Quantitative ultrasound of the heel and fracture risk assessment: an updated meta-analysis
The DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
Unlabelled Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“quantitative ultrasound predicts fracture risk independently of DXA, and musculoskeletal ultrasound assesses sarcopenia [155,156].”
From Interorgan Communications in Skeletal Pathophysiology: From Molecular Pathways to Multidisciplinary Therapies (2026) · cites this paper as [155]
In the citing paper
“quantitative ultrasound predicts fracture risk independently of DXA, and musculoskeletal ultrasound assesses sarcopenia [155,156].”
From Interorgan Communications in Skeletal Pathophysiology: From Molecular Pathways to Multidisciplinary Therapies (2026) · cites this paper as [155]
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 1×
“Heterogeneity among studies was estimated using the I-squared statistic, which describes the percentage of total variation across studies that is caused by heterogeneity rather than to chance [23].”
MethodOperating characteristics of a rank correlation test for publication bias
Begg, C. B., & Mazumdar, M. (1994) · Biometrics · doi:10.2307/2533446 · Cited by 16,955 · cited 1×
“Inversevariance weights for the included studies were calculated and potential for publication bias was evaluated using funnel plots derived from the Begg–Mazumdar test [22].”
Method(1994) · PubMed · Cited by 5,117
Marshall, D., Johnell, O., & Wedel, H. (1996) · BMJ · doi:10.1136/bmj.312.7041.1254 · Cited by 3,709
ASSESSMENT OF FRACTURE RISK AND ITS APPLICATION TO SCREENING FOR POSTMENOPAUSAL OSTEOPOROSIS
Alexeeva, L. P., Burkhardt, P., Christiansen, C., Cooper, C. C., Delmas, P. D., Johnell, O., Johnston, C. C., Kanis, J. A., Lips, P. T. A. M., Melton, L. J., et al. (1994) · Cited by 2,655
Bauer, D. C. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440270067006 · Cited by 800
Guidelines for diagnosis and management of osteoporosis
Kanis, J. A., Delmas, P., Burckhardt, P., Cooper, C., & Torgerson, D. (1997) · Osteoporosis International · doi:10.1007/bf01623782 · Cited by 790
The Measurement of Broadband Ultrasonic Attenuation in Cancellous Bone
Langton, C. M., Palmer, S. B., & Porter, R. W. (1984) · Engineering in Medicine · doi:10.1243/emed_jour_1984_013_022_02 · Cited by 672 · cited 1×
“QUS is a technology which was first introduced in 1984 [9].”
BackgroundEngelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
Self-citationQuantitative computed tomography
Adams, J. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.04.074 · Cited by 458 · cited 1×
“The introduction of other quantitative technologies (quantitative computed tomography [QCT] [4] and quantitative ultrasound [QUS]) [5] applicable to different central and peripheral skeletal sites, along with the absence of technology-specific guidelines, has created great uncertainty in applying the results of such t…”
BackgroundSelf-citation
Cited by
Items 101–200 of 293
Esmaeilzadeh, S., Cesme, F., Oral, A., Yalıman, A., & Sindel, D. (2016) · Endocrine Research · doi:10.3109/07435800.2015.1120744 · Cited by 17
“Indeed, BUA showed greater AUCs than those of the femoral neck or total hip BMD and other QUS variables showed similar AUCs to those of the DXA BMD in the present study, supporting the findings/conclusions of meta-analyses as to the strong HF predictive ability of QUS variables as well as consideration of calcaneal QU…”
ResultMurphy, C. H., Duggan, E., Davis, J. R. C., O’Halloran, A. M., Knight, S. P., Kenny, R. A., McCarthy, S. N., & Romero‐Ortuño, R. (2022) · Experimental Gerontology · doi:10.1016/j.exger.2022.112013 · Cited by 17
“associated with calcaneal ultrasound-derived stiffness index, a measure of bone mass that is predictive of fracture risk [55].”
BackgroundLow Circulating Valine Associate With High Risk of Hip Fractures
Grahnemo, L., Eriksson, A. L., Nethander, M., Johansson, R., Lorentzon, M., Mellström, D., Pettersson, U., & Ohlsson, C. (2023) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad268 · Cited by 17
“Fracture Risk is Modestly Reduced by Adjustment for eBMD eBMD is a robust negative predictor of fracture risk (37), and measurement of eBMD was available for a majority of the subjects with valine measurements in the UK Biobank.”
