PreprintCited by 0Polymer composites and self-healingMechanical Behavior of CompositesNumerical methods in engineering

A thermodynamically consistent mixed-mode cohesive zone model for fracture of self-healing materials

Open access
Giraldo-Londoño, Oliver, Spring, Daniel W., Muñetón-López, Rogelio Andrés, Paulino, Glaucio H.·2026·SSRN Electronic Journal

Abstract

Although significant progress has been made in engineering intrinsic self-healing materials, modeling arbitrary fracture-healing events within a computational fracture mechanics framework remains challenging. Existing cohesive-healing formulations are often restricted to mode-I fracture or do not provide a thermodynamically consistent treatment of healing under general mixed-mode loading. To address these limitations, we extend the Park-Paulino-Roesler cohesive zone model (CZM) and introduce a thermodynamically consistent mixed-mode cohesive-healing model with mode-dependent healing kinetics. Our model introduces two internal state variables representing the maximum effective crack opening displacements in the normal and tangential directions, which evolve according to healing kinetics activated only when crack faces are in contact and at rest. This approach enables the recovery of mode-I and mode-II cohesive properties and provides a unified description of loading, unloading, healing, and reloading, with damage recovery occurring exclusively during rest periods. We demonstrate that the model is thermodynamically consistent and implement it in a finite element framework. We conduct single-element tests under mode-I and mixed-mode conditions and show that the model predicts damage and healing evolutions that align with theoretical expectations. We further validate the model against experimental data from fracture-healing tests on self-healing asphalt mastics and polymethyl methacrylate (PMMA). The results demonstrate that the model can predict recovery of strength and fracture toughness as functions of time and temperature. Finally, we conduct mixed-mode bending simulations to demonstrate how mode-dependent healing kinetics and local mixed-mode history govern spatially non-uniform damage recovery and the resulting structural response. Together, these results demonstrate that our cohesive-healing model provides a versatile and predictive framework for simulating fracture and healing in self-healing materials under general loading conditions.

AI snapshot

Written from the paper’s full text.

TL;DR

The paper extends the Park-Paulino-Roesler cohesive zone model into a thermodynamically consistent mixed-mode cohesive-healing model with mode-dependent healing kinetics that activate only when crack faces are in contact and at rest. It verifies the formulation with single-element tests and validates it against fracture-healing experiments on asphalt mastics and PMMA, plus mixed-mode bending simulations.

Key findings

  • The model introduces two internal state variables for maximum effective normal and tangential crack openings, with healing variables \(h_n\) and \(h_t\); healing occurs only during full rest when \(\Delta_n=\Delta_t=0\) and their rates are zero. Thermodynamic consistency is demonstrated through the Clausius-Duhem inequality, and the healing kinetics can be recast in Onsager form.
  • Single-element tests under pure mode-I, proportional mixed-mode, and non-proportional mixed-mode loading show that \(h_n\), \(h_t\), effective damage parameters \(d_n\), \(d_t\), and cohesive tractions evolve as theoretically expected; healing variables increase only during full rest, and reloading shows stiffness and strength recovery.
  • Validation against asphalt mastic dogbone tests (Qiu et al., 2012) at 20°C predicts slow healing-strength-ratio increase for rest times under 1 h, rapid near-exponential increase thereafter, and saturation once \(H_P\) exceeds approximately 60%. Calibrated parameters were \(\chi_n=\chi_t=0.5895\ \text{h}^{-1}\), \(\xi_n=\xi_t=2.57\) for PBmas and \(\chi_n=\chi_t=0.5947\ \text{h}^{-1}\), \(\xi_n=\xi_t=3.71\) for SBSmas, with the higher SBS exponent producing slower healing.
  • Three-point bending simulations (García, 2012) capture temperature-dependent healing, predicting full strength recovery in under 2 minutes at 110°C and only partial recovery after 30 h at 30°C. PMMA compact tension simulations (Jud and Kausch, 1979) reproduce rapid early fracture-toughness recovery and later plateau, with calibrated \(\chi_n=\chi_t=0.667\ \text{min}^{-1}\) and \(\xi_n=\xi_t=2.741\). In mixed-mode bending, healing strength ratio increases monotonically with rest time and approaches complete recovery; increasing \(\chi_n/\chi_t\) shifts recovery to shorter rest times, and local damage recovery is spatially nonuniform and state-dependent.

Methods

  • The formulation extends the thermodynamically consistent PPR cohesive zone model of Spring et al. (2016). It splits Helmholtz free energy into mechanical and chemical parts, defines effective tractions \(T_n=(1-d_n)E_n\Delta_n\) and \(T_t=(1-d_t)E_t\Delta_t\), and uses healing kinetics \(\dot h_n=\chi_n(1-h_n)^{\xi_n}[1-H(\Delta_n)]\) during rest periods, with an exact time integration scheme for rest periods. A finite element implementation is derived with internal force vectors and tangent stiffness matrices for cohesive-healing elements.
  • Verification uses single cohesive element tests under pure mode-I, proportional mixed-mode, and non-proportional mixed-mode loading. Table 1 parameters include mode-I and mode-II fracture energies of 2.8 N/mm, normal and tangential cohesive strengths of 1.5 MPa, shape parameters \(\alpha=3.5\), \(\beta=2.5\), and initial slope indicators \(\lambda_n=\lambda_t=0.25\).
  • Validation uses a Matlab finite element implementation against three experimental datasets: Qiu et al. (2012) asphalt mastic dogbone specimens, García (2012) notched asphalt mastic beams, and Jud and Kausch (1979) PMMA compact tension specimens, plus a mixed-mode bending simulation. Fracture parameters were manually calibrated to initial fracture response; healing parameters were determined by inverse analysis using a least-squares technique with non-negativity constraints, assuming \(\chi_n=\chi_t\) and \(\xi_n=\xi_t\) due to limited experimental data.

