This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA 1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA 1c measurements are applicable to pregnant women with diabetes. CGM data from 117 pregnant women (89 women with type 1 diabetes; 28 women with type 2 diabetes) were analysed. Average glucose levels were calculated from 5–7 day CGM profiles (mean 1275 glucose values per profile) and paired with a corresponding (±1 week) HbA 1c measure. In total, 688 average glucose–HbA 1c pairs were obtained across pregnancy (mean six pairs per participant). Average glucose level was used as the dependent variable in a regression model. Covariates were gestational week, study centre and HbA 1c . There was a strong association between HbA 1c and average glucose values in pregnancy (coefficient 0.67 [95% CI 0.57, 0.78]), i.e. a 1% (11 mmol/mol) difference in HbA 1c corresponded to a 0.67 mmol/l difference in average glucose. The random effects model that included gestational week as a curvilinear (quadratic) covariate fitted best, allowing calculation of a pregnancy-specific eAG (PeAG). This showed that an HbA 1c of 8.0% (64 mmol/mol) gave a PeAG of 7.4–7.7 mmol/l (depending on gestational week), compared with a standard eAG of 10.2 mmol/l. The PeAG associated with maintaining an HbA 1c level of 6.0% (42 mmol/mol) during pregnancy was between 6.4 and 6.7 mmol/l, depending on gestational week. The HbA 1c –average glucose relationship is altered by pregnancy. Routinely generated standard eAG values do not account for this difference between pregnant and non-pregnant individuals and, thus, should not be used during pregnancy. Instead, the PeAG values deduced in the current study are recommended for antenatal clinical care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00125-017-4205-7

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Average glucose against HbA1c in diabetes. A graph showing average glucose vs HbA1c with a linear fit and 95% CI. White circles, women with type 1 diabetes; black circles, women with type 2 diabetes. To convert values for HbA1c in % into mmol/mol, subtract 2.15 and multiply by 10.929
Fig. 1 Average glucose against HbA1c in diabetes. A graph showing average glucose vs HbA1c with a linear fit and 95% CI. White circles, women with type 1 diabetes; black circles, women with type 2 diabetes. To convert values for HbA1c in % into mmol/mol, subtract 2.15 and multiply by 10.929CC BY · PubMed Central
Fig. 2 Changes in PeAG during gestation calculated for a range of HbA1c using the best-fitting model. Long dash, 5.0% (31 mmol/mol) HbA1c; dash/dot, 6.0% (42 mmol/mol) HbA1c; solid line, 7.0% (53 mmol/mol) HbA1c; short dash, 8.0% (64 mmol/mol) HbA1c
Fig. 2 Changes in PeAG during gestation calculated for a range of HbA1c using the best-fitting model. Long dash, 5.0% (31 mmol/mol) HbA1c; dash/dot, 6.0% (42 mmol/mol) HbA1c; solid line, 7.0% (53 mmol/mol) HbA1c; short dash, 8.0% (64 mmol/mol) HbA1cCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. World Health Organization (2011) Use of glycated haemoglobin (HbA1c) in the diagnosis of diabetes mellitus. Abbreviated report of a WHO consultation 2011. Available from www.who.int/diabetes/publications/report-hba1c_2011.pdf. Accessed 5 Aug 2016 26158184

Cited by

See all 79

Metadata

Authors
Law, G. R., Gilthorpe, M. S., Secher, A. L., Temple, R., Bilous, R., Mathiesen, E. R., Murphy, H. R., & Scott, E. M.
Affiliations
  • University of Lincoln (GB)
  • University of Leeds (GB)
  • University of Copenhagen (DK)
  • Norfolk and Norwich University Hospital (GB)
  • Newcastle University Medicine Malaysia (MY)
  • University of East Anglia (GB)
Corresponding author
Scott, Eleanor M.
Venue
Diabetologia
Published
2017-01-19
Volume
60
Issue
4
Pages
618-624
ISSN
  • 0012-186X (ISSN-L)
  • 1432-0428
OpenAlex
W2574692084
Cited by
77
References
30
Citations by year
2026: 3 · 2025: 6 · 2024: 8 · 2023: 8 · 2022: 11 · 2021: 12 · 2020: 10 · 2019: 7 · 2018: 8 · 2017: 4
FWCI
9.34
Type
journal article
Language
en
Open access
Locations
  • Diabetologia (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, cc-by)
  • Lincoln Repository (University of Lincoln) (acceptedVersion)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
  • UEA Digital Repository (University of East Anglia) (acceptedVersion, cc-by)
  • Figshare (submittedVersion, cc-by)
  • Newcastle University ePrints (Newcastle Univesity) (cc-by)
Funders
University of Leeds
Topics
  • Health Sciences › Medicine › Obstetrics and Gynecology › Gestational Diabetes Research and Management
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes, Cardiovascular Risks, and Lipoproteins
Keywords
HbA1c, estimated average glucose, pregnancy, gestational diabetes mellitus, type 1 diabetes, type 2 diabetes, continuous glucose monitoring, average glucose, prenatal care
MeSH terms
Adolescent, Adult, Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Middle Aged, Pregnancy, Blood Glucose Self-Monitoring, Perinatal Care, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.