Screen Time and Bone Status in Children and Adolescents: A Systematic Review
de Lamas, C., Sánchez‐Pintos, P., de Castro, M. J., de Pipaón, M. S., & Couce, M. L. (2021) · Frontiers in Pediatrics · doi:10.3389/fped.2021.675214 · Cited by 17
“While the current gold standard for measuring BMD is DEXA, this method is costly, involves ionizing radiation, and requires a highly trained operator (31).”
BackgroundUgarph-Morawski, A., Sääf, M., & Brismar, K. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.109064 · Cited by 17
Fractures in hospitalized children
Huh, S. Y., & Gordon, C. M. (2012) · Metabolism · doi:10.1016/j.metabol.2012.07.018 · Cited by 17
“A meta-analysis of 21 prospective studies in elderly adults showed that 4 different QUS measures at the heel correlated with fracture risk [74].”
BackgroundSu, Y., Lai, F. T. T., Yip, B. H. K., Leung, J. C. S., & Kwok, T. C. Y. (2018) · Osteoporosis International · doi:10.1007/s00198-018-4543-4 · Cited by 16
“While the utility of QUS for osteoporotic fractures was widely identified [13, 43], the QUS measurement of the calcaneus before performing the DXA test might be another accepted alternative strategy for older people in the areas with limited DXA access.”
BackgroundCronholm, F., Lindgren, E., Rosengren, B. E., Dencker, M., Karlsson, C., & Karlsson, M. K. (2020) · Sports · doi:10.3390/sports8040040 · Cited by 16
Assessment of Skeletal Strength
Lewiecki, E. M. (2021) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2021.03.008 · Cited by 16
Self-citationAli, M., Uddin, Z., & Hossain, A. (2021) · Osteology · doi:10.3390/osteology1040018 · Cited by 16
“A systematic review and meta-analysis confirmed that QUS significantly predicts the RO and various fracture outcomes for adult men and women [16].”
BackgroundImaging Techniques to Study Diabetic Bone Disease
Carballido-Gamio, J. (2022) · Current Opinion in Endocrinology, Diabetes & Obesity · doi:10.1097/med.0000000000000749 · Cited by 12
Zhang, L., Lv, H., Zheng, H., Li, M., Yin, P., Ye, P., Gao, Y., Zhang, L., & Tang, P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0145879 · Cited by 16
“also determined that the BUA, SOS, and stiffness were significantly associated with fracture risk [10].”
BackgroundGonçalves, E. M., Ribeiro, R. R., de Carvalho, W. R. G., de Moraes, A. M., Roman, E. P., Santos, K. D., Medaets, P. A. R., Veiga-Junior, N. N., Coelho, A. C. L. D. M., Krahenbühl, T., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0127294 · Cited by 15
Määttä, M. (2012) · Cited by 15
Ding, Z., Chen, Y., Xu, Y., Zhou, X., Xu, Y., Ma, Z., & Sun, Y. (2016) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2016.11.001 · Cited by 15
“Quantitative ultrasound (QUS) measurement has become an important modality for the assessment of osteoporosis status and the estimate of osteoporotic fracture risk (3,4).”
Nowakowska-Płaza, A., Wroński, J., Płaza, M., Sudoł‐Szopińska, I., & Głuszko, P. (2021) · Polskie Archiwum Medycyny Wewnętrznej · doi:10.20452/pamw.16046 · Cited by 15
“Techniques of quantitative ultrasound (QUS) of bone density have been studied for many years and meta-analysis of these studies showed the value of QUS in predicting fractures[10].”
ResultJiang, Y., Zhuo, B. M. K., Guo, B., Zeng, P., Guo, Y., Chen, G., Wei, J., He, R., Li, Z., Zhang, X., et al. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.155393 · Cited by 15
Zulfarina, M. S., Sharif, R., Syarifah-Noratiqah, S.-B., Ahmad, M. S., Aqilah-S.N, Z.-S., Mokhtar, S.-A., Shuid, A. N., & Naina-Mohamed, I. (2018) · PLoS ONE · doi:10.1371/journal.pone.0202321 · Cited by 16
Correa‐Rodríguez, M., Schmidt‐RioValle, J., González‐Jiménez, E., & Rueda‐Medina, B. (2015) · Calcified Tissue International · doi:10.1007/s00223-015-0086-2 · Cited by 14
“QUS, including broadband ultrasound attenuation (BUA), is a non-invasive technique useful in assessing bone structure and bone mass and provides determinants of bone structure beyond those associated with DXA [22].”
