CoChat

Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method

Andrade, C., Alonso, C. · 2004 · Materials and Structures
Cited by 560

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/bf02483292

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 61

  1. Andrade, C. and González, J. A., ‘Quantitative measurements of corrosion rate of reinforcing steels embedded in concrete using polarization resistance measurements’,Werkstoffe und Korrosion 29, (1978), 515–519. · doi:10.1002/maco.19780290804
  2. Stern, M. and Geary, A. L., ‘Electrochemical Polarization: I. A. theoretical analysis of the shape of polarization curves’,Journal of Electrochemical Soc. 104 (1) (1957) 56–63. · DOI · Paper page
  3. Stern, M. and Weisert, E.D., ‘Experimental observations on the relations between polarization resistance and corrosion rate’, Proc. American Society Testing, Materials59 (1958) 1280.
  4. Feliú, S., González, J.A., Andrade and C. Feliú, V., ‘On-site determination of the Polarization Resistance in a reinforced concrete beam’,Corrosion (USA)43 (Sept, 1987) 1–9.
  5. Andrade, C., ‘New electrochemical technique for the corrosion measurement in reinforced and presstressed concretes. Use of inhibitor admixtures as prevention method’, Ph.D. Thesis-Faculty of Chemistry, Complutense Univ. of Madrid, July 1973.
  6. Lorenz, W.J. and Mansfeld, F., ‘Determination of corrosion rates by electrochemical DC and AC methods’,Corrosion Science,21(9) (1981) 647–672. · DOI · Paper page
  7. Epelboin, I., Gabrielli, C., Keddam, M. and Takenouti, H., ‘Alternating-current impedance measurements applied to corrosion studies and corrision-rate determination’, Electrochemical Corrosion Testing, ASTM STP 727. F. Mansfeld and U. Bertocci, Eds., American Society for Testing and Materials (1981) 150–166. · doi:10.1520/stp28031s
  8. Gabrielli, C., Keddam, M., Takenouti, H., Vu Quang Kinh and Bourelier, F., ‘The relationship between the impedance of corroding electrode and its polarization resistance determined by a linear voltage sweep technique’,Electrochimica Acta 24 (1979) 61–65. · doi:10.1016/0013-4686(79)80042-0
  9. McDonald, D.D. and McKubre, M.C.H., ‘Electrochemical Impedance Techniques in corrosion science’, Electrochemical Corrosion Testing ASTM STP 727-F. Mansfeld and U. Bertocci Eds. (1981) 110–149. · doi:10.1520/stp28030s
  10. González, J.A. and Andrade, C., ‘Effect of carbonation, chlorides an relative ambient humidity on the corrosion of galvanized rebars embeded in concrete’,British Corrosion Journal,17(1) (1982) 21–28. · DOI
  11. Gouda, V.K., Shater, M.A. and Mikhail, R. Sh., ‘Hardened portland blast-furnace slag cement pastes, II. The corrosion behaviour of steel reinforcement’,Cement and Concrete Research 5 (1975) 1–13. · doi:10.1016/0008-8846(75)90103-9
  12. Glass, G.K., Page, C.L. and Short, N.R., ‘Factors affecting the corrosion rate steel in carbonated mortars’,Corrosion Science,32(12) (1991) 1283–1294. · DOI
  13. Hardon, R.G. Lambert, P. and Page, C.L., ‘Relationship between electrochemical noise and corrosion rate of steel in salt contaminated concrete’,British Corrosion Journal,23 (4) (1988) 225–228. · doi:10.1179/000705988798270721
  14. Lambert, P., Page, C.L. and Vassie, P.R.W., ‘Investigations of reinforcement corrosion. 2. Electrochemical monitoring of steel in chloride-contaminated concrete’,Materials and Structures/Matériaux et Constructions 24 (1991) 351–358. · DOI · Paper page
  15. Pollet, V. and Raharinaivo, A., ‘Assessment of damage by corrosion: Techniques for predicting the extension of rebar corrosion’, International Symposium on Bridge Engineering and Management in Asian countries, PIARC, Jakarta (Indonesia) 10–13, September (1996).
  16. Raharinaivo, A.L. and Carpio, J.J., ‘The steeping down the current method: a new corrosion control for cathodic protection of steel’, NACE Conference Corrosion '92, Nashville, Paper 228, (1992) 9.