Limitations

  • The paper states that it assumes \(\chi_n=\chi_t\) and \(\xi_n=\xi_t\) because of limited experimental data, and notes this assumption could be relaxed if independent measures of shear healing become available. For PMMA, Jud and Kausch (1979) did not report load-displacement curves or fracture energy values, so fracture parameters were estimated from typical PMMA values and engineering judgment. For SBSmas, experimental load-displacement curves were not reported, so the same fracture parameters calibrated for PBmas were used.
  • For the three-point bending simulations, the applied loading-unloading-reloading rates differ from the experimental 0.01 mm/s rate because the bulk material is assumed elastic; time during those phases is treated as pseudo-time, with real-time considerations applied only during rest periods. At 40°C, limited experimental data—especially between approximately 10 and 90 hours—limited calibration of early-stage healing, and at 30°C the anomalously high calibrated healing viscosity is attributed to the large healing exponent at that temperature.
  • Evident from the text: there is no experimental mixed-mode fracture-healing data, so the mixed-mode bending study is a simulation rather than experimental validation. The healing kinetics are described as a heuristic rule mimicking more accurate polymer-chain-dynamics models, not a mechanistic model. The manuscript is also a preprint and has not been peer reviewed.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.2139/ssrn.7528848

Cites

0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

5 of 35 cited sources checked · 2 supported · 0 flagged · accuracy not yet measured

  • Premisecitation

    Sigmoidal strength recovery curves were obtained from experiments on self-healing ceramic materials, asphalt concrete, microcapsule-based self-healing materials, and hydrogels.

    “For example, sigmoidal strength recovery curves were obtained from experiments conducted on self-healing ceramic materials (Ozaki et al., 2016(Ozaki et al., , 2020)), asphalt concrete (García, 2012;Qiu et al., 2012), microcapsule-based self-healing materials (Zwaag, 2008), and hydrogels (Wang et al., 2017;Yu et al., 2018).”
    Quote in the paperSubstantial claim1 of 3 sources checked
    • cites Ozaki et al., 2016 source

      Section 3.2 compares healing-time-dependent strength recovery in self-healing ceramics with experimental results reported by Osada et al. (2009). Our copy does not describe those experimental curves as sigmoidal, so it supports the experimental strength-recovery portion of the claim but not the specified curve shape. The other materials are attributed to other citations in the sentence. (LLM, conf=0.81)

      Experimental — accuracy not yet measured
    • cites García, 2012;Qiu et al., 2012

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites Zwaag, 2008 source
  • Interpretationcitation

    The sigmoid-like evolution of recovery ratios is consistent with experimental observations obtained for various self-healing materials.

    “which is consistent with experimental observations obtained for various self-healing materials.”
    Quote in the paperNot a substantial claim2 of 3 sources checked
    • cites Ozaki et al., 2016 source

      Section 3.2 (page unavailable) reports a qualitative agreement between modeled strength recovery over healing time and experimental results for alumina/SiC nanocomposites. It does not describe the observed recovery as sigmoid-like or establish that pattern across various self-healing materials. (LLM, conf=0.82)

      Experimental — accuracy not yet measured
    • cites Ozaki et al., 2020 source

      The 'Comparison with experimental results' section (page unavailable) reports that strength recovery increased with healing time in the FEA and in an experiment on self-healing ceramics. It does not describe sigmoid-like recovery ratios or establish that this pattern was observed across various self-healing materials. (LLM, conf=0.84)

      Experimental — accuracy not yet measured
    • cites García, 2012;Qiu et al., 2012

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Premisenone given

    Experimental load-displacement curves for the SBSmas specimens were not reported in Qiu et al. (2012).

    “Experimental load-displacement curves for the SBSmas specimens were not reported inQiu et al. (2012).”
    Quote in the paperSubstantial claim1 of 1 sources checked
    • cites Qiu et al. (2012) source
  • Findingown data

    The model can predict recovery of strength and fracture toughness as functions of time and temperature.

    “The results demonstrate that the model can predict recovery of strength and fracture toughness as functions of time and temperature.”
    Quote in the paperSubstantial claim
  • Findingown data

    Mixed-mode bending simulations demonstrate how mode-dependent healing kinetics and local mixed-mode history govern spatially non-uniform damage recovery and the resulting structural response.

    “Finally, we conduct mixed-mode bending simulations to demonstrate how mode-dependent healing kinetics and local mixed-mode history govern spatially non-uniform damage recovery and the resulting structural response.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. 21
  • May combine two claims. 57
  • The quote only partly states this claim. 1
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Similar healing evolution laws have been used in continuum damage-healing mechanics frameworks and in some existing cohesive-healing formulations.