InfluentialTsourdi, E. A., Wallaschofski, H., Rauner, M., Nauck, M. A., Pietzner, M., Rettig, R., Ittermann, T., Völzke, H., Völker, U., Hofbauer, L. C., et al. (2015) · Osteoporosis International · doi:10.1007/s00198-015-3276-x · Cited by 13
“Ultrasound measurements at the calcaneus correlate highly with BMD and biomechanical properties at the same site [12], and a recent meta-analysis validated QUS as a reliable tool for assessing fracture risk [13].”
BackgroundFracture Risk in Chronic Kidney Disease: Addressing an Overlooked Complication
Gembillo, G., Sessa, C., Morale, W., Zanoli, L., Catalano, A., Silipigni, S., Soraci, L., Corsonello, A., Princiotto, M., Lomonte, C., et al. (2025) · Metabolites · doi:10.3390/metabo15070460 · Cited by 13
“Literature studies have demonstrated a correlation between osteoporotic fracture risk and decreased ultrasound cortical speed in a normal population and in dialysis patients with secondary hyperparathyroidism [49,50].”
Cesme, F., Esmaeilzadeh, S., & Oral, A. (2016) · Acta Orthopaedica et Traumatologica Turcica · doi:10.1016/j.aott.2016.08.006 · Cited by 12
Pisani, P., Conversano, F., Chiriacò, F., Quarta, E., Quarta, L., Muratore, M., Lay-Ekuakille, A., & Casciaro, S. (2016) · Measurement · doi:10.1016/j.measurement.2016.08.014 · Cited by 12
Sadoughi, S., Bevill, G. R., Morgan, E. F., Palepu, V., Keaveny, T. M., & Wear, K. A. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2022.2069465 · Cited by 12
“Because of its proximity to the skin, the calcaneus is also a good site for CONTACT Keith A. Wear keith.wear@fda.hhs.gov 2022 Informa UK Limited, trading as Taylor & Francis Group photoacoustic measurements, which provide chemical constituent information that offers promise for complementing calcaneal QUS (Feng et al.…”
BackgroundInfluentialMezzaroma, I., Fantauzzi, A., Ceci, F., Cacciatore, F., Vullo, V., & Floridia, M. (2016) · HIV/AIDS - Research and Palliative Care · doi:10.2147/hiv.s99904 · Cited by 12
Quester, J., Nethander, M., Eriksson, A. L., & Ohlsson, C. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab915 · Cited by 13
“687) as analysed by Quantitative ultrasound of the heel (38).”
MethodPotter, M. D. E., Walker, M. M., Hancock, S., Holliday, E. G., Brogan, G., Jones, M., McEvoy, M., Boyle, M., Talley, N. J., & Attia, J. (2018) · Nutrients · doi:10.3390/nu10070849 · Cited by 12
“Although quantitative heel ultrasound performs well against DXA in predicting fracture risk [51,52], it generally underestimates bone mineral density when compared with DXA, with lower sensitivity (21–45%) but high specificity (87–96%) at a cut-off of −2.”
BackgroundSharma, D., Cheok, T. S., Rogers, M., Lu, V., Solomon, L. B., Ramasamy, B., Clifton, P. M., & Callary, S. A. (2025) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2025.06.034 · Cited by 12
Ali, K., Said, S. M. S. E., Adly, N. N., & Rahman, S. (2020) · Journal of Multidisciplinary Healthcare · doi:10.2147/jmdh.s230730 · Cited by 11
Sohl, E., de Jongh, R. T., Swart, K. M. A., Enneman, A. W., van Wijngaarden, J. P., van Dijk, S. C., Ham, A. C., van der Zwaluw, N. L., Brouwer-Brolsma, E. M., van der Velde, N., et al. (2014) · Calcified Tissue International · doi:10.1007/s00223-014-9943-7 · Cited by 12
“QUS parameters are associated with bone mineral density and both predict fracture risk [16, 17].”