  17. Dhouibi-Hachani, L, Raharinaivo, A., Triki, E. and Fiaud, C., ‘Assessing the corrosion of rebars in concrete deteriorated by sulfates and carbonation’, Int. Conference on Corrosion and Corrosion Protection of steel in Concrete. Ed. R.N. Swamy, Sheffield, July (1994) 258–267.
  18. Berke, N.S., Shen, D.F. and Sundberg, K.M., ‘Comparison of the polarization resistance technique to the macrocell corrosion technique’, Corrosion Rates of steel in Concrete, ASTM-1065, N. Berke, V. Chacker and D. Whiting Eds. (1990)38–51. · doi:10.1520/stp25014s
  19. Hope, B.B. and Ip, A.K.C. ‘Corrosion of steel in concrete made with slag cement’,ACI Materials Journal (Nov.–Dec. 1987) 525–531.
  20. Hansson, C.M., ‘Comments on electrochemical measurements of the rate of corrosion of steel in concrete’,Cement & Concrete Res.,14 (1984) 574–584. · doi:10.1016/0008-8846(84)90135-2
  21. Gulikers, J., ‘Numerical simulation of corrosion rate determination by linear polarization’, Rilem PRO 18, Workshop on Measurement and interpretation of on-site corrosion rate (Mesina), C. Andrade, C. Alonso, J. Fullea, J. Polimón and J. Rodriguez Eds., Madrid, Feb. (1999).
  22. Pedeferri, P., ‘Corrosion and Protection of Metallic Materials’, Librería Politécnico de Milano, Italy (1978) (only in Italian).
  23. González, J.A., Molina, A., Escudero, M.L. and Andrade, C., ‘Errors in the electrochemical evaluation of very small corrosion rates. Part. I. Polarization resistance method applied to corrosion of steel in concrete’,Corrosion Science (UK)25 (1985) 917–930. · doi:10.1016/0010-938x(85)90021-6
  24. Glass, G.K., Page, C.L., Short, N.R. and Yu, S.W., ‘An investigation of galvanostatic transient methods used to monitor the corrosion rate of steel in concrete’,Corrosion Science 35 (5–8) (1993) 1585–1592. · doi:10.1016/0010-938x(93)90388-w
  25. Newton, C.J. and Sykes, J.M., ‘A galvanostatic pulse technique for investigation of steel corrosion in concrete’,Corrosion Science 28 (1988) 1051–1074. · DOI
  26. Elsener, B., Klinhoffer, O., Frolund, T., Rislund, E., Schiegg, Y. and Böhni, H., ‘Assessment of reinforcement corrosion by means of glavanostatic pulse technique’, Int. Conference on Repair of Concrete Structures, Svolvær, Norway, Edited by A. Blackvoll, May (1997) 391–400.
  27. Feliú, S., González, J.A., Andrade, C. and Feliú, V., ‘The determination of the corrosion rate of steel in concrete by a non-stationary method’,Corrosion Science 26 (1986) 961–970. · doi:10.1016/0010-938x(86)90086-7
  28. Hladky, K., Callow, L.M. and Dawson, J., ‘Corrosion rates from impedance measurements: an introduction’,British Corrosion J.,15 (1) (1980) 20–25 · DOI
  29. Wenger, F., Galland, J., Lemoine, L., ‘Méthode de contrôle de la corrosion des armatures de béton en milieu marin’, International Symposium on Behaviour of offshore concrete structures, Brest, France, October (1980).
  30. Andrade, C. and Castelo, V., ‘Practical measurement of the A.C. Impedance of steel bars embedded on concrete by means of a Spectrum Analyzer, Fast Fourier Transform’,British Corrosion Journal (UK)19 (1984) 93–100. · doi:10.1179/000705984798273425
  31. Andrade, C., Soler L. and Nóvoa, X.R., ‘Advances in electrochemical impedance measurements in reinforced concrete’, 5th Intern. Symposium on electrochemical methods in Corrosion Research, EMCR'94, Sesimbra, Portugal, Sept, 1994.
  32. Epelboin, I., Gabrielli, C., Keddam, M. and Takenouti, H., ‘Alternating-current impedance measurements applied to corrosion studies and corrosion rate determinations’, ASTM STP 727 ‘Electrochemical Corrosion Testing”, F. Mansfeld and U. Bertocci, Eds., American Society for Testing and Materials (1981) 150–166. · doi:10.1520/stp28031s
  33. Hachani, L., Carpio, J., Fiaud, C., Raharinaivo, A. and Triki, E., ‘Steel corrosion in concretes deteriorated by chlorides and sulphates: electrochemical study using impedance spectrometry and stepping down the current method’,Cement and Concrete Research,22 (1992) 55–66. · doi:10.1016/0008-8846(92)90136-j
