Automatic Lacunae Localization in Placental Ultrasound Images via Layer Aggregation
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Accurate localization of structural abnormalities is a precursor for image-based prenatal assessment of adverse conditions. For clinical screening and diagnosis of abnormally invasive placenta (AIP), a life-threatening obstetric condition, qualitative and quantitative analysis of ultrasonic patterns correlated to placental lesions such as placental lacunae (PL) is challenging and time-consuming to perform even for experienced sonographers. There is a need for automated placental lesion localization that does not rely on expensive human annotations such as detailed manual segmentation of anatomical structures. In this paper, we investigate PL localization in 2D placental ultrasound images. First, we demonstrate the effectiveness of generating confidence maps from weak dot annotations in localizing PL as an alternative to expensive manual segmentation. Then we propose a layer aggregation structure based on iterative deep aggregation (IDA) for PL localization. Models with this structure were evaluated with 10-fold cross-validations on an AIP database (containing 3,440 images with 9,618 labelled PL from 23 AIP and 11 non-AIP participants). Experimental results demonstrate that the model with the proposed structure yielded the highest mean average precision (mAP=35.7%), surpassing all other baseline models (32.6%, 32.2%, 29.7%). We argue that features from shallower stages can contribute to PL localization more effectively using the proposed structure. To our knowledge, this is the first successful application of machine learning to placental lesion analysis and has the potential to be adapted for other clinical scenarios in breast, liver, and prostate cancer imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Feature Pyramid Networks for Object Detection
Lin, T.-Y., Dollar, P., Girshick, R., He, K., Hariharan, B., & Belongie, S. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.106 · Cited by 30,939
Jauniaux, E., Collins, S., & Burton, G. J. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.05.067 · Cited by 775
Self-citationFitzpatrick, K., Sellers, S., Spark, P., Kurinczuk, J., Brocklehurst, P., & Knight, M. (2014) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.12405 · Cited by 357 · cited 1×
“However, recent population studies have shown that the rate of successful prenatal diagnosis of AIP remains unsatisfactory: merely between half and two-thirds [2, 3].”
BackgroundProposal for standardized ultrasound descriptors of abnormally invasive placenta ( AIP )
Collins, S. L., Ashcroft, A., Braun, T., Calda, P., Langhoff‐Roos, J., Morel, O., Stefanovic, V., Tutschek, B., Chantraine, F., & on behalf of the European Working Group on Abnormally Invasive Placenta (EW‐AIP) (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14952 · Cited by 331 · cited 1×
“1, numerous, large, and irregular PL are more likely to occur in AIP cases than in non-AIP cases [4].”
BackgroundSelf-citationCollins, S. L., Stevenson, G. N., Noble, J. A., Impey, L., & Welsh, A. W. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10122 · Cited by 52
Self-citation
Cited by
Use of artificial intelligence and deep learning in fetal ultrasound imaging
Ramirez Zegarra, R., & Ghi, T. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26130 · Cited by 102
Artificial intelligence in obstetric ultrasound: A scoping review.
Horgan, R., Nehme, L., & Abuhamad, A. (2023) · Prenatal Diagnosis · doi:10.1002/pd.6411 · Cited by 72
“One study each focused on categorization of the placenta as normal, low‐lying or placenta previa,(27) automatic detection of placental location from ultrasound sweeps obtained from non‐specialist sonographers,(28) automated staging of placental maturity(29) and automated detection of placental lacunae.(30) The final s…”
MethodAccuracy of automated three-dimensional ultrasound imaging technique for fetal head biometry
Pluym, I. D., Afshar, Y., Holliman, K., Kwan, L., Bolagani, A., Mok, T., Silver, B., Ramirez, E., Han, C. S., & Platt, L. D. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22171 · Cited by 46
“0) Prior Cesarean delivery None 128 (90) One 10 (7) Two 4 (3) Three 1 (1) Prior laparoscopic abdominal surgery None 126 (88) One 14 (10) Two 3 (2) Prior open abdominal surgery None 138 (97) One 5 (3) Placental location Anterior 78 (55) Posterior 61 (43) Fundal 4 (3) Sonographer characteristics Assessments performed So…”
BackgroundJost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44
Metadata
- Authors
- Qi, H., Collins, S., & Noble, J. A.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer International Publishing
- Published
- 2018
- Volume
- 11071
- Pages
- 921-929
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W2890529609
- Cited by
- 16
- References
- 6
- FWCI
- 0.69
- Type
- conference paper
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Lacunae Localization in Placental Ultrasound Images via Layer Aggregation. https://app.cochat.ai/papers/10.1007/978-3-030-00934-2_102
- The paper
- Qi, H., Collins, S., & Noble, J. A. (2018). Automatic Lacunae Localization in Placental Ultrasound Images via Layer Aggregation. Lecture Notes in Computer Science. https://doi.org/10.1007/978-3-030-00934-2_102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.