BackgroundGrigoriou, E., Trovas, G., Παπαϊωάννου, Ν., Dontas, I. A., Makris, K., Apostolou-Karampelis, K., & Dedoussis, G. V. (2020) · Nutrients · doi:10.3390/nu12010123 · Cited by 12
“Although BMD is the main predictive risk factor for an osteoporotic fracture, measurement of quantitative ultrasound (QUS) has been found to be associated with bone fragility and increased fracture risk [27].”
BackgroundPulse-echo ultrasound measurement in osteoporosis screening: a pilot study in older patients
Dovjak, P., Iglseder, B., Rainer, A., Dovjak, G. O., Weber, M., & Pietschmann, P. (2023) · Aging Clinical and Experimental Research · doi:10.1007/s40520-023-02404-z · Cited by 11
Bazika-Gerasch, B., Maier, C., Kumowski, N., Fiege, C., Kaisler, M., Vollert, J., & Dietrich, J. W. (2019) · Pain · doi:10.1097/j.pain.0000000000001520 · Cited by 11
“mean 6 SD (range) 38 6 39 (4-156) 58 6 73 (3-342) 0.”
Böker, J., Völzke, H., Nauck, M. A., Hannemann, A., & Friedrich, N. (2018) · Clinical Endocrinology · doi:10.1111/cen.13588 · Cited by 10
Correa‐Rodríguez, M., Schmidt‐RioValle, J., & Rueda‐Medina, B. (2018) · International Journal of Medical Sciences · doi:10.7150/ijms.25369 · Cited by 10
“To date, most candidate gene and genome-wide association studies (GWAS) examining the genetic factors influencing bone phenotype parameters have been focused on BMD assessed by DXA [9, 10].”
BackgroundInfluentialLu, H., Hung, K., Chu, H., Wong, H. S.-C., Kim, J., Kim, M. K., Choi, B. Y., Tai, Y., Ikegawa, S., Cho, E.-C., et al. (2019) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3703 · Cited by 10
“We scored each gene using the following criteria: (1) contained nonsynonymous variant(s) associated with the SI; (2) contained eQTL(s); (3) belonged to an enriched GO biological process; (4) belonged to an enriched GWAS catalog phenotype; (5) had PPI annotations; and (6) contained SNP(s) that had potential within DNA-…”
Quantitative assessment of damage during MCET: a parametric study in a rodent model
Zhu, Y. I., Miller, D. L., Dou, C., Lu, X., & Kripfgans, O. D. (2015) · Journal of Therapeutic Ultrasound · doi:10.1186/s40349-015-0039-2 · Cited by 9
“Quantitative ultrasound has been employed in diagnosis of osteoporosis [11], as well as in at-risk pregnancies with three-dimensional sonographic measurement of blood volume flow in umbilical cords [12].”
MethodYamakita, M., Ando, D., Akiyama, Y., Sato, M., Suzuki, K., & Yamagata, Z. (2019) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-019-01021-z · Cited by 9
Genetic Determinants and Pharmacogenetics of Osteoporosis and Osteoporotic Fracture
Hsu, Y., Xu, X., & Jeong, S. (2020) · Contemporary Endocrinology · doi:10.1007/978-3-319-69287-6_25 · Cited by 9
Pulse-Echo Measurements of Bone Tissues. Techniques and Clinical Results at the Spine and Femur
Ciardo, D., Pisani, P., Conversano, F., & Casciaro, S. (2022) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-91979-5_7 · Cited by 9
Validation of an automatic segmentation method to detect vertebral interfaces in ultrasound images
Aventaggiato, M., Conversano, F., Pisani, P., Casciaro, E., Franchini, R., Lay-Ekuakille, A., Muratore, M., & Casciaro, S. (2015) · IET Science Measurement & Technology · doi:10.1049/iet-smt.2015.0042 · Cited by 9
Analysis of SNP-SNP interactions and bone quantitative ultrasound parameter in early adulthood
