Load transfer through chain molecules after interpenetration at interfaces
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Jud and Kausch (1979) tested compact tension specimens made of PMMA with dimensions 26 mm width and height, 3 mm thickness, and an initial notch 0.5 mm wide and 12 mm long.
“Their CT specimens measured 26 mm in width and height, with a thickness of 3 mm, and contained an initial notch 0.5 mm wide and 12 mm long (see Figure 11a).”
From A thermodynamically consistent mixed-mode cohesive zone model for fracture of self-healing materials (2026) · cites this paper as Jud and Kausch (1979)
Because Jud and Kausch (1979) did not report load-displacement curves nor fracture energy values, and no suitable additional data were found, the fracture parameters for PMMA were estimated based on typical values for PMMA and engineering judgment.
“Because Jud and Kausch (1979) did not report load-displacement curves nor fracture energy values, and no suitable additional data were found in the literature for similar CT tests, the fracture parameters were estimated based on typical values for PMMA and engineering judgment.”
From A thermodynamically consistent mixed-mode cohesive zone model for fracture of self-healing materials (2026) · cites this paper as Jud and Kausch (1979)
Jud and Kausch (1979) report values of the mode-I K-calibration factor Y ranging between 11 and 16 for their CT specimens.
“Jud and Kausch (1979) report values of Y ranging between 11 and 16 for their CT specimens.”
From A thermodynamically consistent mixed-mode cohesive zone model for fracture of self-healing materials (2026) · cites this paper as Jud and Kausch (1979)
The model's numerical predictions closely match the experimental values reported by Jud and Kausch (1979) for PMMA compact tension tests.
“As shown, our numerical predictions (solid line) closely match the experimental values (dots) reported by Jud and Kausch (1979)”
From A thermodynamically consistent mixed-mode cohesive zone model for fracture of self-healing materials (2026) · cites this paper as Jud and Kausch (1979)
Jud and Kausch (1979) only reported fracture toughness values.
“Jud andKausch (1979) only reported fracture toughness values.”
From A thermodynamically consistent mixed-mode cohesive zone model for fracture of self-healing materials (2026) · cites this paper as Jud and Kausch (1979)
Cited by
Sorted by citations
Autonomic healing of polymer composites
White, S. R., Sottos, N. R., Geubelle, P. H., Moore, J. S., Kessler, M. R., Sriram, S. R., Brown, E. N., & Viswanathan, S. (2001) · Nature · doi:10.1038/35057232 · Cited by 4,575 · see citing works
A chiroselective peptide replicator
Saghatelian, A., Yokobayashi, Y., Soltani, K., & Ghadiri, M. R. (2001) · Nature · doi:10.1038/35057238 · Cited by 310 · see citing works
Nji, J., & Li, G. (2012) · Smart Materials and Structures · doi:10.1088/0964-1726/21/2/025011 · Cited by 96 · see citing works
Alsheghri, A. A., & Abu Al-Rub, R. K. (2016) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2016.06.010 · Cited by 37 · see citing works
Thermodynamic-based cohesive zone healing model for self-healing materials
Alsheghri, A. A., & Abu Al-Rub, R. K. (2015) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2015.10.003 · Cited by 31 · see citing works
A thermodynamically consistent mixed-mode cohesive zone model for fracture of self-healing materials
Giraldo-Londoño, O., Spring, D. W., Muñetón-López, R. A., & Paulino, G. H. (2026) · doi:10.2139/ssrn.7528848
- Authors
- Jud, K., & Kausch, H. H.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- ORCID
- Kausch, H.H.
- Venue
- Polymer Bulletin
- Published
- 1979-09
- Volume
- 1
- Issue
- 10
- ISSN
- 0170-0839 (ISSN-L)
- 1436-2449
- OpenAlex
- W2035816177
- Cited by
- 164
- References
- 0
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 4 · 2023: 3 · 2022: 4 · 2021: 9 · 2020: 6 · 2019: 4 · 2018: 4 · 2017: 2 · 2016: 11 · 2015: 12 · 2014: 8 · 2013: 10 · 2012: 6
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Polymer Bulletin (publishedVersion)
- Funders
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Topics
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer composites and self-healing
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
- Physical Sciences › Engineering › Mechanical Engineering › Epoxy Resin Curing Processes
- Keywords
- crack healing, PMMA, fracture toughness, glass transition, chain molecules, molecular weight
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review