    “Similar healing evolution laws have been used in the context of continuum damage-healing mechanics frameworks (e.g., seeDarabi et al., 2012) and for some existing cohesive-healing formulations (e.g., seeAlsheghri and Al-Rub, 2015, 2016).”
    Quote in the paperNot a substantial claim1 of 2 sources checked
    • cites Darabi et al., 2012 source
    • cites Alsheghri and Al-Rub, 2015, 2016

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Findingreasoning

    In the pure mode-I opening test, during initial stages of reloading both the healing variable and effective damage parameter remain constant, but after ∆n reaches κ_h_n, the healing variable starts to decrease and the effective damage parameter starts to increase until complete failure.

    “During the initial stages of reloading (between points C and D), both the healing variable and the effective damage parameter remain constant, but after ∆ n reaches κ h n , the healing variable starts to decrease and the effective damage parameter starts to increase until complete failure occurs.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    At 50°C, the healing curve follows a sigmoidal shape, with an initial lag period followed by rapid recovery, indicating a thermally activated healing process.

    “At 50 • C (Figure 10g), the healing curve follows a sigmoidal shape, with an initial lag period followed by rapid recovery, indicating a thermally activated healing process.”
    Quote in the paperNot a substantial claim
    • The authors state this as an assumption: The bulk material behaves elastically in the numerical models.
  • May combine two claims.

    Findingown data

    The SBSmas specimens have significantly higher healing exponent (ξ_n = ξ_t) than the PBmas specimens, while both mastics have nearly identical healing viscosity values (χ_n = χ_t).

    “Although both mastics have nearly identical healing viscosity values (χ n = χ t ), the SBSmas specimens have significantly higher healing exponent (ξ n = ξ t ) than the PBmas specimens.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: The bulk material behaves elastically in the numerical models.
  • May combine two claims.

    Findingown data

    In non-proportional mixed-mode loading, the effective damage parameters evolve in a staggered fashion due to asynchronous loading/unloading and show reductions only during the time window corresponding to full rest.

    “Moreover, Figure 8c shows that the effective damage parameters dn and dt evolve in a staggered fashion due to the asynchronous loading/unloading of ∆ n and ∆ t , and show reductions only during the time window corresponding to full rest.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The model accurately predicts full strength recovery in under 2 minutes at 110°C and only partial strength recovery even after 30 hours at 30°C.

    “In particular, our model accurately predicts full strength recovery in under 2 minutes at 110 • C and only partial strength recovery even after 30 hours at 30 • C.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: The bulk material behaves elastically in the numerical models.
  • May combine two claims.

    Findingown data

    For higher values of ξ_n, the healing process begins more slowly and the time required to reach near-saturation levels (e.g., 90-95% recovery) becomes significantly longer.

    “for higher values of ξ n , not only does the healing process begin more slowly, but the time required to reach nearsaturation levels (e.g., 90-95% recovery) becomes significantly longer.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    In proportional mixed-mode loading, the traction-separation responses show clear improvements in stiffness and peak tractions during reloading compared to initial loading, confirming partial recovery of mechanical strength due to healing.

    “The traction-separation responses (Figures 7d-e) show clear improvements in stiffness and peak tractions during reloading compared to initial loading, confirming the partial recovery of mechanical strength due to healing.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    In proportional mixed-mode loading, the effective damage parameters increase during loading, remain constant during unloading, decrease during the rest period, and increase again during reloading.

    “As shown in Figure 7c, the effective damage parameters increase during loading (up until A), remain constant during unloading (between A and B), decrease during the rest period (between B and C), and increase again during reloading (after D) as new damage accumulates.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The healing viscosity parameters (χ_n = χ_t) generally increase with temperature, which agrees with the experimentally observed increase in healing rate with temperature.

    “Notably, the healing viscosity parameters (χ n = χ t ) generally increase with temperature, which agrees with the experimentally observed increase in healing rate with temperature.”
    Quote in the paperNot a substantial claim
    • The authors state this as an assumption: The bulk material behaves elastically in the numerical models.
  • May combine two claims.

    Findingown data

    In the pure mode-I opening test, the effective damage parameter increases during initial loading and remains constant during unloading.

    “Figure 3c shows that the effective damage parameter increases during the initial loading phase (up until point A) and remains constant during unloading (between points A and B).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    At 110°C, the numerical model closely fits the experimental data, capturing the fast healing kinetics that occurs at elevated temperatures, where material flow and inter-diffusion across crack surfaces are significantly enhanced.

    “At 110 • C (Figure 10h), the numerical model closely fits the experimental data, capturing the fast healing kinetics that occurs at elevated temperatures, where material flow and inter-diffusion across crack surfaces are significantly enhanced.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: The bulk material behaves elastically in the numerical models.
  • May combine two claims. The quote only partly states this claim.

    Findingown data

    In the absence of healing, the numerical solution closely reproduces the analytical reference response from beam theory and linear elastic fracture mechanics, confirming that the cohesive formulation captures the expected mixed-mode fracture behavior.

    “In the absence of healing, the numerical solution closely reproduces the reference response, which confirms that the cohesive formulation captures the expected mixed-mode fracture behavior.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Mi et al., 1998

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    Simulations under pure mode-I and proportional and nonproportional mixed-mode loading confirmed that healing occurs only when crack faces are both in contact and at rest, and that effective damage parameters evolve appropriately under different mechanical histories.

    “Simulations under pure mode-I and proportional and nonproportional mixed-mode loading confirmed that healing occurs only when crack faces are both in contact and at rest, and that effective damage parameters evolve appropriately under different mechanical histories.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: The healing kinetics law activates only during full crack-face contact.
  • May combine two claims.

