Deep Learning, Sparse Coding, and SVM for Melanoma Recognition in Dermoscopy Images
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
This work presents an approach for melanoma recognition in dermoscopy images that combines deep learning, sparse coding, and support vector machine (SVM) learning algorithms. One of the beneficial aspects of the proposed approach is that unsupervised learning within the domain, and feature transfer from the domain of natural photographs, eliminates the need of annotated data in the target task to learn good features. The applied feature transfer also allows the system to draw analogies between observations in dermoscopic images and observations in the natural world, mimicking the process clinical experts themselves employ to describe patterns in skin lesions. To evaluate the methodology, performance is measured on a dataset obtained from the International Skin Imaging Collaboration, containing 2624 clinical cases of melanoma (334), atypical nevi (144), and benign lesions (2146). The approach is compared to the prior state-of-art method on this dataset. Two-fold cross-validation is performed 20 times for evaluation (40 total experiments), and two discrimination tasks are examined: 1) melanoma vs. all non-melanoma lesions, and 2) melanoma vs. atypical lesions only. The presented approach achieves an accuracy of 93.1% (94.9% sensitivity, and 92.8% specificity) for the first task, and 73.9% accuracy (73.8% sensitivity, and 74.3% specificity) for the second task. In comparison, prior state-of-art ensemble modeling approaches alone yield 91.2% accuracy (93.0% sensitivity, and 91.0% specificity) first the first task, and 71.5% accuracy (72.7% sensitivity, and 68.9% specificity) for the second. Differences in performance were statistically significant (p $$<$$ 0.05), suggesting the proposed approach is an effective improvement over prior state-of-art.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Caffe: Convolutional Architecture for Fast Feature Embedding
Jia, Y., Shelhamer, E., Donahue, J., Karayev, S., Long, J., Girshick, R., Guadarrama, S., & Darrell, T. (2014) · Proceedings of the 22nd ACM international conference on Multimedia · doi:10.1145/2647868.2654889 · Cited by 11,077
How transferable are features in deep neural networks?
Yosinski, J., Clune, J., Bengio, Y., & Lipson, H. (2014) · arXiv · doi:10.48550/arxiv.1411.1792 · Cited by 6,061
Diagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349
PH2 - A dermoscopic image database for research and benchmarking
Mendonca, T., Ferreira, P. M., Marques, J. S., Marcal, A. R. S., & Rozeira, J. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610779 · Cited by 1,009
Automated melanoma recognition
Ganster, H., Pinz, P., Rohrer, R., Wildling, E., Binder, M., & Kittler, H. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.918473 · Cited by 631
Two Systems for the Detection of Melanomas in Dermoscopy Images Using Texture and Color Features
Barata, C., Ruela, M., Francisco, M., Mendonca, T., & Marques, J. S. (2014) · IEEE Systems Journal · doi:10.1109/jsyst.2013.2271540 · Cited by 453
Dermoscopy of pigmented skin lesions
Braun, R. P., Rabinovitz, H. S., Oliviero, M., Kopf, A. W., & Saurat, J.-H. (2005) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2001.11.001 · Cited by 400
Sparse Modeling for Image and Vision Processing
Ponce, J., Mairal, J., Bach, F., Image, S. M., Processing, V., Hal, H. I., & Supérieure, E. N. (2014) · Cited by 335
Sparse Modeling for Image and Vision Processing
Mairal, J. (2014) · now publishers, Inc. eBooks · doi:10.1561/9781680830095 · Cited by 322
Computer-Aided Diagnosis of Melanoma Using Border- and Wavelet-Based Texture Analysis
Garnavi, R., Aldeen, M., & Bailey, J. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2212282 · Cited by 207
Self-citationFirst Prospective Study of the Recognition Process of Melanoma in Dermatological Practice
Gachon, J., Beaulieu, P., Sei, J. F., Gouvernet, J., Claudel, J. P., Lemaitre, M., Richard, M. A., & Grob, J. J. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.4.434 · Cited by 184
Automatic detection of blue-white veil and related structures in dermoscopy images
Celebi, M. E., Iyatomi, H., Stoecker, W. V., Moss, R. H., Rabinovitz, H. S., Argenziano, G., & Soyer, H. P. (2008) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2008.08.003 · Cited by 173
Carli, P., Quercioli, E., Sestini, S., Stante, M., Ricci, L., Brunasso, G., & DE Giorgi, V. (2003) · British Journal of Dermatology · doi:10.1046/j.1365-2133.2003.05023.x · Cited by 132
Ali, A.-R. A., & Deserno, T. M. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.912389 · Cited by 113
Multi-scale Color Local Binary Patterns for Visual Object Classes Recognition
Zhu, C., Bichot, C., & Chen, L. (2010) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2010.751 · Cited by 107
Dermatoscopia: o método de análise de padrões
Rezze, G. G., de Sá, B. C. S., & Neves, R. I. (2006) · Anais Brasileiros de Dermatologia · doi:10.1590/s0365-05962006000300009 · Cited by 56
Automatic Detection of Blue-White Veil by Discrete Colour Matching in Dermoscopy Images
Madooei, A., Drew, M. S., Sadeghi, M., & Atkins, M. S. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40760-4_57 · Cited by 36
A generalized framework for medical image classification and recognition
Abedini, M., Codella, N., Connell, J. H., Garnavi, R., Merler, M., Pankanti, S., Smith, J. R., & Syeda-Mahmood, T. F. (2015) · IBM Journal of Research and Development · doi:10.1147/jrd.2015.2390017 · Cited by 32
Self-citationA colour image processing method for melanoma detection
Colot, O., Devinoy, R. H., Sombo, A., & Brucq, D. D. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056241 · Cited by 25
Automated Medical Image Modality Recognition by Fusion of Visual and Text Information
Codella, N., Connell, J. H., Pankanti, S., Merler, M., & Smith, J. R. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-10470-6_61 · Cited by 12
Self-citation
Cited by
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
“Codella et al. (2015) Melanoma detection in dermoscopic images CNN Features from pre-trained CNN combined with”
MethodDermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362
Codella, N. C. F., Gutman, D., Celebi, M. E., Helba, B., Marchetti, M. A., Dusza, S. W., Kalloo, A., Liopyris, K., Mishra, N., Kittler, H., et al. (2018) · 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018) · doi:10.1109/isbi.2018.8363547 · Cited by 2,620
Self-citationAutomated Melanoma Recognition in Dermoscopy Images via Very Deep Residual Networks
Yu, L., Chen, H., Dou, Q., Qin, J., & Heng, P.-A. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2642839 · Cited by 1,140
Skin Lesion Analysis towards Melanoma Detection Using Deep Learning Network
Li, Y., & Shen, L. (2018) · Sensors · doi:10.3390/s18020556 · Cited by 634
Metadata
- Authors
- Codella, N., Cai, J., Abedini, M., Garnavi, R., Halpern, A., & Smith, J. R.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer International Publishing
- Published
- 2015
- Pages
- 118-126
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W2180648740
- Cited by
- 379
- References
- 20
- FWCI
- 151.73
- Type
- conference paper
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.