Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record.

Measurement of malondialdehyde by high performance liquid chromatography with fluorescence detection

Tatum, Vickie L., Changchit, Charus, Chow, Ching K.·1990·Lipids

Abstract

A method has been developed to measure malondial‐dehyde (MDA) in biological systems. MDA was reacted with 2‐thiobarbituric acid (TBA) in the presence of butylated hydroxytoluene (BHT) to minimize formation of artifacts. Initial separation of the TBA‐MDA adduct was accomplished by isobutanol extraction. Further elimination and separation of interfering substances was achieved by high performance liquid chromatography. The mobile phase consisted of a 1∶1 (v/v) mixture of methanol and water with 0.05% (w/v) tetrabutyl ammonium dihydrogen phosphate added as an ion pairing reagent. At a flow rate of 1 ml/min, the TBA‐MDA adduct was eluted from a 15‐cm, c‐18, reversed phase column in approximately 4.9 min. The TBA‐MDA adduct was quantitated with a fluorescence detector set at 515 nm excitation and 550 nm emission. Using this method, picomole quantities of MDA can be easily detected in plasma and liver samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/bf02535752

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Tatum, V. L., Changchit, C., & Chow, C. K.
Venue
Lipids
Publisher
Wiley
Published
1990-04
Volume
25
Issue
4
Pages
226-229
ISSN
  • 0024-4201 (ISSN-L)
  • 1558-9307
OpenAlex
W2023632376
Cited by
169
References
0
FWCI
5.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of malondialdehyde by high performance liquid chromatography with fluorescence detection. https://app.cochat.ai/papers/10.1007/bf02535752
The paper
Tatum, V. L., Changchit, C., & Chow, C. K. (1990). Measurement of malondialdehyde by high performance liquid chromatography with fluorescence detection. Lipids. https://doi.org/10.1007/bf02535752

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.