    Findingreasoning

    Normal damage remains concentrated near the active fracture region, whereas tangential damage extends farther ahead along the still-bonded interface.

    “Normal damage remains concentrated near the active fracture region, whereas tangential damage extends farther ahead along the still-bonded interface.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingnone given

    Ahead of the fracture process zone, the interface remains largely bonded and undergoes predominantly tangential relative displacement under the applied loading, while normal separation remains negligible.

    “Ahead of the fracture process zone, the interface remains largely bonded and undergoes predominantly tangential relative displacement under the applied loading, while normal separation remains negligible.”
    Quote in the paperNot a substantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    In three-point bending tests of notched asphalt mastic beams, the model reproduced the load-displacement curves and healing strength ratios across a wide range of temperatures, effectively capturing the strong temperature dependence of asphalt healing.

    “In three-point bending tests of notched asphalt mastic beams, the model reproduced the load-displacement curves and healing strength ratios across a wide range of temperatures, effectively capturing the strong temperature dependence of asphalt healing.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingreasoning

    Element A, located closer to the initial crack tip, exhibits a larger crack-opening history and a proportionally larger normal contribution, whereas element B, located farther ahead of the advancing crack, exhibits a more balanced mixed-mode state.

    “Element A, located closer to the initial crack tip, exhibits a larger crack-opening history and a proportionally larger normal contribution, whereas element B, located farther ahead of the advancing crack, exhibits a more balanced mixed-mode state.”
    Quote in the paperNot a substantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    In compact tension tests of PMMA specimens, the model reproduced the rapid early recovery and subsequent saturation of fracture toughness over time, demonstrating its applicability to brittle polymers and reinforcing its generality.

    “Finally, in compact tension tests of PMMA specimens, the model reproduced the rapid early recovery and subsequent saturation of fracture toughness over time, demonstrating its applicability to brittle polymers and reinforcing its generality.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the PMMA compact tension simulations, the bulk material is linear elastic with Young's modulus E = 5 GPa and Poisson's ratio ν = 0.3.
  • May combine two claims.

    Findingown data

    Using the calibrated parameters, the model predicts slow, sublinear healing at low temperatures, sigmoidal growth at moderate temperatures, and rapid strength recovery at high temperatures.

    “For instance, using the calibrated parameters, our model predicts slow, sublinear healing at low temperatures (Figure 10f), sigmoidal growth at moderate temperatures (Figure 10g), and rapid strength recovery at high temperatures (Figure 10h).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingreasoning

    As the rest period increases, recovery progressively reduces the extent of the highly degraded region and shifts the damage transition toward the initial crack tip.

    “As the rest period increases, recovery progressively reduces the extent of the highly degraded region and shifts the damage transition toward the initial crack tip.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    The separation between the recovery curves progressively decreases with increasing rest time, indicating that the influence of the healing-rate ratio becomes less pronounced as all cases approach the same asymptotic recovery state.

    “The separation between the recovery curves progressively decreases with increasing rest time, indicating that the influence of the healing-rate ratio becomes less pronounced as all cases approach the same asymptotic recovery state.”
    Quote in the paperNot a substantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingreasoning

    Shear transfer generates small tangential relative displacements ahead of appreciable normal opening, resulting in distributed tangential degradation while the normal cohesive response remains largely intact.

    “Shear transfer generates small tangential relative displacements ahead of appreciable normal opening, resulting in distributed tangential degradation while the normal cohesive response remains largely intact.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingreasoning

    Although both elements A and B reach high effective-damage levels during loading, A begins the rest period farther from the origin and remains in the relatively flat region for a larger portion of the healing trajectory, whereas B begins closer to the steep transition and therefore undergoes a larger reduction in effective damage in both modes over the same rest period.

    “Although both elements reach high effective-damage levels during loading, A begins the rest period farther from the origin and remains in the relatively flat region for a larger portion of the healing trajectory, whereas B begins closer to the steep transition and therefore undergoes a larger reduction in effective damage in both modes over the same rest period.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    For all values of χn/χt, the healing strength ratio increases monotonically with rest time Tr and approaches complete recovery as the rest time increases.

    “For all values of χ n /χ t , the healing strength ratio increases monotonically with T r and approaches complete recovery as the rest time increases.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    Near the actively fractured region, large local deformations produce a highly degraded region, followed by a transition region in which damage decreases rapidly and, farther ahead, a nearly intact region with negligible normal damage and only small tangential degradation.

    “Near the actively fractured region, large local deformations produce a highly degraded region, followed by a transition region in which damage decreases rapidly and, farther ahead, a nearly intact region with negligible normal damage and only small tangential degradation.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    These tests elucidated the roles of the healing parameters in controlling both the rate and shape of various measures of recovery, validating the fidelity of the model to its intended healing kinetics.

    “These tests also elucidated the roles of the healing parameters in controlling both the rate and shape of various measures of recovery, validating the fidelity of the model to its intended healing kinetics.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingreasoning

    In the plateau region, substantial reductions in the history variables produce only modest decreases in damage, whereas relatively small additional reductions near the steeper portion of the surface produce more pronounced recovery.