  34. Feliú, S., Galvan, J.C., Feliú, Jr., S., Bastidas, J.M., Simancas, J., Morcillo, M. and Almeida, E.M., ‘An electrochemical impedance study of the behaviour of some pretreatments applied to rusted steel surfaces’,Corrosion Science,35 (5–8) (1993) 1351–1358. · doi:10.1016/0010-938x(93)90357-m
  35. Mansfeld, F., ‘Recording and analysis of AC impedance data for corrosion studies. I. Background and methods of analysis’,Corrosion (NACE)36 (5), Mayo (1981). · DOI · Paper page
  36. Elsener, B., Hug, A., Bürchler, D. and Böhni, H., ‘Evaluation of localized corosion of steel in concrete by galvanostatic pulse technique’, Conference on “Corrosion of Reinforcement in Concrete Construction”, C.L. Page, P.B. Bamforth and J.L. Figg Eds. SCI, Cambridge (1996) 264–272.
  37. González, J.A., Andrade, C., Alonso, C. and Feliú, S., ‘Comparison of rates of general corrosion and maximum pitting penetratoon on concrete embedded steel reinforcements’,Cement & Concrete Research,25(2) (1995) 257–264. · doi:10.1016/0008-8846(95)00006-2
  38. Andrade, C., Alonso, C. and González, J.A., ‘An initial effort to use corrosion rates measurements for estimating rebar durability’, Corrosion Rates of Steel in Concrete ASTM STP-1065, N. Berke, V. Chacker and D. Whiting Eds. (1990) 29–37. · DOI
  39. Mansfeld, F., ‘The relationship between galvanic current and dissolution rates’,Corrosion (NACE)29(10) (1973) 403–405. · doi:10.5006/0010-9312-29.10.403
  40. Andrade, C., Maribona, I.R., Feliú, S., González, J.A. and Feliú Jr., S., ‘The effect of macrocells between active and passive areas of steel reinforcements’,Corrosion Science 33 (2) (1992) 237–249. · doi:10.1016/0010-938x(92)90148-v
  41. Andrade, C., Merino, P., Nóvoa, X.R., Pérez, M.C., M.C. and Soler, L., ‘Passivation of reinforcing steel in concrete’,Materials Science Forum 192–194 (1995) 891–898. · doi:10.4028/www.scientific.net/msf.192-194.891
  42. Andrade, C., Bolzoni, F., Cabeza, M., Nóvoa, X.R. and Pérez, M.C., ‘Measurement of steel corrosion in concrete by electrochemical techniques: influence of the redox processes in oxide scales’, in ‘Electrochemical Approach to Selected Corrosion and Corrosion Control Studies, European Federation of Corrosion Pub., no. 28, P.L. Bonora and F. Deflorian Eds. The Institute of materials, London, UK, Cap. 25, (2000) 332–343.
  43. Andrade, C., Keddam, M., Nóvoa, X.R., Pérez, M.C., Rangel, M.C. and Takenouti, H., ‘Elecrochemical behaviour of steel rebars in concrete: influence of environmental factors and cement chemistry’,Electrochimica Acta,46(24–25) (2001) 3905–3912. · doi:10.1016/s0013-4686(01)00678-8
  44. Alonso, C., Andrade, C. Izquierdo, M., Nóvoa, X.R. and Pérez, M.C., ‘Effect of protective oxide scales in the macrogalvanic behaviour of concrete reinforcements’,Corrosion Science 40(8) (1998) 1379–1389. · doi:10.1016/s0010-938x(98)00040-7
  45. Feliú, S., González, J.A., Andrade, C. and Feliú, V., ‘Determining polarization resistance in reinforced concrete slabs’,Corrosion Science 29(1) (1989) 105–113. · doi:10.1016/0010-938x(89)90083-8
  46. Seghal, A., Kho, Y.T., Osseo-Asare, K. and Pickering, H.W., ‘Comparison of corrosion rate-measuring devices for determining corrosion rate of steel in concrete systems’,Corrosion Engineering 48 (1992) 871–880. · doi:10.5006/1.3315888
  47. Andrade, C. and Alonso, C., ‘Corrosion rate monitoring in the laboratory and on-site’,Construction and Building Materials 10(5) (1996) 315–328. · DOI
  48. Elsener, B. and Böhni, H., ‘Galvanostatic pulse measurements. Rapid on-site corrosion monitoring’, Int. Conference on Corrosion and Corrosion Protection of steel in Concrete, Sheffield, UK, Ed. R.N. Swamy, July (1994) 236–246.
  49. Mietz, J. and Isecke, B., ‘Electrochemical potential monitoring on reinforced concrete structures using anodic pulse techniques’, Conference on ‘Non-destructive Testing in Civil Engineering’, H. Bungey Ed., The British Institute of NDT,2 (1993) 567.