Correa‐Rodríguez, M., Viatte, S., Massey, J., Schmidt‐RioValle, J., Rueda‐Medina, B., & Orozco, G. (2017) · BMC Medical Genetics · doi:10.1186/s12881-017-0468-6 · Cited by 9
“BMD: Bone mineral density; BMI: Body mass index; BUA: Broadband ultrasound attenuation; CIs: Confidence intervals; DCI: Dietary calcium intake; DXA: Dual-energy x-ray absorptiometry; GWAS: Genome wide association studies; HWE: Hardy-Weinberg equilibrium; IPAQ: International Physical Activity Questionnaire; MAF: Minor…”
BackgroundInfluentialPatel, H., Woods, L., Teesdale‐Spittle, P. H., & Dennison, E. M. (2021) · The Physician and Sportsmedicine · doi:10.1080/00913847.2021.1903819 · Cited by 10
“It has been shown to be able to discern the risk of fragility fracture in older adults [14,15], with the cQUS bone outcomes stiffness index (SI)”
BackgroundHwang, J., Kim, Y. J., Choi, B. Y., Kim, B.-J., & Han, B. (2015) · Bone · doi:10.1016/j.bone.2015.12.005 · Cited by 9
Cronholm, F., Rosengren, B. E., Nilsson, J., Ohlsson, C., Mellström, D., Ribom, E. L., & Karlsson, M. K. (2019) · BMC Geriatrics · doi:10.1186/s12877-019-1106-2 · Cited by 8
Correa‐Rodríguez, M., Schmidt‐RioValle, J., & Rueda‐Medina, B. (2017) · Nutrición Hospitalaria · doi:10.20960/nh.468 · Cited by 8
“It should be noted that both previous studies used DXA for measurements of bone mass, none of them used calcaneal ultrasound, and hence, we could not compare our effect sizes for BUA.”
MethodRoberts, J. A., Shen, Y., Strehlau, R., Patel, F., Kuhn, L., Coovadia, A. H., Kaufman, J. J., Shiau, S., Arpadi, S. M., & Yin, M. T. (2022) · PLoS ONE · doi:10.1371/journal.pone.0276290 · Cited by 8
“of bone through which the ultrasound beam passes but also the physical arrangement, or micro-architecture, of the bone [33, 34], which may also partially explain why BUA is a better predictor of fracture risk than DXA in some populations [7, 35].”
BackgroundKauppi, M. J., Impivaara, O., Mäki, J., Heliövaara, M., & Jula, A. M. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2355-0 · Cited by 8
“However, according to a recent meta-analysis based on prospective studies, QUS devices from various manufacturers appear to predict risks of hip and other fractures with similar performance in elderly people, both men and women [18].”
BackgroundResultInfluentialAlomari, A., Wille, M., & Langton, C. M. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa7b47 · Cited by 8
“…has been demonstrated to provide a reliable prediction of © 2017 IOPPublishing Ltd osteoporotic fracture risk (Hans et al 1996, Bauer et al 1997, Thompson et al 1998, Njeh et al 2000, Moayyeri et al 2012); being simpler to use, free from ionising radiation, lower cost and portable compared to DXA.”
Heel quantitative ultrasound in HIV-infected patients: a cross-sectional study
Pinzone, M. R., Castronuovo, D., Gregorio, A. D., Celesia, B. M., Gussio, M., Borderi, M., Maggi, P., Santoro, C. R., Madeddu, G., Cacopardo, B. S., et al. (2015) · Infection · doi:10.1007/s15010-015-0842-2 · Cited by 8
Paunescu, A., Ayotte, P., Dewailly, É., & Dodin, S. (2014) · The journal of nutrition health & aging · doi:10.1007/s12603-014-0461-0 · Cited by 8
Chin, K., Low, N. Y., Kamaruddin, A. A. A., Dewiputri, W. I., & Soelaiman, I. N. (2017) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s145519 · Cited by 8
“They can also predict fracture risk.(8) Although cheaper than DEXA, QUS devices still incur substantial costs and may not be available at all primary health care premises.”