    “In the plateau region, substantial reductions in the history variables produce only modest decreases in damage, whereas relatively small additional reductions near the steeper portion of the surface produce more pronounced recovery.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    Increasing the rest period Tr progressively restores both the initial reloading stiffness and the first local reloading peak.

    “Increasing T r progressively restores both the initial This preprint research paper has not been peer reviewed.Electronic copy available at: https://ssrn.com/abstract=7528848P r e p r i n t n o t p e e r r e v i e w e d reloading stiffness and the first local reloading peak.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.
  • May combine two claims.

    Findingown data

    The recovery curves for PMMA do not exhibit sigmoidal behavior, unlike most results in previous examples in asphalt mastic.

    “Note that, unlike most of the results in the previous examples in asphalt mastic, these recovery curves do not exhibit sigmoidal behavior-highlighting a distinct material response for PMMA.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    The model reproduces the observed rapid recovery of fracture toughness in the early stages of healing and the eventual plateau.

    “In particular, our model reproduces the observed rapid recovery of fracture toughness in the early stages of healing and the eventual plateau as the”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Spring et al. (2016) interpreted inelastic behavior as a result of material stiffness degradation and adopted a damage mechanics framework, in which damage is characterized by a reduction in the secant stiffness.

    “Spring et al. (2016) interpreted inelastic behavior as a result of material stiffness degradation and adopted a damage mechanics framework, in which damage is characterized by a reduction in the secant stiffness (Lemaitre, 2012).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Lemaitre, 2012

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Interpretationreasoning

    According to the healing evolution law, the healing variable increases during rest periods, causing the maximum effective crack opening κh to decrease.

    “According to Equation ( 22), the healing variable increases during rest periods, causing the maximum effective crack opening, κ h , to decrease.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: During rest periods, the healing variable h evolves according to a reaction-type equation ḣ = χ(1-h)^ξ [1-H(∆)].
  • Classified as probably not a substantial claim. May combine two claims.

    Premisereasoning

    Cohesive zone models explicitly represent cracks as discrete surfaces and have been increasingly adopted to model crack initiation, propagation, and healing in self-healing materials.

    “In contrast, cohesive zone models (CZMs) explicitly represent cracks as discrete surfaces and have been increasingly adopted to model crack initiation, propagation, and healing in self-healing materials.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    The approach provides a unified description of loading, unloading, healing, and reloading, with damage recovery occurring exclusively during rest periods.

    “and provides a unified description of loading, unloading, healing, and reloading, with damage recovery occurring exclusively during rest periods.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    The paper extends the Park-Paulino-Roesler cohesive zone model and introduces a thermodynamically consistent mixed-mode cohesive-healing model with mode-dependent healing kinetics.

    “To address these limitations, we extend the Park-Paulino-Roesler cohesive zone model (CZM) and introduce a thermodynamically consistent mixed-mode cohesive-healing model with mode-dependent healing kinetics.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Park et al., 2009

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Premisecitation

    Spring et al. (2016) demonstrated the thermodynamic consistency of the PPR CZM under pure loading conditions and introduced new unloading-reloading relationships that ensure the PPR model is thermodynamically consistent under arbitrary mixed-mode loading.

    “Spring et al. (2016) demonstrated the thermodynamic consistency of the PPR CZM (Park et al., 2009) under pure loading conditions and introduced new unloading-reloading relationships that ensure the PPR model is thermodynamically consistent under arbitrary mixed-mode loading.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites Spring et al. (2016) source
    • cites Park et al., 2009

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Probably not a substantial claim: may not pass S4 (based). May combine two claims.

    Premisenone given

    Existing cohesive-healing formulations are often restricted to mode-I fracture or do not provide a thermodynamically consistent treatment of healing under general mixed-mode loading.

    “Existing cohesive-healing formulations are often restricted to mode-I fracture or do not provide a thermodynamically consistent treatment of healing under general mixed-mode loading.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Premisenone given

    Continuum models are challenged by their inability to directly capture discrete fracture phenomena, as they represent cracks through regularized (or smeared out) fields rather than as distinct surfaces.

    “Despite their versatility, continuum models are challenged by their inability to directly capture discrete fracture phenomena, as they represent cracks through regularized (or smeared out) fields rather than as distinct surfaces.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Intrinsic self-healing polymers rely on reversible molecular mechanisms-thermally reversible bonds, hydrogen bonding, or chain interdiffusion-to achieve multiple healing cycles without requiring the external delivery of healing agents.

    “Intrinsic self-healing polymers, in particular, rely on reversible molecular mechanisms-thermally reversible bonds, hydrogen bonding, or chain interdiffusion-to achieve multiple healing cycles without requiring the external delivery of healing agents (Wool and O'Connor, 1981;Kim and Wool, 1983;Blaiszik et al., 2010).”
    Quote in the paperNot a substantial claim0 of 3 sources checked
    • cites Wool and O'Connor, 1981 source
    • cites Kim and Wool, 1983 source
    • cites Blaiszik et al., 2010 source
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Interpretationnone given

    Under pure loading conditions, hn = ht = 0 and ḣn = ḣt = 0.

    “As discussed before, under pure loading conditions, h n = h t = 0 and ḣn = ḣt = 0.”
    Quote in the paperNot a substantial claim
    • The authors state this as an assumption: During rest periods, the healing variable h evolves according to a reaction-type equation ḣ = χ(1-h)^ξ [1-H(∆)].
  • Probably not a substantial claim: may not pass S4 (based).