  50. Feliú, S., González, J.A. and Andrade, C., ‘Multiple-electrode method for estimating the polarization resistance in large structures’,Journal of Applied Electrochemistry,26 (1996) 305–309. · doi:10.1007/bf00242100
  51. Andrade, C., Sarria, J. and Alonso, C., ‘Statistical study on simultaneous monitoring of rebar corrosion rate and internal relative humidity in concrete structures exposed to the atmosphere’, Conference on Corrosion of Reinforcement in Concrete Constructio, C.L. Page, P.B., Bamforth and J.L. Figg Eds. SCI, Cambridge (1996) 233–242.
  52. Andrade, C. and alonso, C., ‘Values of corrosion rate of steel in concrete in order to predict service life of concrete structures,’, ASTM STP-1194 ‘Application of accelerated corrosion tests to service life prediction of materials’, G. Cragnolino and U. Sridhan Eds. (1994) 282–295. · DOI
  53. Andrade, C., Sarria, J. and Alonso, C., ‘Relation between climate and corrosion rate’, Workshop on Measurement and Interpretation of on-site corrosion rates, MESINA, RILEM PRO 18, C. Andrade, C. Alonso, J. Fullea, J. Polimon and J. Rodríguez, Eds., RILEM Publ., Madrid (Feb. 1999) 123–141.
  54. Andrade, C., Sarria, J. and Alonso, C., ‘Relative humidity in the interior of concrete exposed to natural and artificial weathering’,Cement and Concrete Research 29 (1999) 1249–1259. · DOI
  55. Andrade, C. and Alonso, C., ‘On-site measurements of corrosion rate of reinforcements’,Construction and Building Materials 15 (2001) 141–145. · doi:10.1016/s0950-0618(00)00063-5
  56. Andrade, C., Fullea, J. and Alonso, C., ‘The use of the graph corrosion rate-sensitivity in the measurement of the corrosion current’, Workshop on Measurement and Interpretation of On-Site Corrosion Rates, MESINA, RILEM PRO, 18, C. Andrade, C. Alonso, J. Fullea, J. Polimon and J. Rodríguez, Eds. RILEM Pub., Madrid (Feb. 1999) 157–165.
  57. Andrade, C., Alonso, C. González, J.A. and Rodríguez, J., ‘Remaining service life of corroded structures’, Proceedings of IABSE Symposium on Durability of Structures, Lisbon, September 1989, 359–363.
  58. Rodríguez, J., Ortega, L.M. and Casal, J.: Corrosion of reinforcing bars and service life of reinforced concrete structures: corrosion and bond deterioration’, Internation Conference on Concrete Across Borders, Odense (Denmark) Vol. 1 (1994) 215–226.
  59. Rodríguez, J., Ortega, L.M., Aragoncillo, J., Izquierdo, D. and Andrade, C., ‘Structural assessment for residual life calculation of concrete structures affected by reinforcement corrosion’, Int. RILEM Workshop on Life Prediction and aging management of concrete structures, D. Naus Ed., Rilem Publ., Cannes, France (October 2000) 97–111.
  60. Rodríguez, J., Ortega, L.M., Casal, J. and Díez, J.M. ‘Corrosion of reinforcement and service life of concrete structures’, in ‘Durability of Building Materials and components’, Vol. I, C. Sjöström Ed., E&FN Sponn Publ., London (1996) 117–126.
  61. Rodríguez, J., Ortega, L.M., Casal, J. and Díez, J.M., ‘Assessing structural conditions of concrete structures with corroded reinforcements’, Conference on Concrete Repair, Rehabilitation and Protection, Dundee, U.K., R.K. Dhir and M.R. Jones Eds., E&FN Spon Publ., London (June 1996) 65–77.

Cited by

See all 560

Metadata

Authors
Andrade, C., & Alonso, C.
Venue
Materials and Structures
Published
2004-11
Volume
37
Issue
9
Pages
623-643
ISSN
  • 1359-5997
  • 1871-6873
Cited by
560
References
1
Language
en
Licence
www.springer.com/tdm (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method. https://app.cochat.ai/papers/10.1007/bf02483292
The paper
Andrade, C., & Alonso, C. (2004). Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method. Materials and Structures. https://doi.org/10.1007/bf02483292

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.