Oh, S. M., Kim, H. C., Rhee, Y., Park, S., Lee, H.-J., Suh, I., & Feskanich, D. (2013) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-013-0427-z · Cited by 8
Moonkum, N., Withayanuluck, T., Somarungsan, A., Sichai, N., Wongsiri, A., Chawkhaodin, W., Ruengdach, P., Boonsuk, P., Pukdeeyorng, M., & Tochaikul, G. (2024) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2024.101470 · Cited by 7
Chen, J., Liang, X., Wang, Y., Dejiquzong, Zhang, Y., Chen, L., Liu, Q., & Zhao, X. (2024) · BMC Public Health · doi:10.1186/s12889-024-20628-0 · Cited by 7
“Nonetheless, studies have shown that QUS possesses similar predictive capabilities for osteo-porotic fractures compared to bone density, and serves as an independent risk factor [37, 69, 70].”
Sonnenfeld, M. M., Pimentel, F. L., Nasser, E. J., Pompei, L. D. M., Fernandes, C. E., & Steiner, M. L. (2022) · Revista Brasileira Ginecologia e Obstetrícia · doi:10.1055/s-0041-1741408 · Cited by 7
“There are, however, studies 3,4 that con fi rm that QUS can predict fractures in elderly women, such as the one by Moayyeri et al. 3 (2012) a meta-analysis with a total follow-up of 279,124 people.”
BackgroundResultBlomqvist, M., Nuotio, M. S., Sääksjärvi, K., BSc, J. P., Koskinen, S. V. P., & Stenholm, S. (2025) · Aging Clinical and Experimental Research · doi:10.1007/s40520-025-03229-8 · Cited by 6
“Additionally, while calcaneal ultrasound-based bone densitometry has been shown to predict fracture risk with similar performance to DXA, there are no agreed criteria for diagnosing osteoporosis using calcaneal ultrasound [22, 23].”
Correa‐Rodríguez, M., Schmidt‐RioValle, J., & Rueda‐Medina, B. (2017) · Annals of Human Genetics · doi:10.1111/ahg.12235 · Cited by 6
“In addition, a recent meta-analysis indicates that QUS is a valuable tool for fracture risk assessment independently of DXA (Huopio et al., 2004; Moayyeri et al., 2012).”
MethodQuantitative Ultrasound of the Heel in Women With Knee Osteoarthritis
Hiyama, Y., Takahashi, R., Tanaka, T., & Misaki, S. (2021) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2021.01.001 · Cited by 6
Antipsychotic medication use in association with quantitative heel ultrasound (QUS)
Manavi, B. A., Mohebbi, M., Stuart, A. L., Pasco, J. A., Hodge, J. M., Weerasinghe, D. K., Samarasinghe, R. M., & Williams, L. J. (2023) · Bone Reports · doi:10.1016/j.bonr.2023.101694 · Cited by 6
Lv, X., Lin, Y., Zhang, Z., Li, B., Zeng, Z., Jiang, X., Zhao, Q., Li, W., Wang, Z., Yang, C., et al. (2023) · BMC Genomics · doi:10.1186/s12864-023-09449-4 · Cited by 6
“In this study, we selected SNPs illustrating the serum levels of ADAM metallopeptidases based on public GWAS results and analyzed their association with FA-BMD, FN-BMD, LS-BMD and eBMD, since DXA measured BMD has been introduced as diagnostic standard of osteoporosis by world health organization, and meta-analysis of…”
MethodDing, W., Huang, Y., Li, G., Dong, Y., Li, X., Wu, M., Song, K., & Li, F. (2023) · Osteoporosis International · doi:10.1007/s00198-023-07004-1 · Cited by 6
“However, this method also has a high sensitivity for detecting bone mineral density [48–50] and has been used in other articles [51–53].”
Wearing, S. C., Hooper, S., Langton, C. M., Keiner, M., Horstmann, T., Crevier‐Denoix, N., & Pourcelot, P. (2024) · Healthcare · doi:10.3390/healthcare12131254 · Cited by 6
Rebocho, L. M., Cardadeiro, G., Zymbal, V., Gonçalves, E. M., Sardinha, L. B., & Baptista, F. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.09.013 · Cited by 6
Iseme, R. A., McEvoy, M., Kelly, B. J., Agnew, L. L., Walker, F. R., Boyle, M., & Attia, J. R. (2018) · Journal of Immunology Research · doi:10.1155/2018/9407971 · Cited by 6
Guglielmi, G., Rossini, M., Nicolosi, M. G., Ragno, A., Lentini, G., & de Terlizzi, F. (2012) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2012.07.006 · Cited by 6
A new ultrasonic method for lumbar spine densitometry
Conversano, F., Casciaro, E., Franchini, R., Soloperto, G., Greco, A., Casciaro, S., Quarta, E., Quarta, L., & Muratore, M. (2013) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2013.0461 · Cited by 6
“As a consequence, the widely accepted physician opinion is that osteoporosis cannot be reliably diagnosed by QUS methods, which can be actually useful only as a preliminary test for nonvertebral fracture risk to be followed by a DXA confirmation [22]-[24].”
