Critical States Distance Filter Based Approach for Detection and Blockage of Cyberattacks in Industrial Control Systems
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The methodology proposed by [13] is a deepening of [40] from the same author.
“This is a deepening of [40] from the same author.”
From A Review of Cybersecurity Guidelines for Manufacturing Factories in Industry 4.0 (2021) · cites this paper as [40]
The ICS network can be divided into three levels: Level 0 operative part with sensors/actuators, Level 1 control part with PLC/HMI, and Level 2 supervision with control room/SCADA.
“The ICS network can be divided into three levels [40], [41]:”
From A Review of Cybersecurity Guidelines for Manufacturing Factories in Industry 4.0 (2021) · cites this paper as [40]
Cites
Guide to Industrial Control Systems (ICS) Security
Stouffer, K., Pillitteri, V., Lightman, S., Abrams, M., & Hahn, A. (2015) · doi:10.6028/nist.sp.800-82r2 · Cited by 1,377 · see citing works
Cyber physical systems security: analysis, challenges and solutions
Ashibani, Y., & Mahmoud, Q. H. (2017) · Computers & Security · doi:10.1016/j.cose.2017.04.005 · Cited by 447 · see citing works
Accurate modeling of modbus/TCP for intrusion detection in SCADA systems
Goldenberg, N., & Wool, A. (2013) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2013.05.001 · Cited by 323 · see citing works
Critical State-Based Filtering System for Securing SCADA Network Protocols
Nai Fovino, I., Coletta, A., Carcano, A., & Masera, M. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2181132 · Cited by 108 · see citing works
False sequential logic attack on SCADA system and its physical impact analysis
Li, W., Xie, L., Deng, Z., & Wang, Z. (2016) · Computers & Security · doi:10.1016/j.cose.2016.01.001 · Cited by 71 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A Review of Cybersecurity Guidelines for Manufacturing Factories in Industry 4.0
Mullet, V., Sondi, P., & Ramat, E. (2021) · IEEE Access · doi:10.1109/access.2021.3056650 · Cited by 161 · see citing works
“The ICS network can be divided into three levels [40], [41]: Level 0: Operative part with sensors/actuators; Level 1: Control part with PLC/HMI; Level 2: Supervision with control room/SCADA; IT solutions such as firewall/DMZ are usually used in the level 2 and higher to protect from DDoS attacks or…”
BackgroundExploiting the temporal behavior of state transitions for intrusion detection in ICS/SCADA
Kabasele Ndonda, G., & Sadre, R. (2022) · IEEE Access · doi:10.1109/access.2022.3213080 · Cited by 8 · see citing works
- Authors
- Sicard, F., Zamai, É., & Flaus, J.-M.
- Affiliations
- Institut polytechnique de Grenoble (FR)
- Corresponding author
- Sicard, Franck
- ORCID
- Sicard, Franck
- Venue
- Diagnosability, Security and Safety of Hybrid Dynamic and Cyber-Physical Systems
- Publisher
- Springer International Publishing
- Published
- 2018
- Pages
- 117-145
- OpenAlex
- W2790110093
- Cited by
- 10
- References
- 5
- Citations by year
- 2024: 2 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 3
- FWCI
- 5.29
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Springer eBooks (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Security and Intrusion Detection
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- industrial control systems, cyberattack detection, intrusion detection systems, attack blocking, critical infrastructure security
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review