Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 50 of the 52 references it cites were found in a registry or an index.

A comparative analysis of swallowing accelerometry and sounds during saliva swallows

Open access
Dudik, Joshua M, Jestrović, Iva, Luan, Bo, Coyle, James L, Sejdić, Ervin · 2015 · BioMedical Engineering OnLine

Abstract

BACKGROUND: Accelerometry (the measurement of vibrations) and auscultation (the measurement of sounds) are both non-invasive techniques that have been explored for their potential to detect abnormalities in swallowing. The differences between these techniques and the information they capture about swallowing have not previously been explored in a direct comparison. METHODS: In this study, we investigated the differences between dual-axis swallowing accelerometry and swallowing sounds by recording data from adult participants and calculating a number of time and frequency domain features. During the experiment, 55 participants (ages 18-65) were asked to complete five saliva swallows in a neutral head position. The resulting data was processed using previously designed techniques including wavelet denoising, spline filtering, and fuzzy means segmentation. The pre-processed signals were then used to calculate 9 time, frequency, and time-frequency domain features for each independent signal. Wilcoxon signed-rank and Wilcoxon rank-sum tests were utilized to compare feature values across transducers and patient demographics, respectively. RESULTS: In addition to finding a number of features that varied between male and female participants, our statistical analysis determined that the majority of our chosen features were statistically significantly different across the two sensor methods and that the dependence on within-subject factors varied with the transducer type. However, a regression analysis showed that age accounted for an insignificant amount of variation in our signals. CONCLUSIONS: We conclude that swallowing accelerometry and swallowing sounds provide different information about deglutition despite utilizing similar transduction methods. This contradicts past assumptions in the field and necessitates the development of separate analysis and processing techniques for swallowing sounds and vibrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1475-925x-14-3

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Transducer mounting locations. Location of recording devices during data collection. A: Thyroid cartilage B: Top of the suprasternal notch For reference, the microphone (lower device) is approximately 10x30 mm and the accelerometer (upper device) is aligned with the centre axis of the neck.
Figure 1 Transducer mounting locations. Location of recording devices during data collection. A: Thyroid cartilage B: Top of the suprasternal notch For reference, the microphone (lower device) is approximately 10x30 mm and the accelerometer (upper device) is aligned with the centre axis of the neck.CC BY · PubMed Central
Figure 2 Pre- and post-processing waveforms. A single swallow simultaneously recorded with both a microphone and dual axis accelerometer. The top graph is the signal recorded by the microphone while the middle graph is from the anterior-posterior accelerometer axis and the bottom is from the superior-inferior axis. Part (a) shows the raw device outputs while part (b) shows the same signals after our filtering techniques are applied. One can see obvious differences between sound and vibratory signals as well as different vibration directions.
Figure 2 Pre- and post-processing waveforms. A single swallow simultaneously recorded with both a microphone and dual axis accelerometer. The top graph is the signal recorded by the microphone while the middle graph is from the anterior-posterior accelerometer axis and the bottom is from the superior-inferior axis. Part (a) shows the raw device outputs while part (b) shows the same signals after our filtering techniques are applied. One can see obvious differences between sound and vibratory signals as well as different vibration directions.CC BY · PubMed Central
Figure 3 Pre-processing methodology. Block diagram of the signal conditioning process used with our data.
Figure 3 Pre-processing methodology. Block diagram of the signal conditioning process used with our data.CC BY · PubMed Central
Figure 4 Mean wavelet decomposition. Average and standard deviation of the wavelet energy composition of our signals. The left column in each group corresponds to the microphone signal, the middle corresponds to the superior-inferior accelerometer signal, and the right column corresponds to the anterior-posterior signal. The x-axis lists the approximate frequency range of each of the wavelet decomposition levels.
Figure 4 Mean wavelet decomposition. Average and standard deviation of the wavelet energy composition of our signals. The left column in each group corresponds to the microphone signal, the middle corresponds to the superior-inferior accelerometer signal, and the right column corresponds to the anterior-posterior signal. The x-axis lists the approximate frequency range of each of the wavelet decomposition levels.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Research works printed but not linked: 2

  1. Analog Devices: ADXL322: Small and Thin 2g Accelerometer Data Sheet. Norwood, MA: Analog Devices; 2005.
  2. AKG Acoustics: MicroMic, The Original: C411. Wien, AT: AKG Acoustics; 1991.

Cited by

See all 79

Metadata

Authors
Dudik, J. M., Jestrović, I., Luan, B., Coyle, J. L., & Sejdić, E.
Affiliations
University of Pittsburgh (US)
Corresponding author
Sejdić, Ervin
Venue
BioMedical Engineering OnLine
Published
2015-01-12
Volume
14
Issue
1
Pages
3-3
ISSN
1475-925X (ISSN-L)
OpenAlex
W2143014063
Cited by
72
References
52
Citations by year
2026: 1 · 2025: 9 · 2024: 6 · 2023: 5 · 2022: 4 · 2021: 10 · 2020: 8 · 2019: 2 · 2018: 11 · 2017: 6 · 2016: 7 · 2015: 3
FWCI
19.74
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • BioMedical Engineering OnLine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • D-Scholarship@Pitt (University of Pittsburgh) (acceptedVersion)
Funders
  • University of Pittsburgh (UL1TR000005, UL1RR024153, RR024153)
  • National Institutes of Health (UL1TR000005, RR024153, TR000005)
  • National Center for Research Resources (UL1RR024153)
  • National Center for Advancing Translational Sciences
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD074819)
Topics
  • Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
  • Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
Keywords
swallowing, accelerometry, swallowing sounds, auscultation, time-frequency features, sex differences, wavelet denoising
MeSH terms
Adolescent, Adult, Aged, Aging, Algorithms, Deglutition, Female, Humans, Male, Middle Aged, Saliva, Sex Characteristics, Signal Processing, Computer-Assisted, Sound, Transducers, Young Adult, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparative analysis of swallowing accelerometry and sounds during saliva swallows. https://app.cochat.ai/papers/10.1186/1475-925x-14-3
The paper
Dudik, J. M., Jestrović, I., Luan, B., Coyle, J. L., & Sejdić, E. (2015). A comparative analysis of swallowing accelerometry and sounds during saliva swallows. BioMedical Engineering OnLine. https://doi.org/10.1186/1475-925x-14-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.