Cited by 23Medical Image Segmentation TechniquesMedical Imaging and AnalysisAnatomy and Medical Technology

Patch-Based Image Similarity for Intraoperative 2D/3D Pelvis Registration During Periacetabular Osteotomy

Open access
Grupp, Robert B., Armand, Mehran, Taylor, Russell H.·2018·Lecture Notes in Computer Science

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/978-3-030-01201-4_17

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Conventional intensity-based 2D/3D registration approaches suffer from a limited capture range due to local minima in hand-crafted image similarity functions.

    “Conventional intensity-based 2D/3D registration approaches suffer from a limited capture range due to the presence of local minima in hand-crafted image similarity functions.”

    From A Fully Differentiable Framework for 2D/3D Registration and the Projective Spatial Transformers (2024) · cites this paper as [8]

    The abstract (p. 1) says existing similarity metrics struggle with the mismatch between an intact preoperative pelvis and a fractured intraoperative pelvis. Section 2.1 (pp. 3–4) describes intensity-based registration and a limitation of normalized cross-correlation, but neither passage addresses limited capture range caused by local minima. Searches for “capture range” and “local minima” found no passage supporting that explanation. (LLM, conf=0.72)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 5

  1. [8]8. Markelj, P., Tomaˇ zeviˇ c, D., Likar, B., Pernuˇ s, F.: A review of 3d/2d registration methods for image-guided interventions. Med Image Anal 16 (3) (2012) 642-661
  2. [9]9. Gong, R.H., Stewart, J., Abolmaesumi, P.: Multiple-object 2-d-3-d registration for noninvasive pose identification of fracture fragments. IEEE Trans. Biomed. Eng. 58 (6) (2011) 1592-1601
  3. [11]11. Knaan, D., Joskowicz, L.: Effective intensity-based 2d/3d rigid registration between fluoroscopic x-ray and ct. In: Proc. Med. Image Comput. Comput.-Assist. Interv, Springer (2003) 351-358
  4. [12]12. Otake, Y., Armand, M., Armiger, R., Kutzer, M., Basafa, E., Kazanzides, P., Taylor, R.: Intraoperative image-based multi-view 2d/3d registration for imageguided orthopaedic surgery: Incorporation of fiducial-based c-arm tracking and gpu-acceleration. IEEE Trans. Med. Imag. 31 (4) (2012) 948-962
  5. [13]13. Krˇ cah, M., Sz´ ekely, G., Blanc, R.: Fully automatic and fast segmentation of the femur bone from 3d-ct images with no shape prior. In: Proc. IEEE Intl. Symp. Biomed. Imag. (2011) 2087-2090

Cited by

Sorted by citations

Authors
Grupp, R. B., Armand, M., & Taylor, R. H.
Affiliations
Johns Hopkins University (US)
Corresponding author
Grupp, Robert B.
Venue
Lecture Notes in Computer Science
Published
2018
Pages
153-163
ISSN
  • 0302-9743 (ISSN-L)
  • 1611-3349
OpenAlex
W2894976108
Cited by
23
References
0
Citations by year
2026: 3 · 2025: 7 · 2024: 4 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 2 · 2019: 1
FWCI
0.30
Type
conference paper
Language
en
Open access
Locations
  • Lecture notes in computer science (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
Keywords
periacetabular osteotomy, fluoroscopic navigation, intensity-based registration, computer-assisted surgery

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review