Sample Preparation for STED Microscopy
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Since the discovery of the diffraction barrier in the late nineteenth century, it has been commonly accepted that with far-field optical microscopy it is not possible to resolve structural details considerably finer than half the wavelength of light. The emergence of STED microscopy showed that, at least for fluorescence imaging, these limits can be overcome. Since STED microscopy is a far-field technique, in principle, the same sample preparation as for conventional confocal microscopy may be utilized. The increased resolution, however, requires additional precautions to ensure the structural preservation of the specimen. We present robust protocols to generate test samples for STED microscopy. These protocols for bead samples and immunolabeled mammalian cells may be used as starting points to adapt existing labeling strategies for the requirements of sub-diffraction resolution microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Self-citationBruchpilot Promotes Active Zone Assembly, Ca 2+ Channel Clustering, and Vesicle Release
Kittel, R. J., Wichmann, C., Rasse, T. M., Fouquet, W., Schmidt, M., Schmid, A., Wagh, D. A., Pawlu, C., Kellner, R. R., Willig, K. I., et al. (2006) · Science · doi:10.1126/science.1126308 · Cited by 772
Live-cell imaging of dendritic spines by STED microscopy
Nägerl, U. V., Willig, K. I., Hein, B., Hell, S. W., & Bonhoeffer, T. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810028105 · Cited by 412
Cited by
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Self-citationCoaligned Dual-Channel STED Nanoscopy and Molecular Diffusion Analysis at 20 nm Resolution
Göttfert, F., Wurm, C. A., Mueller, V., Berning, S., Cordes, V. C., Honigmann, A., & Hell, S. W. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.05.029 · Cited by 298
Self-citationGroße, L., Wurm, C. A., Brüser, C., Neumann, D., Jans, D. C., & Jakobs, S. (2016) · The EMBO Journal · doi:10.15252/embj.201592789 · Cited by 281
“Samples were essentially prepared as described previously (Wurm et al , 2010).”
Self-citationWurm, C. A., Neumann, D., Lauterbach, M. A., Harke, B., Egner, A., Hell, S. W., & Jakobs, S. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1107553108 · Cited by 173
Self-citationMultiparametric Analysis of Focal Adhesions in Bidimensional Substrates
Talayero, V. C., & Vicente-Manzanares, M. (2021) · Methods in Molecular Biology · doi:10.1007/978-1-0716-0962-0_3 · Cited by 7
Metadata
- Authors
- Wurm, C. A., Neumann, D., Schmidt, R., Egner, A., & Jakobs, S.
- Venue
- Methods in Molecular Biology
- Publisher
- Humana Press
- Published
- 2009-10-24
- Volume
- 591
- Pages
- 185-199
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W99764742
- Cited by
- 81
- References
- 4
- FWCI
- 5.34
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sample Preparation for STED Microscopy. https://app.cochat.ai/papers/10.1007/978-1-60761-404-3_11
- The paper
- Wurm, C. A., Neumann, D., Schmidt, R., Egner, A., & Jakobs, S. (2010). Sample Preparation for STED Microscopy. Methods in Molecular Biology. https://doi.org/10.1007/978-1-60761-404-3_11
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.