BackgroundLes déterminants de santé corrélables à la densité minérale osseuse appréciée par ultrasonométrie
Zakhem, E., Khoury, G. E., Berro, A.-J., Zouhal, H., Khoury, C. E., Theunynck, D., Hurdiel, R., Pezé, T., Zunquin, G., Jacob, C., et al. (2016) · Kinésithérapie la Revue · doi:10.1016/j.kine.2016.01.009 · Cited by 6
Zagórski, P., Tabor, E., Martela, K., Adamczyk, P., Glinkowski, W., & Pluskiewicz, W. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.11.025 · Cited by 6
FGF-2 Gene Polymorphism in Osteoporosis among Guangxi’s Zhuang Chinese
Bin, X., Lin, C., Huang, X., Zhou, Q.-H., Wang, L., & Xian, C. J. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18071358 · Cited by 6
“Calcaneus ultrasound can be used as an effective tool for bone health survey [18] and prediction of fracture risk of senior and middle-aged people [19].”
MethodOono, F., Sakamoto, Y., Tachi, Y., Mabashi-Asazuma, H., & Iida, K. (2020) · Nutrients · doi:10.3390/nu12010191 · Cited by 5
“001) [22], and are able to predict the risk of fracture [23,24].”
BackgroundAlomari, A., Al-Qahtani, S. M., & Langton, C. M. (2021) · Applied Acoustics · doi:10.1016/j.apacoust.2021.108072 · Cited by 5
Personalized fracture risk assessment: where are we at?
Nguyen, T. V. (2021) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2021.1924672 · Cited by 5
“Quantitative ultrasound measurement (QUS) is associated with fracture [56], and PRS generated from QUS can also help”
BackgroundPye, S. R., Vanderschueren, D., Boonen, S., Gielen, E., Adams, J. E., Ward, K. A., Lee, D. M., Bártfai, G., Casanueva, F. F., Finn, J. D., et al. (2015) · Age and Ageing · doi:10.1093/ageing/afv073 · Cited by 5
“Quantitative ultrasound (QUS) is associated with an increased risk of fracture [5, 6]; however, less is known about other adverse outcomes including mortality.”
BackgroundSelf-citationDesbiens, L., Goupil, R., Sidibé, A., Madore, F., & Mac‐Way, F. (2019) · Osteoporosis International · doi:10.1007/s00198-019-04902-1 · Cited by 5
Desbiens, L., Goupil, R., & Mac‐Way, F. (2019) · Bone · doi:10.1016/j.bone.2019.115120 · Cited by 5
Wei, Q., Zhan, J., Chen, X., Huang, Q., Li, H., Guo, W., Liu, Z., Chen, S., & Cai, D. (2025) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-025-03292-1 · Cited by 4
“Although direct comparison with QUS was not possible in our dataset, previous studies have reported that QUS often shows lower sensitivity, ranging from 65% to 75%, compared with DXA [50], which highlights the potential of OP-LM to provide more reliable early risk stratification.”
Pan, W., Shen, Y., & van Lenthe, H. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.02.034 · Cited by 4
Association between vitamin D and bone mineral density in Japanese adults: the Unzen study
Honda, Y., Arima, K., Nishimura, T., Tomita, Y., Mizukami, S., Abe, Y., Tanaka, N., Kojima, M., Jeng, T.-P., Goto, H., et al. (2021) · Archives of Osteoporosis · doi:10.1007/s11657-021-00984-9 · Cited by 4
Hyde, N. K., Brennan-Olsen, S. L., Wark, J. D., Hosking, S., & Pasco, J. A. (2020) · Calcified Tissue International · doi:10.1007/s00223-020-00762-8 · Cited by 4
Kragl, A., Hannemann, A., Nauck, M. A., Völker, U., Siggelkow, H., Teumer, A., & Tzvetkov, M. V. (2023) · Calcified Tissue International · doi:10.1007/s00223-023-01141-9 · Cited by 4
“Nevertheless, QUS measurements allow osteoporotic fracture risk prediction [6].”
