The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Sensitive fluorometric method for tissue tocopherol analysis
Abstract
A sensitive, highly reproducible method for tissue tocopherol analysis that combines saponification in the presence of large amounts of ascorbic acid to remove interfering substances, extraction of the nonsaponifiable lipids with hexane, and fluorometric measurement of the tocopherol is presented. The nonsaponifiable lipid phase contained only one fluorochrome in the 290 nm excitation and 330 nm emission range, and it was identified as tocopherol by thin layer and column chromatography. Column chromatography of the hexane extract of a saponified,14 C‐tocopherolspiked microsomal fraction showed that no measurable oxidation to tocopherylquinone has occurred. The fluorometric method for tocopherol analysis was applied to homogenates and subcellular fractions from rat liver, kidney, lung, and heart and red blood cells. The heavy mitochondrial and microsomal fractions had the highest subcellular concentrations of tocopherol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue fractionation studies. 6. Intracellular distribution patterns of enzymes in rat-liver tissue
de Duve, C., Pressman, B. C., Gianetto, R., Wattiaux, R., & Appelmans, F. (1955) · Biochemical Journal · doi:10.1042/bj0600604 · Cited by 4,174
Protein Determination of Large Numbers of Samples
Miller, G. L. (1959) · Analytical Chemistry · doi:10.1021/ac60149a611 · Cited by 1,585
Thin-layer chromatography, a laboratory handbook
(1965) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)97444-8 · Cited by 819
Lipid chromatographic analysis
James, A. T. (1968) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)99159-9 · Cited by 538
Studies on the electron transport system
Crane, F. L., Widmer, C., Lester, R. L., Hatefi, Y., & Fechner, W. (1959) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(59)90024-1 · Cited by 220
Simultaneous fluorometric determinations of vitamins A and E in human serum and plasma
Thompson, J. N., Erdödy, P., & Maxwell, W. B. (1973) · Biochemical Medicine · doi:10.1016/0006-2944(73)90045-8 · Cited by 108
The metabolism of C14‐α‐tocopheryl quinone and C14‐α‐tocopheryl hydroquinone
Chow, C. K., Draper, H. H., Csallany, A. S., & Chiu, M. (1967) · Lipids · doi:10.1007/bf02531852 · Cited by 26
Cited by
[16] Vitamin E analysis methods for animal tissues
Desai, I. D. (1984) · Methods in Enzymology · doi:10.1016/s0076-6879(84)05019-9 · Cited by 850
Cytochrome P450 ω-Hydroxylase Pathway of Tocopherol Catabolism
Sontag, T. J., & Parker, R. S. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m201466200 · Cited by 458
Lipid Peroxidation and Mechanisms of Toxicity
Horton, A. A., Fairhurst, S., & Bus, J. S. (1987) · CRC Critical Reviews in Toxicology · doi:10.3109/10408448709089856 · Cited by 339
Hatam, L. J., & Kayden, H. J. (1979) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)40587-5 · Cited by 334
Tocopherols and tocotrienols in membranes: A critical review
Atkinson, J., Epand, R. F., & Epand, R. M. (2008) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2007.11.010 · Cited by 287
Metadata
- Authors
- Taylor, S. L., Lamden, M. P., & Tappel, A. L.
- Venue
- Lipids
- Publisher
- Wiley
- Published
- 1976-07
- Volume
- 11
- Issue
- 7
- Pages
- 530-538
- ISSN
- 0024-4201 (ISSN-L)
- 1558-9307
- OpenAlex
- W1983021928
- Cited by
- 356
- References
- 7
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitive fluorometric method for tissue tocopherol analysis. https://app.cochat.ai/papers/10.1007/bf02532898
- The paper
- Taylor, S. L., Lamden, M. P., & Tappel, A. L. (1976). Sensitive fluorometric method for tissue tocopherol analysis. Lipids. https://doi.org/10.1007/bf02532898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.