Automatic Segmentation and Disease Classification Using Cardiac Cine MR Images
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Segmentation of the heart in cardiac cine MR is clinically used to quantify cardiac function. We propose a fully automatic method for segmentation and disease classification using cardiac cine MR images. A convolutional neural network (CNN) was designed to simultaneously segment the left ventricle (LV), right ventricle (RV) and myocardium in end-diastole (ED) and end-systole (ES) images. Features derived from the obtained segmentations were used in a Random Forest classifier to label patients as suffering from dilated cardiomyopathy, hypertrophic cardiomyopathy, heart failure following myocardial infarction, right ventricular abnormality, or no cardiac disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation
Milletari, F., Navab, N., & Ahmadi, S.-A. (2016) · 2016 Fourth International Conference on 3D Vision (3DV) · doi:10.1109/3dv.2016.79 · Cited by 11,931 · cited 1×
“ined for both images by assigning the class with the highest probability to each voxel. The trainable parameters in the CNN were optimized using a loss function based on the Dice similarity coecient [7]. This partly corrects for class imbalance in the voxel labels. A soft Dice loss was used, Dice c = P N i R c(i)A c(i…”
MethodMulti-scale context aggregation by dilated convolutions
Yu, F., & Koltun, V. (2015) · arXiv · doi:10.48550/arxiv.1511.07122 · Cited by 7,738 · cited 1×
“ES. These are combined into two multi-class segmentations. 3.1 Segmentation A CNN was trained to segment the LV cavity, the RV cavity, and the myocardium in 2D short-axis cine MR slices. Motivated by [13,12], the network was designed to contain a number of convolutional layers with increasing levels of dilation. This…”
MethodInfluentialA Fully Convolutional Neural Network for Cardiac Segmentation in Short-Axis MRI
Tran, P. V. (2016) · arXiv · doi:10.48550/arxiv.1604.00494 · Cited by 323
Cited by
Bernard, O., Lalande, A., Zotti, C., Cervenansky, F., Yang, X., Heng, P.-A., Cetin, I., Lekadir, K., Camara, O., Gonzalez Ballester, M. A., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2837502 · Cited by 2,431
“[50] is the only team that implemented a CNN without an encoder-decoder architecture.”
BackgroundMethodInfluentialSelf-citationConfidence calibration and predictive uncertainty estimation for deep medical image segmentation
Mehrtash, A., Wells, W. M., Tempany, C. M., Abolmaesumi, P., & Kapur, T. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3006437 · Cited by 428
“For heart ventricle segmentation, data from the MICCAI 2017 ACDC challenge for automated cardiac diagnosis was used [39].”
MethodLearning Active Contour Models for Medical Image Segmentation
Chen, X., Williams, B. M., Vallabhaneni, S. R., Czanner, G., Williams, R., & Zheng, Y. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.01190 · Cited by 334
Machine learning in cardiovascular magnetic resonance: basic concepts and applications
Leiner, T., Rueckert, D., Suinesiaputra, A., Baeßler, B., Nezafat, R., Išgum, I., & Young, A. A. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0575-y · Cited by 282
Self-citation3-D Consistent and Robust Segmentation of Cardiac Images by Deep Learning With Spatial Propagation
Zheng, Q., Delingette, H., Duchateau, N., & Ayache, N. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2820742 · Cited by 202
Metadata
- Authors
- Wolterink, J. M., Leiner, T., Viergever, M. A., & Išgum, I.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer International Publishing
- Published
- 2018
- Pages
- 101-110
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W2744730369
- Cited by
- 122
- References
- 4
- FWCI
- 3.77
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.