CoChat

Closed-loop glucose control in young people with type 1 diabetes during and after unannounced physical activity: a randomised controlled crossover trial

Open access
Dovc, Klemen, Macedoni, Maddalena, Bratina, Natasa, Lepej, Dusanka, Nimri, Revital, Atlas, Eran, Muller, Ido, Kordonouri, Olga, Biester, Torben, Danne, Thomas, Phillip, Moshe, Battelino, Tadej · 2017 · Diabetologia
Cited by 85

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

AIMS/HYPOTHESIS: Hypoglycaemia during and after exercise remains a challenge. The present study evaluated the safety and efficacy of closed-loop insulin delivery during unannounced (to the closed-loop algorithm) afternoon physical activity and during the following night in young people with type 1 diabetes. METHODS: A randomised, two-arm, open-label, in-hospital, crossover clinical trial was performed at a single site in Slovenia. The order was randomly determined using an automated web-based programme with randomly permuted blocks of four. Allocation assignment was not masked. Children and adolescents with type 1 diabetes who were experienced insulin pump users were eligible for the trial. During four separate in-hospital visits, the participants performed two unannounced exercise protocols: moderate intensity (55% of [Formula: see text]) and moderate intensity with integrated high-intensity sprints (55/80% of [Formula: see text]), using the same study device either for closed-loop or open-loop insulin delivery. We investigated glycaemic control during the exercise period and the following night. The closed-loop insulin delivery was applied from 15:00 h on the day of the exercise to 13:00 h on the following day. RESULTS: 7.7 ± 0.6% [60.0 ± 6.6 mmol/mol]) were included in the trial and performed all trial-mandated activities. The median proportion of time spent in hypoglycaemia below 3.3 mmol/l was 0.00% for both treatment modalities (p = 0.7910). Use of the closed-loop insulin delivery system increased the proportion of time spent within the target glucose range of 3.9-10 mmol/l when compared with open-loop delivery: 84.1% (interquartile range 70.0-85.5) vs 68.7% (59.0-77.7), respectively (p = 0.0057), over the entire study period. This was achieved with significantly less insulin delivered via the closed-loop (p = 0.0123). CONCLUSIONS/INTERPRETATION: Closed-loop insulin delivery was safe both during and after unannounced exercise protocols in the in-hospital environment, maintaining glucose values mostly within the target range without an increased risk of hypoglycaemia. TRIAL REGISTRATION: Clinicaltrials.gov NCT02657083 FUNDING: University Medical Centre Ljubljana, Slovenian National Research Agency, and ISPAD Research Fellowship.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00125-017-4395-z

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 85

Metadata

Authors
Dovc, K., Macedoni, M., Bratina, N., Lepej, D., Nimri, R., Atlas, E., Muller, I., Kordonouri, O., Biester, T., Danne, T., Phillip, M., & Battelino, T.
Venue
Diabetologia
Published
2017-08-24
Volume
60
Issue
11
Pages
2157-2167
ISSN
  • 0012-186X (ISSN-L)
  • 1432-0428
OpenAlex
W2749586080
Cited by
85
References
6
FWCI
7.05
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Closed-loop glucose control in young people with type 1 diabetes during and after unannounced physical activity: a randomised controlled crossover trial. https://app.cochat.ai/papers/10.1007/s00125-017-4395-z
The paper
Dovc, K., Macedoni, M., Bratina, N., Lepej, D., Nimri, R., Atlas, E., Muller, I., Kordonouri, O., Biester, T., Danne, T., Phillip, M., & Battelino, T. (2017). Closed-loop glucose control in young people with type 1 diabetes during and after unannounced physical activity: a randomised controlled crossover trial. Diabetologia. https://doi.org/10.1007/s00125-017-4395-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.