BackgroundKaboré, N. F., Eymard‐Duvernay, S., Zoungrana, J., Badiou, S., Bado, G., Héma, A., Diouf, A., Delaporte, É., Koulla‐Shiro, S., Ciaffi, L., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0186686 · Cited by 4
Structural and Metabolic Assessment of Bone
Narla, R. R., & Ott, S. M. (2020) · Handbook of experimental pharmacology · doi:10.1007/164_2020_376 · Cited by 4
Noale, M., Maggi, S., Gonnelli, S., Limongi, F., Zanoni, S., Zambon, S., Rozzini, R., & Crepaldi, G. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.02.022 · Cited by 5
Kauppi, M. (2015) · UTUPub (University of Turku) · Cited by 5
Bone disease in chronic epilepsy: fit for a fracture
Beerhorst, K. (2015) · Research Publications (Maastricht University) · doi:10.26481/dis.20151113kb · Cited by 4
Pines, A. (2012) · Climacteric · doi:10.3109/13697137.2013.749448 · Cited by 4
Ganmaa, D., Khudyakov, P., Buyanjargal, U., Tserenkhuu, E., Erdenenbaatar, S., Achtai, C.-E., Yansan, N., Delgererekh, B., Ankhbat, M., Tsendjav, E., et al. (2023) · medRxiv · doi:10.1101/2023.05.18.23290181 · Cited by 4
Hadadi, I. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1768327 · Cited by 3
Groenendijk, I., Wijnen, H. H., Taekema, D. G., & de Groot, C. P. G. M. (2025) · AIMS Public Health · doi:10.3934/publichealth.2025048 · Cited by 3
“QUS parameters have been correlated with BMD and can predict the risk for a future fracture [20].”
Lanyan, A., Marques-Vidal, P. M., Métrailler, A., Rodríguez, E. G., Hans, D. B., Shevroja, E., & Lamy, O. (2024) · Scientific Reports · doi:10.1038/s41598-024-51774-5 · Cited by 3
Self-citationИгоревна, Н. К., Абрамова, Т. Ф., & Михайловна, Н. Т. (2020) · Human Sport Medicine · doi:10.14529/hsm190406 · Cited by 3
RANKL/RANK/OPG Polymorphisms and Heel Quantitative Ultrasound in Young Adults
Correa‐Rodríguez, M., Schmidt‐RioValle, J., & Rueda‐Medina, B. (2017) · Nursing Research · doi:10.1097/nnr.0000000000000202 · Cited by 3
“measurements are correlated with BMD and are clinically important in providing determinants of bone structure beyond those associated with DXA (Moayyeri et al., 2012).”
BackgroundResultNishimura, T., Arima, K., Abe, Y., Kanagae, M., Mizukami, S., Okabe, T., Tomita, Y., Goto, H., Hasegawa, M., Sou, Y., et al. (2019) · Annals of Human Biology · doi:10.1080/03014460.2019.1607552 · Cited by 3
González-Jorge, A. L., Enciso, S., Reyes, A., Hernández, A. M., Ortiz, L., Aldana, R., Velásquez-Forero, F., Ambrosi, R., Clark, P., Méndez, L., et al. (2016) · Transplantation Proceedings · doi:10.1016/j.transproceed.2016.02.025 · Cited by 3
Lessons from the Bone Chapter of the Malaysian Aging Men Study
Chin, K., Ngah, W. W., & Ima-Nirwana, S. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13060531 · Cited by 3
“34) [107].”
Novel Imaging Modalities in Osteoporosis Diagnosis and Risk Stratification
Haque, S., Lau, A. N., BEATTIE, K. A., & Adachi, J. D. (2018) · Current Treatment Options in Rheumatology · doi:10.1007/s40674-018-0099-x · Cited by 3
Wilhelm, A., Hadji, P., Münzel, M., Daniel, H., Flache, S., Nyarango, P. M., & Kann, P. H. (2016) · Gynecological Endocrinology · doi:10.1080/09513590.2016.1266475 · