Stethoscope acoustics and cervical auscultation of swallowing
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Frequency response characteristics of six popular stethoscopes are reported for the higher frequency range (to 3000 Hz) to supplement equivalent measurements for the lower frequencies (35-1000 Hz) published previously. Spectra of the sounds of swallowing from the throat, transduced with an accelerometer, demonstrate important frequency composition in this higher range. Two stethoscope models were found to have superior transmission characteristics for use in cervical auscultation of swallowing sounds.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The previous setup for both accelerometer and microphone has proven to be effective in collecting swallowing vibrations42–45.”
From Non-invasive identification of swallows via deep learning in high resolution cervical auscultation recordings (2020) · cites this paper as [44]
In the citing paper
“This setup has been shown to be effective at detecting swallowing activity in previous studies [23, 30].”
From A statistical analysis of cervical auscultation signals from adults with unsafe airway protection (2016) · cites this paper as [30]
Citations
Cites
Methodology for detecting swallowing sounds
Takahashi, K., Groher, M., & Michi, K.-I. (1994) · Dysphagia · doi:10.1007/bf00262760 · Cited by 215 · cited 1×
“Research studies on the acoustics of swallowing have generally recorded the sounds using a microphone or accelerometer [5-7, 9-14 ].”
MethodComparison of the acoustic properties of six popular stethoscopes
Abella, M., Formolo, J. M., & Penney, D. G. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.403655 · Cited by 136 · cited 6×
“Figure 4 provides detailed low frequency response data for these models, previously published [18].”
BackgroundInfluentialSelf-citationInterpreting the Sounds of Swallowing: Fluid Flow through the Cricopharyngeus
Hamlet, S. L., Nelson, R. J., & Patterson, R. L. (1990) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348949009900916 · Cited by 84 · cited 1×
“Research studies on the acoustics of swallowing have generally recorded the sounds using a microphone or accelerometer [5-7,9-14].”
BackgroundSelf-citationCervical Auscultation Of Suckle Feeding In Newborn Infants
Vice, F. L., Heinz, J. M., Giuriati, G., Hood, M., & Bosma, J. F. (1990) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1990.tb08479.x · Cited by 66 · cited 3×
“[6] described swallow sounds recorded from infants, portions of which were periodic with a high fundamental frequency.”
BackgroundThe exeter dysphagia assessment technique
Selley, W. G., Flack, F. C., Ellis, R. E., & BROOKS, W. A. (1990) · Dysphagia · doi:10.1007/bf02407270 · Cited by 65 · cited 1×
“Cervical auscultation (listening at the throat with a stethoscope) is being adopted by dysphagia clinicians as a component of clinical evaluation of swallowing [1-9].”
Sounds of swallowing following total laryngectomy
Hamlet, S. L., Patterson, R. L., Fleming, S. M., & Jones, L. (1992) · Dysphagia · doi:10.1007/bf02493450 · Cited by 60 · cited 1×
“Research studies on the acoustics of swallowing have generally recorded the sounds using a microphone or accelerometer [5-7,9-14].”
BackgroundSelf-citationAcoustic Profile of Deglutition
Mackowiak, R. C., Brenman, H. S., & Friedman, M. H. F. (1967) · Experimental Biology and Medicine · doi:10.3181/00379727-125-32300 · Cited by 52
Sonic correlates of human deglutition.
Logan, W. J., Kavanagh, J. F., & Wornall, A. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.2.279 · Cited by 39
Sensorimotor Examination of the Mouth and Pharynx
Bosma, J. F. (2015) · Frontiers of oral physiology/Frontiers of oral biology · doi:10.1159/000393317 · Cited by 32
The Laryngeal Microphone as an Aid to Treatment of Bulbar Poliomyelitis
Stott, F. D. (1953) · BMJ · doi:10.1136/bmj.2.4851.1414 · Cited by 18 · cited 1×
“Cervical auscultation (listening at the throat with a stethoscope) is being adopted by dysphagia clinicians as a component of clinical evaluation of swallowing [1-9].”
Cited by
Non-invasive monitoring of chewing and swallowing for objective quantification of ingestive behavior
Sazonov, E., Schuckers, S., Lopez-Meyer, P., Makeyev, O., Sazonova, N., Melanson, E. L., & Neuman, M. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/5/001 · Cited by 179
“Another important study on the sonic methods of swallow detection has been conducted by Firmin et al (1997) based on the work of Hamlet et al (1994) and Vice et al (1990, 1995).”