    Premisenone given

    Continuum models are often limited in their ability to simulate mixed-mode fracture and healing, where interaction between multiple loading modes adds further complexity.

    “Moreover, continuum models are often limited in their ability to simulate mixed-mode fracture and healing, where interaction between multiple loading modes adds further complexity.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Because the effective damage parameter d is a monotonically increasing function of κh, d decreases during rest periods, enabling recovery of cohesive properties such as reloading stiffness, cohesive strength, and fracture energy as rest time increases.

    “Because the effective damage parameter, d, is a monotonically increasing function of κ h , it follows that d decreases during rest periods, enabling the recovery of cohesive properties such as reloading stiffness, cohesive strength, and fracture energy as the rest time increases.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: During rest periods, the healing variable h evolves according to a reaction-type equation ḣ = χ(1-h)^ξ [1-H(∆)].
  • May combine two claims.

    Interpretationreasoning

    After healing, the maximum effective crack opening width becomes equal to κh, resulting in effective cohesive traction and effective damage parameter given by Equation (18).

    “After healing, the maximum effective crack opening width becomes equal to κ h , resulting in the effective cohesive traction and corresponding effective damage parameter given by”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: When healing occurs during rest periods, the fiber moves by κκh to regenerate the original broken bond.
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Premisenone given

    Early works consistently identify three key ingredients for intrinsic healing: full contact (wetting) of crack faces, polymer chain diffusion across the interface, and subsequent bond formation or entanglement, which together govern time- and temperature-dependent healing strength.

    “These early works consistently identify three key ingredients for intrinsic healing: full contact (wetting) of crack faces, polymer chain diffusion across the interface, and subsequent bond formation or entanglement, which together govern timeand temperature-dependent healing strength.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Alsheghri and Al-Rub (2015, 2016) formulated a thermodynamically consistent CZM for self-healing materials by introducing internal healing variables into the traction-separation law.

    “For example, Alsheghri andAl-Rub (2015, 2016) formulated a thermodynamically consistent CZM for self-healing materials by introducing internal healing variables into the traction-separation law.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Alsheghri andAl-Rub (2015, 2016)

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Premisecitation

    In Alsheghri and Al-Rub's model, damage and healing evolve concurrently, enabling the simulation of partial strength recovery.

    “In their model, damage and healing evolve concurrently, enabling the simulation of partial strength recovery”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Alsheghri andAl-Rub (2015, 2016)

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Interpretationreasoning

    Under pure loading conditions, κh = κ, which implies h = 0 and ḣ = 0, indicating that healing is inactive during loading.

    “Finally, under pure loading conditions, κ h = κ, which implies h = 0 and ḣ = 0, indicating that healing is inactive during loading.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: During rest periods, the healing variable h evolves according to a reaction-type equation ḣ = χ(1-h)^ξ [1-H(∆)].
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Interpretationreasoning

    The healing viscosity parameters and healing exponents in the healing kinetics model correspond to χn = Ln Hn and χt = Lt Ht, and ξn = ρn + ηn and ξt = ρt + ηt.

    “When comparing Equations ( 48) with the first of Equations ( 28) and ( 29), we can observe that the healing viscosity parameters and healing exponents in our healing kinetics model correspond to χ n = L n H n and χ t = L t H t , and ξ n = ρ n + η n and ξ t = ρ t + η t , respectively.”
    Quote in the paperNot a substantial claim
    • The authors state this as an assumption: The Helmholtz free energy can be split into a mechanical part and a chemical part, where the chemical free energy is related to the extent of the chemical reaction driving the self-healing process.
  • May combine two claims.

    Premisereasoning

    Theoretical models based on polymer chain dynamics provide a mechanistic modeling approach for self-healing materials, but their computational expense makes them expensive to simulate crack propagation and healing in a finite element framework.

    “Theoretical models based on polymer chain dynamics such as those discussed above provide a mechanistic modeling approach to develop constitutive relations for self-healing materials, but the computational expense of solving the reaction-diffusion and the integrals needed to obtain the healing strength ratios make these models computationally expensive to simulate crack propagation and healing in a”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites Wang et al., 2017 source
    • cites Yu et al., 2018

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites Yu et al., 2020

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Interpretationreasoning

    The proposed cohesive-healing model satisfies the Clausius-Duhem inequality, ensuring satisfaction of the second law of thermodynamics.

    “This discussion demonstrates that our proposed cohesive-healing model satisfies the Clausius-Duhem inequality, ensuring satisfaction of the second law of thermodynamics.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: The Helmholtz free energy can be split into a mechanical part and a chemical part, where the chemical free energy is related to the extent of the chemical reaction driving the self-healing process.
  • May combine two claims.

    Interpretationown data

    The mixed-mode cohesive-healing model not only reproduces fracture behavior but also captures the coupled effects of temperature and time on healing kinetics.

    “Overall, the results discussed above confirm that our mixed-mode cohesive-healing model not only reproduces fracture behavior but also captures the coupled effects of temperature and time on healing kinetics.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: The bulk material behaves elastically in the numerical models.
  • May combine two claims.

    Interpretationown data

    The proposed mixed-mode cohesive-healing formulation accurately captures both the fracture and the time-and temperature-dependent healing behavior of asphalt mastic.

