CoChat

The validity of some haematological and elisa methods for the diagnosis of canine heartworm disease

Martini, M., Capelli, G., Poglayen, G., Bertotti, F., Turilli, C. · 1996 · Veterinary Research Communications

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Examinations for heartworm (Dirofilaria immitis) were performed on 175 impounded dogs from a hyperendemic area of the Po Valley (Italy). Each blood sample was used with five haematological diagnostic methods (filtration, direct smear, modified Knott, clotted blood and capillary tube) and three commercial ELISA kits (PetChek, Diasystems, Uni-Tec). The results were compared with the true infection status obtained from post-mortem examination of the heart, pulmonary arteries, thoracic venae cavae and lungs. The prevalence of the infection by adult worms at necropsy was 63%. The sensitivity of the tests ranged from 60% (capillary tube) to 81% (Diasystems) and the specificity from 88% (filtration) to 98% (PetChek). The results of all the tests differed significantly (p < 0.01) from those obtained at necropsy. The sensitivity of the tests was also assessed with respect to the differing numbers of worms in the hosts. A positive correlation between the worm burden and the sensitivity was observed in all the tests. It is apparent that the ELISA methods were better able to detect cases with a low number of worms than the haematological tests.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf00366539

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Otto, G.F., 1978. The significance of microfilaraemia in the diagnosis of heartworm infection. In: H.C.Morgan, G.F.Otto, R.F.Jackson and C.H.Courtney (eds), Proceedings of the Heartworm Symposium, 1977, Atlanta, Georgia, (Veterinary Medicine Publishing Inc., Bonner Springs, Kansas), 22?30

Cited by

See all 24

Metadata

Authors
Martini, M., Capelli, G., Poglayen, G., Bertotti, F., & Turilli, C.
Affiliations
  • University of Bologna (IT)
  • University of Padua (IT)
  • Istituto Zooprofilattico Sperimentale delle Venezie (IT)
Venue
Veterinary Research Communications
Published
1996
Volume
20
Issue
4
Pages
331-339
ISSN
  • 0165-7380 (ISSN-L)
  • 1573-7446
OpenAlex
W2071444404
Cited by
24
References
10
Citations by year
2025: 2 · 2023: 3 · 2021: 1 · 2020: 2 · 2018: 1 · 2016: 1 · 2014: 2 · 2013: 2 · 2012: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Veterinary Research Communications (publishedVersion)
  • PubMed (publishedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Parasitic Diseases Research and Treatment
  • Life Sciences › Immunology and Microbiology › Parasitology › Helminth infection and control
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Research on Leishmaniasis Studies
Keywords
canine heartworm disease, Dirofilaria immitis, ELISA, sensitivity and specificity, worm burden, necropsy confirmation, Po Valley
MeSH terms
Animals, Dirofilaria, Dirofilariasis, Dog Diseases, Dogs, Enzyme-Linked Immunosorbent Assay, Female, Heart, Hematologic Tests, Italy, Lung, Male, Sensitivity and Specificity, Reproducibility of Results, Prevalence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.