MethodDysphagia: Foundation, theory and practice
Cichero, J. A. Y., & Murdoch, B. E. (2006) · Cited by 215
Using cervical auscultation in the clinical dysphagia examination in long-term care
Zenner, P. M., Losinski, D. S., & Mills, R. H. (1995) · Dysphagia · doi:10.1007/bf00261276 · Cited by 170
“The frequency response characteristics of stethoscopes can vary among models but generally provide adequate transmission of sound frequencies up to 1,000 Hz [ 8-10 ].”
BackgroundReliability and Validity of Cervical Auscultation
Borr, C., Hielscher‐Fastabend, M., & Lücking, A. (2007) · Dysphagia · doi:10.1007/s00455-007-9078-3 · Cited by 138
“[12] assumed a close connection between the change of the deglutition sounds and the bolus flow through the upper esophageal sphincter (UES).”
BackgroundReliability and Validity of Cervical Auscultation: A Controlled Comparison Using Video fluoroscopy
Leslie, P., Drinnan, M. J., Finn, P., Ford, G. A., & Wilson, J. A. (2004) · Dysphagia · doi:10.1007/s00455-004-0007-4 · Cited by 157
“We chose to use the radiopaque Littmann Cardio stethoscope as used at bedside to give realistic sounds and optimize recording quality for future acoustic analysis [17].”
MethodAcoustic Signature of the Normal Swallow: Characterization by Age, Gender, and Bolus Volume
Cichero, J. A. Y., & Murdoch, B. E. (2002) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940211100710 · Cited by 113
Acoustic analysis of swallowing sounds: A new technique for assessing dysphagia
Santamato, A., Panza, F., Solfrizzi, V., Russo, A., Frisardi, V., Megna, M., Ranieri, M., & Fiore, P. (2009) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0384 · Cited by 102
Classification of Normal and Dysphagic Swallows by Acoustical Means
Lazareck, L. J., & Moussavi, Z. M. K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836504 · Cited by 88
“IDS and FDS were also documented as the characteristic swishing double-click when the bolus passes through the pharynx into the esophagus [11], [12].”
BackgroundDudik, J. M., Coyle, J. L., & Sejdić, E. (2015) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2015.2408615 · Cited by 97
“noise at either end of the frequency spectrum [13], [28], [38], [39], [43]–[47], [49], [51], [53]–[62], [65], [68]–[73], [84]–[89].”
InfluentialKhalifa, Y., Coyle, J. L., & Sejdić, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-65492-1 · Cited by 82
An Acoustic Profile of Normal Swallowing
Youmans, S. R., & Stierwalt, J. A. G. (2005) · Dysphagia · doi:10.1007/s00455-005-0013-1 · Cited by 79
“Previous studies on cervical auscultation have focused on procedural and instrumental consideration [11,13–13], evaluations involving cervical auscultation and other physiologic measures [7,8,14,15], and acoustic analyses of swallowing sounds [9,10,16,17].”
BackgroundThe Physiologic Cause of Swallowing Sounds: Answers from Heart Sounds and Vocal Tract Acoustics
Cichero, J. A. Y., & Murdoch, B. E. (1998) · Dysphagia · doi:10.1007/pl00009548 · Cited by 77
Cervical Auscultation Synchronized with Images from Endoscopy Swallow Evaluations
Leslie, P., Drinnan, M. J., Zammit-Maempel, I., Coyle, J. L., Ford, G. A., & Wilson, J. A. (2007) · Dysphagia · doi:10.1007/s00455-007-9084-5 · Cited by 85
“A Littmann Cardio III stethoscope (3M, Loughborough, UK) is the most suitable instrument for the frequency range involved in swallowing [ 17 ].”
BackgroundA comparative analysis of swallowing accelerometry and sounds during saliva swallows
Dudik, J. M., Jestrović, I., Luan, B., Coyle, J. L., & Sejdić, E. (2015) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-14-3 · Cited by 72
“This set-up has been proven to be effective at detecting swallowing activity in previous studies by maximizing the signal-to-background-noise ratio [11,28].”
BackgroundMethodResultInfluentialSmartphone-Based Real-time Assessment of Swallowing Ability From the Swallowing Sound
Jayatilake, D., Ueno, T., Teramoto, Y., Nakai, K., Hidaka, K., Ayuzawa, S., Eguchi, K., Matsumura, A., & Suzuki, K. (2015) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2015.2500562 · Cited by 73
Stroud, A., Lawrie, B. W., & Wiles, C. M. (2002) · Clinical Rehabilitation · doi:10.1191/0269215502cr533oa · Cited by 65
Dysphagia and its effects on swallowing sounds and vibrations in adults
Dudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0501-9 · Cited by 58
“This set-up has been proven to be effective at detecting swallowing activity in previous studies by maximizing the signal-to-background-noise ratio [19, 20].”
