Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 575

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Lower tidal volume strategy (≈3 ml/kg) combined with extracorporeal CO2 removal versus ‘conventional’ protective ventilation (6 ml/kg) in severe ARDS: The prospective randomized Xtravent-study

Open access
Bein, Thomas, Weber-Carstens, Steffen, Goldmann, Anton, Müller, Thomas, Staudinger, Thomas, Brederlau, Jörg, Muellenbach, Ralf, Dembinski, Rolf, Graf, Bernhard M., Wewalka, Marlene, Philipp, Alois, Wernecke, Klaus-Dieter, Lubnow, Matthias, Slutsky, Arthur S.·2013·Intensive Care Medicine

Abstract

BACKGROUND: Acute respiratory distress syndrome is characterized by damage to the lung caused by various insults, including ventilation itself, and tidal hyperinflation can lead to ventilator induced lung injury (VILI). We investigated the effects of a low tidal volume (V(T)) strategy (V(T) ≈ 3 ml/kg/predicted body weight [PBW]) using pumpless extracorporeal lung assist in established ARDS. METHODS: Seventy-nine patients were enrolled after a 'stabilization period' (24 h with optimized therapy and high PEEP). They were randomly assigned to receive a low V(T) ventilation (≈3 ml/kg) combined with extracorporeal CO2 elimination, or to a ARDSNet strategy (≈6 ml/kg) without the extracorporeal device. The primary outcome was the 28-days and 60-days ventilator-free days (VFD). Secondary outcome parameters were respiratory mechanics, gas exchange, analgesic/sedation use, complications and hospital mortality. RESULTS: Ventilation with very low V(T)'s was easy to implement with extracorporeal CO2-removal. VFD's within 60 days were not different between the study group (33.2 ± 20) and the control group (29.2 ± 21, p = 0.469), but in more hypoxemic patients (PaO2/FIO2 ≤150) a post hoc analysis demonstrated significant improved VFD-60 in study patients (40.9 ± 12.8) compared to control (28.2 ± 16.4, p = 0.033). The mortality rate was low (16.5%) and did not differ between groups. CONCLUSIONS: The use of very low V(T) combined with extracorporeal CO2 removal has the potential to further reduce VILI compared with a 'normal' lung protective management. Whether this strategy will improve survival in ARDS patients remains to be determined (Clinical trials NCT 00538928).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00134-012-2787-6

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 575

Metadata

Authors
Bein, T., Weber-Carstens, S., Goldmann, A., Müller, T., Staudinger, T., Brederlau, J., Muellenbach, R., Dembinski, R., Graf, B. M., Wewalka, M., Philipp, A., Wernecke, K.-D., Lubnow, M., & Slutsky, A. S.
Venue
Intensive Care Medicine
Published
2013-01-10
Volume
39
Issue
5
Pages
847-856
ISSN
  • 0342-4642 (ISSN-L)
  • 1432-1238
OpenAlex
W1976284065
Cited by
575
References
4
FWCI
44.82
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lower tidal volume strategy (≈3 ml/kg) combined with extracorporeal CO2 removal versus ‘conventional’ protective ventilation (6 ml/kg) in severe ARDS: The prospective randomized Xtravent-study. https://app.cochat.ai/papers/10.1007/s00134-012-2787-6
The paper
Bein, T., Weber-Carstens, S., Goldmann, A., Müller, T., Staudinger, T., Brederlau, J., Muellenbach, R., Dembinski, R., Graf, B. M., Wewalka, M., Philipp, A., Wernecke, K.-D., Lubnow, M., & Slutsky, A. S. (2013). Lower tidal volume strategy (≈3 ml/kg) combined with extracorporeal CO2 removal versus ‘conventional’ protective ventilation (6 ml/kg) in severe ARDS: The prospective randomized Xtravent-study. Intensive Care Medicine. https://doi.org/10.1007/s00134-012-2787-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.