A New 2.5D Representation for Lymph Node Detection Using Random Sets of Deep Convolutional Neural Network Observations
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Automated Lymph Node (LN) detection is an important clinical diagnostic task but very challenging due to the low contrast of surrounding structures in Computed Tomography (CT) and to their varying sizes, poses, shapes and sparsely distributed locations. State-of-the-art studies show the performance range of 52.9% sensitivity at 3.1 false-positives per volume (FP/vol.), or 60.9% at 6.1 FP/vol. for mediastinal LN, by one-shot boosting on 3D HAAR features. In this paper, we first operate a preliminary candidate generation stage, towards ~100% sensitivity at the cost of high FP levels (~40 per patient), to harvest volumes of interest (VOI). Our 2.5D approach consequently decomposes any 3D VOI by resampling 2D reformatted orthogonal views N times, via scale, random translations, and rotations with respect to the VOI centroid coordinates. These random views are then used to train a deep Convolutional Neural Network (CNN) classifier. In testing, the CNN is employed to assign LN probabilities for all N random views that can be simply averaged (as a set) to compute the final classification probability per VOI. We validate the approach on two datasets: 90 CT volumes with 388 mediastinal LNs and 86 patients with 595 abdominal LNs. We achieve sensitivities of 70%/83% at 3 FP/vol. and 84%/90% at 6 FP/vol. in mediastinum and abdomen respectively, which drastically improves over the previous state-of-the-art work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visualizing and understanding convolutional networks
Zeiler, M. D., & Fergus, R. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10590-1_53 · Cited by 15,839 · cited 3×
“A recent approach proposes to visualize the trained CNN model by deconvolution and in order aid understanding the behavior of CNNs (Zeiler and Fergus, 2013).”
BackgroundMethodNew Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660
Mitosis Detection in Breast Cancer Histology Images with Deep Neural Networks
Cireşan, D. C., Giusti, A., Gambardella, L. M., & Schmidhuber, J. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40763-5_51 · Cited by 1,536 · cited 1×
“[11], and classifying digital pathology [12].”
Deep Feature Learning for Knee Cartilage Segmentation Using a Triplanar Convolutional Neural Network
Prasoon, A., Petersen, K., Igel, C., Lauze, F., Dam, E., & Nielsen, M. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40763-5_31 · Cited by 582 · cited 4×
“Studies that apply deep learning and CNNs to medical imaging applications also show promise, e.g. (Prasoon et al., 2013), and classifying digital pathology (Cirean et al., 2013).”
BackgroundMethodInfluentialConvolutional Networks Can Learn to Generate Affinity Graphs for Image Segmentation
Turaga, S. C., Murray, J. F., Jain, V., Roth, F., Helmstaedter, M., Briggman, K., Denk, W., & Seung, H. S. (2010) · Neural Computation · doi:10.1162/neco.2009.10-08-881 · Cited by 376 · cited 6×
“Extensions of CNNs to 3D have been proposed, but computational cost and memory consumption are still too high to be efficiently implemented on today’s computer graphics hardware units [11,13].”
BackgroundMethodInfluentialGokturk, S. B., Tomasi, C., Acar, B., Beaulieu, C. F., Paik, D. S., Jeffrey, R. B. J., Yee, J., & Napel, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974920 · Cited by 161
Automatic Detection and Segmentation of Lymph Nodes From CT Data
Barbu, A., Suehling, M., Xu, X., Liu, D., Zhou, S. K., & Comaniciu, D. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2168234 · Cited by 94 · cited 4×
“State-of-the-art methods (Barbu et al., 2012, Feulner et al., 2013) perform boosting-based feature selection and integration over a pool of ∼ 50 thousand 3D Haar-like features to obtain a strong binary classifier for detecting LNs. Due to the limited availability of annotated training data and the…”
BackgroundMethodResultInfluentialFeulner, J., Kevin Zhou, S., Hammon, M., Hornegger, J., & Comaniciu, D. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.11.001 · Cited by 72
Feuerstein, M., Glocker, B., Kitasaka, T., Nakamura, Y., Iwano, S., & Mori, K. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.05.005 · Cited by 43 · cited 1×
“…not directly comparable with the other studies since Barbu et al. (2012) reports on axillary, pelvic, and only some parts of the abdominal regions, while others evaluate only on me-diastinum (Feuerstein et al., 2012, Feulner et al., 2013, Feuerstein et al., 2009) or abdomen (Nakamura et al., 2013).”
ResultLiu, J., Zhao, J., Hoffman, J., Yao, J.-H., Zhang, W., Turkbey, E., Wang, S.-J., Kim, C. F., & Summers, R. (2014) · Medical Imaging · doi:10.1117/12.2043737 · Cited by 33
Self-citationAutomatic mediastinal lymph node detection in chest CT
Feuerstein, M., Deguchi, D., Kitasaka, T., Iwano, S., Imaizumi, K., Hasegawa, Y., Suenaga, Y., & Mori, K. (2009) · SPIE Proceedings · doi:10.1117/12.811101 · Cited by 28
Abdominal lymphadenopathy detection using random forest
Cherry, K. M., Wang, S., Turkbey, E. B., & Summers, R. M. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2043837 · Cited by 26
Self-citationNakamura, Y., Nimura, Y., Kitasaka, T., Mizuno, S., Furukawa, K., Goto, H., Fujiwara, M., Misawa, K., Ito, M., Nawano, S., et al. (2013) · Medical Imaging · doi:10.1117/12.2008282 · Cited by 12
Cited by
Wang, X., Peng, Y., Lu, L., Lu, Z., Bagheri, M., & Summers, R. M. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.369 · Cited by 4,616
“not limit to) an overview review on the future promise of deep learning [14] and a collection of important medical applications on lymph node and interstitial lung disease detection and classification [37,43]; cerebral microbleed detection [11]; pulmonary nodule detection in CT images [40]; automated pancreas segmentat…”
BackgroundInfluentialSelf-citationEfficient multi-scale 3D CNN with fully connected CRF for accurate brain lesion segmentation
Kamnitsas, K., Ledig, C., Newcombe, V. F. J., Simpson, J. P., Kane, A. D., Menon, D. K., Rueckert, D., & Glocker, B. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.10.004 · Cited by 3,498
Deep Learning Techniques for Medical Image Segmentation: Achievements and Challenges
Hesamian, M. H., Jia, W., He, X., & Kennedy, P. (2019) · Journal of Digital Imaging · doi:10.1007/s10278-019-00227-x · Cited by 1,631
Deep learning in bioinformatics
Min, S., Lee, B., & Yoon, S. (2016) · Briefings in Bioinformatics · doi:10.1093/bib/bbw068 · Cited by 1,465
Overview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,087
Metadata
- Authors
- Roth, H. R., Lu, L., Seff, A., Cherry, K. M., Hoffman, J., Wang, S., Liu, J., Turkbey, E., & Summers, R. M.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer International Publishing
- Published
- 2014
- Volume
- 17
- Issue
- Pt 1
- Pages
- 520-527
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W3105950366
- Cited by
- 340
- References
- 13
- FWCI
- 12.65
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.