Abstract

A simple method for measuring the tendon reflexes was developed. A manually operated, electronic reflex hammer was applied that enabled measurement of the strength of tendon taps. Reflex responses were recorded by surface electromyography. Stimulus-response relations and latencies of tendon reflexes in the biceps, triceps, quadriceps and triceps surae were examined in 40 healthy subjects. A characteristic relation between stimulus strength and response amplitude was found which could be described by an empirical function. Latencies of both arm and leg reflexes were linearly related to the height of the subjects. Variations of reflex amplitudes within and between subjects were comparable with previous results obtained with more complicated techniques. Although repeatability of measurement of the amplitude is limited by the variability of reflexes, significant agreement was found between repeated measurements. Most reflex amplitudes were diminished during repeated examination after a short interval. Both measurement and clinical examination showed the frequent occurrence of left-right asymmetry of reflex amplitudes. These left-right differences were reproducible to a significant degree on repeated measurements after more than 2 years.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf00314505

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 25 references

Research works printed but not linked: 3

  1. Knowlton GC, Britt LP (1949) Relation of height and age to reflex time. Am J Physiol 159:576
  2. Paillard J (1955) Réflexes at régulations d'origine proprioceptive chez l'homme. Étude neurophysiologique et psychophysiologique. Librairie Arnette, Paris
  3. Wadman WJ, Boerhout W, Denier van der Gon JJ (1980) Responses of the arm movement control system to force impulses. J Hum Movement Stud 6:280?302

Cited by

See all 52

Metadata

Authors
Stam, J., & van Crevel, H.
Affiliations
Amsterdam UMC Location University of Amsterdam (NL)
Venue
Journal of Neurology
Published
1989-05
Volume
236
Issue
4
Pages
231-237
ISSN
  • 0012-1037 (ISSN-L)
  • 0340-5354
  • 1432-1459
OpenAlex
W2016711436
Cited by
51
References
25
Citations by year
2026: 2 · 2025: 1 · 2024: 3 · 2021: 4 · 2020: 2 · 2019: 1 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 5 · 2014: 1 · 2013: 4 · 2012: 4
FWCI
1.20
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Journal of Neurology (publishedVersion)
  • PubMed (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • Pure Amsterdam UMC (submittedVersion)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
deep tendon reflexes, surface electromyography, stimulus-response relationship, reflex latency, biceps brachii, triceps brachii, quadriceps, triceps surae, left-right asymmetry, repeatability, healthy volunteers
MeSH terms
Adult, Electromyography, Female, Humans, Male, Reaction Time, Reference Values, Reflex, Stretch

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.