Rapid Prototyping of Microstructures by Soft Lithography for Biotechnology
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This chapter describes the methods and specific procedures used to fabricate microstructures by soft lithography. These techniques are useful for the prototyping of devices useful for applications in biotechnology. Fabrication by soft lithography does not require specialized or expensive equipment; the materials and facilities necessary are found commonly in biological and chemical laboratories in both academia and industry. The combination of the fact that the materials are low-cost and that the time from design to prototype device can be short (< 24 h) makes it possible to use and to screen rapidly devices that also can be disposable. Here we describe the procedures for fabricating microstructures with lateral dimensions as small as 1 mum. These types of microstructures are useful for microfluidic devices, cell-based assays, and bioengineered surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Self-citationHigh-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Engineering cellular microenvironments to improve cell-based drug testing
Bhadriraju, K., & Chen, C. S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02273-0 · Cited by 355
Cited by
Molecularly Imprinted Polymers
BelBruno, J. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00171 · Cited by 1,654
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
Prebiotic Systems Chemistry: New Perspectives for the Origins of Life
Ruiz-Mirazo, K., Briones, C., & de la Escosura, A. (2014) · Chemical Reviews · doi:10.1021/cr2004844 · Cited by 930
Organ/body-on-a-chip based on microfluidic technology for drug discovery
Kimura, H., Sakai, Y., & Fujii, T. (2018) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2017.11.003 · Cited by 435
Fabrication of Silk Microneedles for Controlled‐Release Drug Delivery
Tsioris, K., Raja, W. K., Pritchard, E. M., Panilaitis, B., Kaplan, D. L., & Omenetto, F. G. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201102012 · Cited by 301
Metadata
- Authors
- Wolfe, D. B., Qin, D., & Whitesides, G. M.
- Venue
- Methods in Molecular Biology
- Publisher
- Humana Press
- Published
- 2009-08-14
- Volume
- 583
- Pages
- 81-107
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W23944289
- Cited by
- 62
- References
- 3
- FWCI
- 10.45
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Prototyping of Microstructures by Soft Lithography for Biotechnology. https://app.cochat.ai/papers/10.1007/978-1-60327-106-6_3
- The paper
- Wolfe, D. B., Qin, D., & Whitesides, G. M. (2010). Rapid Prototyping of Microstructures by Soft Lithography for Biotechnology. Methods in Molecular Biology. https://doi.org/10.1007/978-1-60327-106-6_3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.