Neck sensor-supported hyoid bone movement tracking during swallowing
Mao, S., Zhang, Z., Khalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E. (2019) · Royal Society Open Science · doi:10.1098/rsos.181982 · Cited by 47
“This setup has been shown to be effective at detecting swallowing activity in previous studies[23, 24].”
A statistical analysis of cervical auscultation signals from adults with unsafe airway protection
Dudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0110-9 · Cited by 42
“This setup has been shown to be effective at detecting swallowing activity in previous studies [23, 30].”
Deep learning for classification of normal swallows in adults
Dudik, J. M., Coyle, J. L., El-Jaroudi, A., Mao, Z.-H., Sun, M., & Sejdić, E. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.12.059 · Cited by 42
“Past studies have shown that there is an insignificant amount of energy above this frequency range, so only a negligible amount of information should be lost through attenuating the spectrum [33].”
Frakking, T. T., Chang, A. B., O’Grady, K.-A. F., David, M., Walker‐Smith, K., & Weir, K. A. (2016) · Dysphagia · doi:10.1007/s00455-016-9727-5 · Cited by 45
“include differences in (1) auscultation site and clinical population; (2) use of auscultation methods (a stethoscope likely limits the assessor’s ability to detect higher frequencies that are typically associated with swallowing sounds) [45]; and (3) assessors (Shaw et al’s study used speech pathologists and physiothe…”
Detection of swallows with silent aspiration using swallowing and breath sound analysis
Shirazi, S. S., Buchel, C., Daun, R., Lenton, L., & Moussavi, Z. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0958-9 · Cited by 44
Exploration of Pharyngeal Swallowing by Audiosignal Recording
Boiron, M., Rouleau, P., & Metman, E. H. (1997) · Dysphagia · doi:10.1007/pl00009524 · Cited by 38
Automated classification of swallowing and breadth sounds
Aboofazeli, M., & Moussavi, Z. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404069 · Cited by 37
“As in any observational method, the quality of information obtained by auscultation depends on the perceptual skills of the examiner [3, 4 ].”
MethodTime-Frequency Analysis and Hermite Projection Method Applied to Swallowing Accelerometry Signals
Orović, I., Stanković, S., Chau, T. T., Steele, C. M., & Sejdić, E. (2010) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2010/323125 · Cited by 29
“It is being adopted by dysphagia clinicians as a component of the clinical evaluation of swallowing [21].”
BackgroundA comparison between swallowing sounds and vibrations in patients with dysphagia
Movahedi, F., Kurosu, A., Coyle, J. L., Perera, S., & Sejdić, E. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.03.009 · Cited by 33
“A stethoscope is originally used in CA to listen to the acoustic sounds as by-products of the swallowing process [1, 11, 18].”
MethodGroher, M. E. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-18701-5.00007-5 · Cited by 27
NON-INVASIVE MONITORING OF REFLEXIVE SWALLOWING
Firmin, H., Reilly, S., & Fourcin, A. J. (1997) · Cited by 27
Feature selection for swallowing sounds classification
Yadollahi, A., & Moussavi, Z. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353003 · Cited by 25
“In some swallows another click is present at the end of the process and is known as final discrete sound (FDS) [5, 6].”
BackgroundDeep Learning-Based Swallowing Monitor for Realtime Detection of Swallow Duration
Kuramoto, N., Ichimura, K., Jayatilake, D., Shimokakimoto, T., Hidaka, K., & Suzuki, K. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176721 · Cited by 24
“On the other hand, since clinicians need to judge the swallowing functions only with sounds they hear, it is possible that the assessment can be varied by their skill levels or sensitiveness to the sound; therefore, more quantitative and scientific basis is required to improve the method [2][3].”
BackgroundReliability for detecting oropharyngeal aspiration in children using cervical auscultation
Frakking, T. T., Chang, A. B., O’Grady, K.-A. F., David, M., & Weir, K. A. (2016) · International Journal of Speech-Language Pathology · doi:10.1080/17549507.2016.1222452 · Cited by 24
“Stethoscopes are designed to detect respiratory and heart sounds that have reported frequencies between 35 and 1000 Hz, rather than swallowing sounds which have recorded frequencies of up to 8000 Hz (Cichero & Murdoch, 2002; Hamlet et al., 1994).”
