cited by 159
Stringer, J. A., Bronnimann, C. E., Mullen, C. G., Zhou, D. H., Stellfox, S. A., Li, Y., Williams, E. H., & Rienstra, C. M. (2005) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2004.11.015 · Cited by 151
Allosteric regulation of SERCA by phosphorylation-mediated conformational shift of phospholamban
Gustavsson, M., Verardi, R., Mullen, D. G., Mote, K. R., Traaseth, N. J., Gopinath, T., & Veglia, G. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1303006110 · Cited by 150
Self-citationThe chaperone αB-crystallin uses different interfaces to capture an amorphous and an amyloid client
Mainz, A., Peschek, J., Stavropoulou, M., Back, K. C., Bardiaux, B., Asami, S., Prade, E., Peters, C., Weinkauf, S., Buchner, J., et al. (2015) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.3108 · Cited by 149
Ultra-wide bore 900MHz high-resolution NMR at the National High Magnetic Field Laboratory
Fu, R., Brey, W. W., Shetty, K., Gor’kov, P. L., Saha, S., Long, J. R., Grant, S. C., Chekmenev, E. Y., Hu, J., Gan, Z., et al. (2005) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2005.07.013 · Cited by 136
Structural Rearrangements of Membrane Proteins Probed by Water-Edited Solid-State NMR Spectroscopy
Ader, C., Schneider, R., Seidel, K., Etzkorn, M., Becker, S., & Baldus, M. (2009) · Journal of the American Chemical Society · doi:10.1021/ja806306e · Cited by 124
β-Barrel Mobility Underlies Closure of the Voltage-Dependent Anion Channel
Zachariae, U., Schneider, R. C., Briones, R., Gattin, Z., Demers, J., Giller, K., Maier, E., Zweckstetter, M., Griesinger, C., Becker, S., et al. (2012) · Structure · doi:10.1016/j.str.2012.06.015 · Cited by 121
Franks, W. T., Kloepper, K. D., Wylie, B. J., & Rienstra, C. M. (2007) · Journal of Biomolecular NMR · doi:10.1007/s10858-007-9179-1 · Cited by 110
Buck, B., Zamoon, J., Kirby, T. L., DeSilva, T. M., Karim, C., Thomas, D., & Veglia, G. (2003) · Protein Expression and Purification · doi:10.1016/s1046-5928(03)00127-x · Cited by 98
Self-citationDetken, A., Hardy, E. H., Ernst, M., Kainosho, M., Kawakami, T., Aimoto, S., & Meier, B. H. (2001) · Journal of Biomolecular NMR · doi:10.1023/a:1011212100630 · Cited by 95
A low-E magic angle spinning probe for biological solid state NMR at 750MHz
McNeill, S. A., Gor’kov, P. L., Shetty, K., Brey, W. W., & Long, J. R. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.12.008 · Cited by 86
Gopinath, T., & Veglia, G. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201108132 · Cited by 84
Self-citationRecent advances in magic angle spinning solid state NMR of membrane proteins
Wang, S., & Ladizhansky, V. (2014) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2014.07.001 · Cited by 84
Detecting the “Afterglow” of13C NMR in Proteins Using Multiple Receivers
Kupče, E., Kay, L. E., & Freeman, R. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1080025 · Cited by 48
Gopinath, T., & Veglia, G. (2013) · The Journal of Chemical Physics · doi:10.1063/1.4803126 · Cited by 39
Self-citationMote, K. R., Gopinath, T., & Veglia, G. (2013) · Journal of Biomolecular NMR · doi:10.1007/s10858-013-9766-2 · Cited by 37
Self-citationBanigan, J. R., & Traaseth, N. J. (2012) · The Journal of Physical Chemistry B · doi:10.1021/jp303269m · Cited by 37
Bellstedt, P., Herbst, C., Häfner, S., Leppert, J., Görlach, M., & Ramachandran, R. (2012) · Journal of Biomolecular NMR · doi:10.1007/s10858-012-9680-z · Cited by 28
Gopinath, T., & Veglia, G. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.03.001 · Cited by 25
Self-citationGopinath, T., & Veglia, G. (2016) · Annual Reports on NMR Spectroscopy · doi:10.1016/bs.arnmr.2016.04.003 · Cited by 14
Self-citationChevelkov, V., Xiang, S., Giller, K., Becker, S., Lange, A., & Reif, B. (2015) · Journal of Biomolecular NMR · doi:10.1007/s10858-015-9902-2 · Cited by 11
Vostrikov, V. V., Gustavsson, M., Gopinath, T., Mullen, D., Dicke, A. A., Truong, V., & Veglia, G. (2016) · ACS Chemical Biology · doi:10.1021/acschembio.5b00953 · Cited by 8
Self-citation
Cited by
Solid-State NMR: Methods for Biological Solids
Ahlawat, S., Mote, K. R., Lakomek, N., & Agarwal, V. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00852 · Cited by 119
Multiplexing experiments in NMR and multi-nuclear MRI
Kupče, E., Mote, K. R., WEBB, A. G., Madhu, P. K., & Claridge, T. D. W. (2021) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2021.03.001 · Cited by 40
Solid-State NMR of Membrane Proteins in Lipid Bilayers: To Spin or Not To Spin?
Gopinath, T., Weber, D., Wang, S., Larsen, E., & Veglia, G. (2021) · Accounts of Chemical Research · doi:10.1021/acs.accounts.0c00670 · Cited by 32
Self-citationGopinath, T., & Veglia, G. (2018) · Methods · doi:10.1016/j.ymeth.2018.07.003 · Cited by 24
Self-citationGallo, A., Franks, W. T., & Lewandowski, J. R. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.07.006 · Cited by 20
Metadata
- Authors
- Gopinath, T., & Veglia, G.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- Veglia, Gianluigi
- Venue
- Methods in Molecular Biology
- Publisher
- Springer New York
- Published
- 2017-11-19
- Volume
- 1688
- Pages
- 37-53
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W2769054128
- Semantic Scholar
- 01b67e8ebb07bf50684bdee21939896bfeb73ea6
- Cited by
- 11
- References
- 38
- Citations by year
- 2023: 1 · 2022: 2 · 2021: 3 · 2020: 1 · 2019: 3 · 2018: 1
- FWCI
- 2.41
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Methods in molecular biology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
- Keywords
- magic angle spinning, solid-state NMR, microcrystalline proteins, membrane proteins, multidimensional NMR, protein fibers
- MeSH terms
- Membrane Proteins, Magnetic Resonance Spectroscopy, Protein Conformation, Guidelines as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-22, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-22 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.