    “These findings confirm that our proposed mixed-mode cohesive-healing formulation accurately captures both the fracture and the time-and temperature-dependent healing behavior of asphalt mastic.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: The bulk material behaves elastically in the numerical models.
  • May combine two claims.

    Interpretationown data

    The decrease in healing exponents with increasing temperature promotes faster progression of the healing process, making thermal activation more pronounced.

    “The results in Table 3 also show that the healing exponents (ξ n = ξ t ) generally decrease with increasing temperature, promoting faster progression of the healing process thermal activation becomes more pronounced.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationnone given

    The derivations provided for the finite element implementation are general and applicable to both two-dimensional and three-dimensional cohesive-healing elements.

    “The derivations provided below are general and applicable to both two-dimensional and three-dimensional cohesive-healing elements.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationnone given

    The finite element representation discussed in the paper is general and applies to both two- and three-dimensional elements.

    “The finite element representation discussed above is general and applies to both twoand three-dimensional elements.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationown data

    The calibrated healing parameters reveal distinct trends with healing temperature, highlighting how the model captures the thermally activated nature of healing in asphalt mastic.

    “The calibrated healing parameters in Table 3 reveal distinct trends with healing temperature, highlighting how the model captures the thermally activated nature of healing in asphalt mastic.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: The bulk material behaves elastically in the numerical models.
  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductcitation

    The fracture parameters are adopted from Park and Paulino (2012) and kept fixed throughout the study so that differences among the healing cases arise exclusively from the healing kinetics.

    “We adopt the fracture parameters from Park and Paulino (2012) and keep them fixed throughout the study so that differences among the healing cases arise exclusively from the healing kinetics.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Park and Paulino (2012) source
  • May combine two claims.

    Interpretationreasoning

    The global MMB loading condition produces spatially varying local mode mixity and, consequently, different mixed-mode history states along the interface.

    “The global MMB loading condition therefore produces spatially varying local mode mixity and, consequently, different mixed-mode history states along the interface.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Study design and conductown data

    The model was implemented within a finite element framework and comprehensive verification studies were conducted using single cohesive elements.

    “We implemented the model within a finite element framework and conducted comprehensive verification studies using single cohesive elements.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    Unlike most existing self-healing cohesive models, which are often restricted to mode-I conditions or incorporate healing via ad hoc terms, the approach retains the full mathematical structure of the PPR model while incorporating healing through internal variables that retain memory of maximum crack openings in both the normal and tangential directions, enabling physically meaningful healing under

    “Unlike most existing self-healing cohesive models, which are often restricted to mode-I conditions or incorporate healing via ad hoc terms, our approach retains the full mathematical structure of the PPR model while incorporating healing through internal variables that retain memory of maximum crack openings in both the normal and tangential directions, thus enabling physically meaningful healing”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    Different evolution mechanisms govern loading and healing: during loading, the histories increase according to the local mixed-mode kinematics, whereas during healing they decrease according to the prescribed healing kinetics.

    “During loading, the histories increase according to the local mixed-mode kinematics, whereas during healing they decrease according to the prescribed healing kinetics.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    In the experiments by García (2012), complete fracture was defined to occur when the crack tip reached the load application point.

    “In the experiments byGarcía (2012), complete fracture was defined to occur when the crack tip reached the load application point.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites García (2012)

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Probably not a substantial claim: may not pass S4 (based).

    Interpretationreasoning

    For a mode-I dominant problem, the tangential healing parameters χt and ξt have no effect on the results.

    “Given that this is a mode-I dominant problem, the tangential healing parameters, χt and ξt, have no effect on the results.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationown data

    This difference follows directly from the shear-first local trajectories in Figures 13a,b.

    “This difference follows directly from the shear-first local trajectories in Figures 13a,b.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationown data

    In the present simulations, healing primarily restores the cohesive resistance associated with crack reinitiation, whereas the subsequent propagation response is largely governed by the evolving crack configuration and the fixed cohesive fracture properties.

    “Thus, in the present simulations, healing primarily restores the cohesive resistance associated with crack reinitiation, whereas the subsequent propagation response is largely governed by the evolving crack configuration and the fixed cohesive fracture properties.”
    • Also stated in: § 7 Conclusions · plain
      “The simulations showed that healing primarily restores the cohesive resistance associated with crack reinitiation.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Study design and conductcitation

    Because Jud and Kausch (1979) did not report load-displacement curves nor fracture energy values, and no suitable additional data were found, the fracture parameters for PMMA were estimated based on typical values for PMMA and engineering judgment.

    “Because Jud and Kausch (1979) did not report load-displacement curves nor fracture energy values, and no suitable additional data were found in the literature for similar CT tests, the fracture parameters were estimated based on typical values for PMMA and engineering judgment.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Jud and Kausch (1979) source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Jud and Kausch (1979) tested compact tension specimens made of PMMA with dimensions 26 mm width and height, 3 mm thickness, and an initial notch 0.5 mm wide and 12 mm long.

    “Their CT specimens measured 26 mm in width and height, with a thickness of 3 mm, and contained an initial notch 0.5 mm wide and 12 mm long (see Figure 11a).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Jud and Kausch (1979) source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The finite element implementation follows the approach outlined by Park and Paulino (2012).

    “This implementation follows the approach outlined by Park and Paulino (2012).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Park and Paulino (2012) source
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Study design and conductnone given

    All results presented in this manuscript can be replicated based on the information provided.

