Cited by 71Smart Grid Security and ResilienceInformation and Cyber SecurityIndustrial Automation and Control Systems

False sequential logic attack on SCADA system and its physical impact analysis

Li, Weize, Xie, Lun, Deng, Zulan, Wang, Zhiliang·2016·Computers & Security

Integrity signals

Registry

Crossref · 10.1016/j.cose.2016.01.001

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Test beds can be realised as simple simulation based, federated simulation, or emulation/implementation based.

    “Test beds could be realised [54] as simple simulation based (TrueTime), federated simulation (several dedicated simulation federates for plant, network etc. such as HLA) or emulation/implementation based (real hardware or emulator such as EmuLab).”

Cites

Flagged first, then by citations

1 of the 34 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Li, W., Xie, L., Deng, Z., & Wang, Z.
Affiliations
University of Science and Technology Beijing (CN)
Corresponding author
Xie, Lun
Venue
Computers & Security
Publisher
Elsevier BV
Published
2016-05
Volume
58
Pages
149-159
ISSN
0167-4048 (ISSN-L)
OpenAlex
W2277630828
Cited by
71
References
34
Citations by year
2026: 5 · 2024: 6 · 2023: 7 · 2022: 6 · 2021: 9 · 2020: 8 · 2019: 7 · 2018: 15 · 2017: 8
FWCI
8.41
Type
journal article
Language
en
Open access
closed
Locations
Computers & Security (publishedVersion)
Funders
  • National Key Technologies R&D Program of China (2014BAF08B04)
  • National Natural Science Foundation of China (61170115, 61432004)
  • Foundation of Beijing Engineering and Technology Center for Convergence Networks and Ubiquitous Services
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
  • Physical Sciences › Computer Science › Information Systems › Information and Cyber Security
  • Physical Sciences › Engineering › Control and Systems Engineering › Industrial Automation and Control Systems
Keywords
SCADA systems, cyber-physical attacks, attack modeling, industrial control security

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review