Efficient Semiautomatic Segmentation of 3D Objects in Medical Images
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Survey: interpolation methods in medical image processing
Lehmann, T. M., Gonner, C., & Spitzer, K. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816070 · Cited by 1,340 · cited 1×
“Interpolation techniques [12] are used for many applications in medical imaging, e.”
MethodMorphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265 · cited 1×
“which is equal to 1 minus the similarity index [16].”
BackgroundDistance transformations in arbitrary dimensions
Borgefors, G. (1984) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(84)90035-5 · Cited by 779 · cited 1×
“The distance transformation can be calculated efficiently with a version of the city-block distance [13] or, as in our implementation, with two consecutive chamfering processes [14, 15 ] realized with 3×3-kernel operations.”
MethodIntelligent scissors for image composition
Mortensen, E. N., & Barrett, W. A. (1995) · Proceedings of the 22nd annual conference on Computer graphics and interactive techniques - SIGGRAPH '95 · doi:10.1145/218380.218442 · Cited by 778
Constraints on deformable models:Recovering 3D shape and nonrigid motion
Terzopoulos, D., Witkin, A., & Kass, M. (1988) · Artificial Intelligence · doi:10.1016/0004-3702(88)90080-x · Cited by 774 · cited 1×
“Although snakes have a direct three-dimensional extension introduced as balloons [ 2 ] the propagation of an initial two-dimensional snake over the slices and subsequent adjustment is preferred in most applications for reasons of robustness and practicability.”
BackgroundUser-Steered Image Segmentation Paradigms: Live Wire and Live Lane
Falcão, A. X., Udupa, J. K., Samarasekera, S., Sharma, S., Hirsch, B. E., & Lotufo, R. D. A. (1998) · Graphical Models and Image Processing · doi:10.1006/gmip.1998.0475 · Cited by 481 · cited 2×
“The cost function used for the test was identical for all images and was based on a Sobel-like gradient function (feature f5 in [10] extended to 8-neighborhood) and the gray values at the object border with relative weights of 0.”
BackgroundMethodShape-based interpolation of multidimensional objects
Raya, S. P., & Udupa, J. K. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52980 · Cited by 435 · cited 2×
“The distance transformation can be calculated efficiently with a version of the city-block distance [13] or, as in our implementation, with two consecutive chamfering processes [14,15] realized with 3×3-kernel operations.”
MethodInteractive live-wire boundary extraction
Barrett, W. A., & Mortensen, E. N. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85005-0 · Cited by 334
An ultra-fast user-steered image segmentation paradigm: live wire on the fly
Falcao, A. X., Udupa, J. K., & Miyazawa, F. K. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.832960 · Cited by 275 · cited 2×
“Several modifications of the basic approach including quality studies have been published [8–11], proving the high accuracy, efficiency, and reproducibility of the algorithm.”
BackgroundMethodAdaptive boundary detection using 'live-wire' two-dimensional dynamic programming
Mortensen, E. N., Morse, B., Barrett, W. A., & Udupa, J. K. (2003) · Computers in cardiology · doi:10.1109/cic.1992.269378 · Cited by 120 · cited 1×
“Another promising approach to interactive boundary detection in two-dimensional images is the live wire algorithm, also known as intelligent scissors, which was first introduced in 1992 [4,5].”
BackgroundBoundary detection via dynamic programming
Udupa, J. K., Samarasekera, S., & Barrett, W. A. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.131065 · Cited by 50 · cited 1×
“Another promising approach to interactive boundary detection in two-dimensional images is the live wire algorithm, also known as intelligent scissors, which was first introduced in 1992 [4,5].”
BackgroundVisualization in Biomedical Computing 1994
Robb, R. A. (1992) · Cited by 48
Fast, accurate, and reproducible live-wire boundary extraction
Barrett, W. A., & Mortensen, E. N. (1996) · Lecture notes in computer science · doi:10.1007/bfb0046953 · Cited by 47 · cited 2×
“Our live wire approach is provided with the additional concepts of boundary snapping, data-driven cooling for automated generation of seed points and learning of cost function parameters [6,8].”
BackgroundMethodInteraction Techniques and Vessel Analysis for Preoperative Planning in Liver Surgery
Preim, B., Selle, D., Spindler, W., Oldhafer, K. J., & Peitgen, H. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_62 · Cited by 29 · cited 1×
“It is part of an ongoing clinical project for the approximation of patient-specific organ segments and preoperative planning of surgery [17,18].”
BackgroundSelf-citationUltrafast user-steered image segmentation paradigm: live-wire-on-the-fly
Falcão, A. X., Udupa, J. K., & Miyazawa, F. K. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.348573 · Cited by 19
Cited by
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
The Liver Tumor Segmentation Benchmark (LiTS)
Bilic, P., Christ, P., Li, H. B., Vorontsov, E., Ben-Cohen, A., Kaissis, G., Szeskin, A., Jacobs, C., Mamani, G. E. H., Chartrand, G., et al. (2023) · Medical Image Analysis · doi:10.1016/j.media.2022.102680 · Cited by 1,412
“Further, 2D to 3D interpolation methods based on shape models to reconstruct the whole 3D surface based on selected 2D contours [65, 66], and slice based segmentation using distance transformations of manual segmented upper and lower axial slices[67] are proposed.”
MethodSelf-citationThe Liver Tumor Segmentation Benchmark (LiTS)
Bilic, P., Christ, P., Li, H. B., Vorontsov, E., Ben-Cohen, A., Kaissis, G., Szeskin, A., Jacobs, C., Mamani, G. E. H., Chartrand, G., et al. (2019) · arXiv · doi:10.48550/arxiv.1901.04056 · Cited by 1,412
Self-citationGosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
“The in-house software iSeg (Neufeld 2008) (ZMT Zurich MedTech AG, Switzerland) was used to identify the pixels belonging to different tissues (figure 3). iSeg offers a large number of image processing algorithms, such as Live Wire (Schenk et al 2000), Level Sets (Suri et al 2002), Region Growing (Hamerly and Elkan 200…”
MethodAnalysis of vasculature for liver surgical planning
Selle, D., Preim, B., Schenk, A., & Peitgen, H.-O. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801166 · Cited by 448
“The required time can be shortened by some 70% (depending on the slice distance, up to 85% for high-resolution multislice CT data) [ 40 ], [41].”
BackgroundSelf-citation
Metadata
- Authors
- Schenk, A., Prause, G., & Peitgen, H.-O.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer Berlin Heidelberg
- Published
- 2000
- Pages
- 186-195
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W1488765683
- Cited by
- 174
- References
- 17
- FWCI
- 8.02
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.