    “All results presented in this manuscript can be replicated based on the information provided.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Premisenone given

    Jud and Kausch (1979) only reported fracture toughness values.

    “Jud andKausch (1979) only reported fracture toughness values.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites Jud and Kausch (1979) source
71 of 71
  • The authors state this as an assumption.

    The potential energy can be decomposed into independent normal and shear components.

    “First, following common practice in stress-strain-based constitutive modeling (Simo and Hughes, 2006;Lemaitre and Chaboche, 1994), they assumed that the potential energy can be decomposed into independent normal and shear components.”
  • The authors state this as an assumption.

    When healing occurs during rest periods, the fiber moves by κκh to regenerate the original broken bond.

    “When healing occurs, e.g., during rest periods, we assume that the fiber moves by κκ h to regenerate the original broken bond”
  • The authors state this as an assumption.

    During rest periods, the healing variable h evolves according to a reaction-type equation ḣ = χ(1-h)^ξ [1-H(∆)].

    “During rest periods, we assume that h evolves according to the following reaction-type equation:”
  • The authors state this as an assumption.

    The Helmholtz free energy can be split into a mechanical part and a chemical part, where the chemical free energy is related to the extent of the chemical reaction driving the self-healing process.

    “Different from their work, here we assume that the Helmholtz free energy can be split into a mechanical part, Ψ m , and a chemical part, Ψ c , where the chemical free energy is related to the extent of the chemical reaction driving the self-healing process.”
  • The paper relies on this without support.

    A basic Euler time integration scheme can lead to large integration errors during long rest periods, which reduces the accuracy of healing predictions.

    “A basic Euler time integration scheme can lead to large integration errors during long rest periods, which in turn reduces the accuracy of the healing predictions.”
  • The authors state this as an assumption.

    The bulk material behaves elastically in the numerical models.

    “the bulk material in our numerical models is assumed to behave elastically”
    “we modeled the bulk material as linear elastic”
  • The paper relies on this without support.

    The fracture parameters are independent of healing temperature.

    “These fracture parameters are independent of the healing temperature so we use the same fracture parameters for all the healing temperatures considered here.”
  • The authors state this as an assumption.

    For the PMMA compact tension simulations, the bulk material is linear elastic with Young's modulus E = 5 GPa and Poisson's ratio ν = 0.3.

    “To obtain the numerical results shown in Figures 11c-d, we assumed a linear elastic bulk material with a Young's modulus of E = 5 GPa and a Poisson's ratio of ν = 0.3 (Alsheghri and Al-Rub, 2016).”
  • The authors state this as an assumption.

    For the MMB simulations, the bulk material is linear elastic with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.

    “We model the bulk material as linear elastic, with Young's modulus E = 122 GPa and Poisson's ratio ν = 0.25.”
  • The authors state this as an assumption.

    The healing kinetics law activates only during full crack-face contact.

    “The model considers two internal state variables representing the maximum effective crack openings in the normal and tangential directions, along with a phenomenological healing kinetics law that activates only during full crack-face contact.”
  • The authors state this as an assumption.

    The normal and tangential healing parameters are equal: χn = χt and ξn = ξt.

    “We therefore assumed χn = χt and ξn = ξt in the simulations.”
    “In this work, we assume χ n = χ t and ξ n = ξ t , due to the limited availability of experimental data.”
  • The authors state this as an assumption.

    A representative fracture energy value for PMMA is assumed.

    “We then assumed a representative fracture energy value for PMMA, and estimated the cohesive strength such that the initial fracture response yielded approximately the computed value of the peak load, Pmax.”
  • The paper relies on this without support.

    The fracture parameters calibrated for PBmas samples are applicable to SBSmas samples.

    “Consequently, we used the same fracture parameters calibrated for the PBmas samples to simulate the behavior of the SBSmas samples.”
13 of 13

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Thermodynamic derivation sets healing rates to zero during all reloading

    Major

    The thermodynamic-consistency derivation assumes both healing-variable rates are zero throughout loading, unloading, and reloading. The mode-I verification instead states that the healing variable decreases during reloading after the effective opening is exceeded, so the stated dissipation reduction does not cover that behavior.

1 of 1

Cites

The publisher hasn’t deposited this paper’s reference list.

Research works printed but not linked: 2

  1. Lemaitre, J. (2012). A course on damage mechanics. Springer science & business media.
  2. Simo, J. C. and T. J. Hughes (2006). Computational inelasticity, Volume 7. Springer Science & Business Media.

Authors
Giraldo-Londoño, O., Spring, D. W., Muñetón-López, R. A., & Paulino, G. H.
Affiliations
University of Missouri (US)
Venue
SSRN Electronic Journal
Publisher
Elsevier BV
Published
2026
ISSN
1556-5068 (ISSN-L)
OpenAlex
W7214445656
Cited by
0
References
0
Type
posted content
Open access
Locations
SSRN Electronic Journal (acceptedVersion)
Topics
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer composites and self-healing
  • Physical Sciences › Engineering › Mechanics of Materials › Mechanical Behavior of Composites
  • Physical Sciences › Engineering › Mechanics of Materials › Numerical methods in engineering
Keywords
self-healing materials, mixed-mode fracture, cohesive zone model, thermodynamic consistency, healing kinetics, damage recovery, crack opening displacement, poly(methyl methacrylate), mixed-mode bending, finite element implementation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-09.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-09.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review