Tight glycemic control and computerized decision-support systems: a systematic review
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To identify and summarize characteristics of computerized decision-support systems (CDSS) for tight glycemic control (TGC) and to review their effects on the quality of the TGC process in critically ill patients. METHODS: We searched Medline (1950-2008) and included studies on critically ill adult patients that reported original data from a clinical trial or observational study with a main objective of evaluating a given TGC protocol with a CDSS. RESULTS: Seventeen articles met the inclusion criteria. Eleven out of seventeen studies evaluated the effect of a new TGC protocol that was introduced simultaneously with a CDSS implementation. Most of the reported CDSSs were stand-alone, were not integrated in any other clinical information systems and used the "passive" mode requiring the clinician to ask for advice. Different implementation sites, target users, and time of advice were used, depending on local circumstances. All controlled studies reported on at least one quality indicator of the blood glucose regulatory process that was improved by introducing the CDSS. Nine out of ten controlled studies either did not report on the number of hypoglycemia events (one study), or reported on no change (six studies) or even a reduction in this number (two studies). CONCLUSIONS: While most studies evaluating the effect of CDSS on the quality of the TGC process found improvement when evaluated on the basis of the quality indicators used, it is impossible to define the exact success factors, because of simultaneous implementation of the CDSS with a new or modified TGC protocol and the hybrid solutions used to integrate the CDSS into the clinical workflow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639 · cited 2×
“[1 0 ] 2 ,3 9 8 p at ie n ts , p ro g re ss iv e ca re u n it an d m ix ed m ed ic al -s u rg ic a l IC U .”
BackgroundExternal validity of randomised controlled trials: “To whom do the results of this trial apply?”
Rothwell, P. M. (2005) · The Lancet · doi:10.1016/s0140-6736(04)17670-8 · Cited by 2,544 · cited 1×
“Applying the results of highly controlled clinical trials like those evaluating TGC to everyday practice is difficult [20].”
BackgroundBenefits and Risks of Tight Glucose Control in Critically Ill Adults: A Meta-analysis
Wiener, R. S., Wiener, D. C., & Larson, R. J. (2008) · JAMA · doi:10.1001/jama.300.8.933 · Cited by 200 · cited 1×
“This finding is in contrast with some studies, including a recent meta-analysis [ 18 ], showing that TGC implementation increased the risk of hypoglycemia events.”
ResultEvaluation of Outpatient Computerized Physician Medication Order Entry Systems: A Systematic Review
Eslami, S., Abu-Hanna, A., & de Keizer, N. F. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2238 · Cited by 200 · cited 2×
“Showing many pop-up reminders usually irritates users, resulting in the alerts being ignored [5, 6].”
BackgroundMethodSelf-citationTight glycaemic control by an automated algorithm with time-variant sampling in medical icu patients
Pachler, C., Plank, J., Weinhandl, H., Chassin, L. J., Wilinska, M. E., Kulnik, R., Kaufmann, P., Smolle, K.-H., Pilger, E., Pieber, T. R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1033-8 · Cited by 82 · cited 3×
“One article [15, 16] Hypoglycemia-related indicator ( proxy for safety ) Hypoglycemia events \ 40 [7, 9, 15, 22, 23, 25, 27], B 40 [9, 22, 25, 28], \ 50 [7, 10, 11, 26], \ 60 [7, 24], and \ 70 [25] were used as thresholds for defining a BGL as hypoglycemia event.”
BackgroundMethodHermayer, K. L., Neal, D. E., Hushion, T. V., Irving, M. G., Arnold, P. C., Kozlowski, L., Stroud, M. R., Kerr, F. B., & Kratz, J. M. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0225 · Cited by 38
Cited by
The Impact of eHealth on the Quality and Safety of Health Care: A Systematic Overview
Black, A. D., Car, J., Pagliari, C., Anandan, C., Cresswell, K., Bokun, T., McKinstry, B., Procter, R., Majeed, A., & Sheikh, A. (2011) · PLoS Medicine · doi:10.1371/journal.pmed.1000387 · Cited by 1,442
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Ryan, R. E., Santesso, N., Lowe, D., Hill, S., Grimshaw, J. M., Prictor, M., Kaufman, C., Cowie, G., & Taylor, M. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007768.pub3 · Cited by 273
Metadata
- Authors
- Eslami, S., Abu-Hanna, A., de Jonge, E., & de Keizer, N. F.
- Venue
- Intensive Care Medicine
- Published
- 2009-06-27
- Volume
- 35
- Issue
- 9
- Pages
- 1505-1517
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- OpenAlex
- W2167826406
- Cited by
- 64
- References
- 6
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tight glycemic control and computerized decision-support systems: a systematic review. https://app.cochat.ai/papers/10.1007/s00134-009-1542-0
- The paper
- Eslami, S., Abu-Hanna, A., de Jonge, E., & de Keizer, N. F. (2009). Tight glycemic control and computerized decision-support systems: a systematic review. Intensive Care Medicine. https://doi.org/10.1007/s00134-009-1542-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.