BackgroundAnalysis and Classification of Swallowing Sounds Using Reconstructed Phase Space Features
Aboofazeli, M., & Moussavi, Z. (2006) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2005.1416330 · Cited by 21
“As in any observational method, the quality of information obtained by auscultation depends on the perceptual skills of the examiner [4].”
BackgroundMethodVice, F. L., Bamford, O. S., Heinz, J. M., & Bosma, J. F. (1995) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1995.tb11986.x · Cited by 22
Aspirating and Nonaspirating Swallow Sounds in Children: A Pilot Study
Frakking, T. T., Chang, A. B., O’Grady, K.-A. F., David, M., & Weir, K. A. (2016) · Annals of Otology Rhinology & Laryngology · doi:10.1177/0003489416669953 · Cited by 22
“rather than swallowing sounds (which have recorded frequencies of up to 8000 Hz).(24,40) Despite our novel findings, our study has several limitations.”
BackgroundCharacteristics of Dry Chin-Tuck Swallowing Vibrations and Sounds
Dudik, J. M., Jestrović, I., Luan, B., Coyle, J. L., & Sejdić, E. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2431999 · Cited by 23
“However, our peak and center frequencies are still significantly lower than what was reported in past studies on swallowing activity [10], [25], [26].”
ResultComparison of recurrence plot features of swallowing and breath sounds
Aboofazeli, M., & Moussavi, Z. (2006) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2006.09.026 · Cited by 20
“However, the information obtained by this method depends on the skills of the examiner [3].”
MethodHanna, F., Molfenter, S. M., Polacco, R. C., Chau, T. T., & Steele, C. M. (2009) · Dysphagia · doi:10.1007/s00455-009-9229-9 · Cited by 22
“Previous research has explored methodologic aspects of auscultation [2], including the benefits of using different stethoscopes [3] and the best locations on the neck for collecting swallowing sounds, based on the harmonic-to-noise ratio [4, 5].”
MethodA matched dual-tree wavelet denoising for tri-axial swallowing vibrations
Dudik, J. M., Coyle, J. L., El-Jaroudi, A., Sun, M., & Sejdić, E. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.01.012 · Cited by 18
“This setup has been proven to be effective at detecting swallowing activity in previous studies [23,24].”
Acoustical Modeling of Swallowing Mechanism
Shirazi, S. S., & Moussavi, Z. M. K. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2080677 · Cited by 16
Doppler sonar analysis of swallowing sounds in normal pediatric individuals
Cagliari, C. F., Jurkiewicz, A. L., Santos, R. S., & Marques, J. M. (2009) · Brazilian Journal of Otorhinolaryngology · doi:10.1590/s1808-86942009000500016 · Cited by 19
Analysis of Temporal Pattern of Swallowing Mechanism
Aboofazeli, M., & Moussavi, Z. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259354 · Cited by 15
“However, Information obtained by this method depends on the skills of the examiner [3].”
MethodAnalysis of swallowing sounds using hidden Markov models
Aboofazeli, M., & Moussavi, Z. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0285-8 · Cited by 16
“information obtained by this method depends on the skills of the examiner [5].”
MethodAssessment of Swallowing Sounds' Stages with Hidden Markov Model
Moussavi, Z. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616114 · Cited by 14
“Another characteristic sound of swallowing is a click at the end (called the final discrete click) sound [6,7].”
BackgroundDevelopment of Swallowing-Movement-Sensing Device and Swallowing-State-Estimation System
Kurihara, Y., Kaburagi, T., Kumagai, S., & Matsumoto, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2894744 · Cited by 14
Hsu, C., Chen, W., & Chiu, H. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2012.10.002 · Cited by 15
Pilot Study: Magnetic Motion Analysis for Swallowing Detection Using MEMS Cantilever Actuators
Hoffmann, J., Roldán-Vasco, S., Krüger, K., Niekiel, F., Hansen, C., Maetzler, W., Orozco‐Arroyave, J. R., & Schmidt, G. U. (2023) · Sensors · doi:10.3390/s23073594 · Cited by 12
“Such an acoustical dimension of swallowing has also been explored with digital stethoscopes, but the low-pass effect of the diaphragm limits the spectral analysis to frequencies below 1 kHz [15].”
