Point spread function analysis of magnetic particles
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Contrast generation in MPI critically depends on parameters that affect the magnetization response, such as SPION size and size distribution.
“As an important note, contrast generation in MPI critically depends on the parameters that affect the magnetization response like SPION size and size distribution [113, 114].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [113]
Cites
Oxley, J. A. (1995) · Medical Entomology and Zoology · Cited by 753 · see citing works
Validity limits of the Néel relaxation model of magnetic nanoparticles for hyperthermia
Hergt, R., Dutz, S., & Zeisberger, M. (2009) · Nanotechnology · doi:10.1088/0957-4484/21/1/015706 · Cited by 198 · see citing works
PARTICLE DYNAMICS OF MONO-DOMAIN PARTICLES IN MAGNETIC PARTICLE IMAGING
Weizenecker, J., Gleich, B., Rahmer, J., et al. (2010) · doi:10.1142/9789814324687_0001 · Cited by 24 · see citing works
Self-citationThe impact of filtering direct-feedthrough on the x-space theory of magnetic particle imaging
Lu, K., Goodwill, P. W., Zheng, B., et al. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.878446 · Cited by 11 · see citing works
The x-space formulation of magnetic particle imaging including non-negligible relaxation effects
Croft, L. R., Goodwill, P. W., Tamrazian, A., et al. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.878418 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181 · see citing works
Magnetic particle imaging with tailored iron oxide nanoparticle tracers
Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Arami, H., Saritas, E. U., Croft, L. R., Konkle, J., Goodwill, P. W., Halkola, A., Rahmer, J., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2375065 · Cited by 222 · see citing works
Self-citation
- Authors
- Schmale, I., Rahmer, J., Gleich, B., Borgert, J., & Weizenecker, J.
- Affiliations
- Philips (Germany) (DE)
- Karlsruhe University of Applied Sciences (DE)
- Corresponding author
- Schmale, Ingo
- Venue
- Springer proceedings in physics
- Publisher
- Springer Berlin Heidelberg
- Published
- 2012
- Pages
- 287-292
- ISSN
- 0930-8989 (ISSN-L)
- 1867-4941
- OpenAlex
- W49616149
- Cited by
- 17
- References
- 5
- Citations by year
- 2026: 1 · 2025: 1 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 4 · 2015: 3 · 2014: 2 · 2013: 2
- FWCI
- 6.68
- Type
- book chapter
- Language
- en
- Open access
- closed
- Licence
- Locations
- Springer proceedings in physics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Geomagnetism and Paleomagnetism Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- point spread function, magnetic particles, magnetization behavior, magnetization curves, magnetic hysteresis, Resovist
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review