BackgroundBoiron, M., Rouleau, P., Atipo, B., Picon, L., & Metman, E. H. (1999) · Digestive Diseases and Sciences · doi:10.1023/a:1026649205827 · Cited by 12
“Acoustic technique s are currently being developed to study pharynge al swallowing in adults (1, 2) and in childre n (3), and we have already applie d acoustic methods to the description of swallowing behaviors and time of transit of a bolus through the uppe r esophage al sphincte r in relation to consistency (4).”
MethodUpdate on Current Assessment Practices for Dysphagia
Swigert, N. B. (2007) · Topics in Geriatric Rehabilitation · doi:10.1097/01.tgr.0000284763.07678.5a · Cited by 14
Characteristics of the swallowing sounds recorded in the ear, nose and on trachea
Shirazi, S. S., Baril, J.-F., & Moussavi, Z. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0938-0 · Cited by 11
Frakking, T. T., Chang, A. B., David, M., Orbell‐Smith, J., & Weir, K. A. (2019) · Clinical Otolaryngology · doi:10.1111/coa.13402 · Cited by 11
Contribuição da ausculta cervical para a avaliação clínica das disfagia orofaríngeas
Bolzan, G. D. P., Christmann, M. K., Berwig, L. C., Costa, C. D. C., & Rocha, R. M. (2013) · Revista CEFAC · doi:10.1590/s1516-18462013000200023 · Cited by 23
Clinical evaluation of oropharyngeal dysphagia in Machado-Joseph disease
Corrêa, S. M. A., FELIX, V. N., Gurgel, J. L., Sallum, R. A. A., & Cecconello, I. (2010) · Arquivos de Gastroenterologia · doi:10.1590/s0004-28032010000400003 · Cited by 10
“However, all recordings from dysphagic patients show multiple gulps(6).”
BackgroundNg, M. L., & Ki, A. (2022) · International Journal of Language & Communication Disorders · doi:10.1111/1460-6984.12706 · Cited by 9
A review on intelligent aid diagnosis for dysphagia using swallowing sounds
Li, D., Wu, J., Jin, X., Li, Y., Tong, B., Zeng, W., Liu, P., Wang, W., & Shang, S. (2023) · Interdisciplinary Nursing Research · doi:10.1097/nr9.0000000000000040 · Cited by 8
A model for normal swallowing sounds generation based on wavelet analysis
Yadollahi, A., & Moussavi, Z. (2008) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2008.4564651 · Cited by 6
“Index Terms— Swallowing sounds, modeling, wavelet.”
Inexpensive microphone enables everyday digital recording of deglutition murmurs
Staderini, E. M. (2014) · International Symposium on Medical Information and Communication Technology · doi:10.1109/ismict.2014.6825233 · Cited by 5
“Further clinical validation of the proposed system will be essential before starting clinical daily use for cervical auscultation also considering clinical practice styles [32].”
MethodToward a robust swallowing detection for an implantable active artificial larynx: a survey
Mialland, A., Atallah, I., & Bonvilain, A. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02772-8 · Cited by 6
Liu, J., Yu, S., Xu, Y., Li, J., Liu, B., Liu, S., Ning, H., Xu, D., & Low, S. S. (2022) · Journal of Texture Studies · doi:10.1111/jtxs.12728 · Cited by 4
Groher, M. E. (2020) · Elsevier eBooks · doi:10.1016/b978-0-323-63648-3.00009-3 · Cited by 4
da Silva, G. S., de Figueiredo, A. C. G., Zeigelboim, B. S., de Araújo, C. M., Stechman‐Neto, J., & Santos, R. S. (2021) · Research Society and Development · doi:10.33448/rsd-v10i16.23298 · Cited by 3
Cervical Auscultation Machine Learning for Dysphagia Assessment
Chia, A. A., Lum, S., Boo, M., Tan, R., Balamurali, B. T., & Chen, J. (2024) · International Conference on Signal Processing and Communications (SPCOM) · doi:10.1109/spcom60851.2024.10631635 · Cited by 4
“Hamlet et al [19] reported key spectral elements of swallowing sounds on fluids below 3 kHz, with higher frequencies overlapping with noise.”
BackgroundThe Utility of Cervical Auscultation in the Evaluation of Dysphagia
Mills, R. H. (2004) · Perspectives on Swallowing and Swallowing Disorders (Dysphagia) · doi:10.1044/sasd13.4.14 · Cited by 4
“Following their assessment of six popular stethoscopes, Hamlet, Penney, and Formolo (1994) identified two that they believe are most appropriate for cervical auscultation of the swallow: the Littmann Cardiology II and the HewlettPackard Rappaport-Sprague with medium bell and small diaphragm.”
MethodDysphagie: Sind Schluckgeräusche diagnostisch nutzbar?
Kley, C., & Biniek, R. (2005) · Der Nervenarzt · doi:10.1007/s00115-005-1981-y · Cited by 4
Sánchez-Cardona, Y. (2018) · Revista Mexicana de Ingeniería Biomédica · doi:10.17488/rmib.39.2.6 · Cited by 6
Logemann, J. A. (1998) · KARGER eBooks · doi:10.1159/000061102 · Cited by 3
The Aetiology of Oro-Pharyngeal Dysphagia and its Effects in Stroke
Smithard, D. G. (2014) · Journal of Gastroenterology and Hepatology Research · Cited by 2
Vijayan, S. K., & Yeshoda, K. (2024) · Indian Journal of Otolaryngology and Head & Neck Surgery · doi:10.1007/s12070-024-05035-6 · Cited by 1
“Cervical auscultation has been adapted for the assessment of swallowing problems even before two decades [1 ].”
Huiracocha, L., Sulbarán, R. D. R., & Tutivén, M. S. H. (2015) · Americanae (AECID Library) · Cited by 1
Alvarez, C., & Lai, D. (2014) · Open Archive (Karolinska Institutet)
Santos, R. S., Dacheux, E., & Filho, M. (2006) · Cited by 19
Bolzan, G. D. P., Christmann, M. K., Berwig, L. C., Costa, C. D. C., & Rocha, R. M. (2013) · DOAJ (DOAJ: Directory of Open Access Journals)
Gastroenterology & Hepatology Research
(2017) · Gastroenterology & Hepatology Research · doi:10.24966/ghr-2566
Unified medical instrument prototype hardware : final report
Hille, J., Stevenson, J., & Nesler, C. (2014)
Method on gas-chemical calculation of the gas generation process in underground gas generators
Lavrov, N. V., & Yur'evskaia, N. P. (1957) · Podzemn. Gazif. Uglei
Krishnan, G., Swapna, N., Prakash, T., Chandran, S., Chandrashekariah, B., & Sivaranjani, P. (2024) · Journal of Indian Speech Language & Hearing Association · doi:10.4103/jisha.jisha_45_24
Vijayan, S. K., & Yeshoda, K. (2025) · Neurological Sciences · doi:10.1007/s10072-025-08233-4 · Cited by 1
“Before the turn of the century, cervical auscultation was modified to evaluate swallowing issues by using stetho-scopes [5].”
Transfer Learning for Dysphagia Detection
Chia, A. A., Lum, S., Boo, M., Tan, R. X., Balamurali Nair, B. T., & Chen, J.-M. (2024) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon61640.2024.10903053
Zhu, S. N., Kwok, J., Ng, M. L., & Xiong, M. (2026) · Logopedics Phoniatrics Vocology · doi:10.1080/14015439.2026.2627396
“Yet, typical piezoelectric accelerometers have a very limited frequency response and a bandwidth of only 3 to 2,000 Hz [28,29], often resulting in a loss of swallow information, especially when the average swallow sound frequency are higher than 2,000 Hz [19,23,30].”
Bolus Location Associated With Videofluoroscopic and Respirodeglutometric Events
(2005) · doi:10.1044/1092-4388(2005/003
Metadata
- Authors
- Hamlet, S., Penney, D., & Formolo, J.
- Affiliations
- Wayne State University (US)
- St. John Hospital & Medical Center (US)
- Venue
- Dysphagia
- Published
- 1994
- Volume
- 9
- Issue
- 1
- Pages
- 63-8
- ISSN
- 0179-051X (ISSN-L)
- 1432-0460
- OpenAlex
- W1987082571
- Cited by
- 79
- References
- 12
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2023: 3 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 3 · 2018: 3 · 2017: 2 · 2016: 5 · 2015: 6 · 2014: 4 · 2013: 2 · 2012: 3
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Dysphagia (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5p01ca043838-09)
- National Cancer Institute (CA43838)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
- Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
- Keywords
- cervical auscultation, swallowing sounds
- MeSH terms
- Acceleration, Acoustics, Adult, Aged, Auscultation, Deglutition, Equipment Design, Evaluation Studies as Topic, Female, Humans, Male, Middle Aged, Pharynx, Signal Processing, Computer-Assisted, Sound, Transducers, Video Recording
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.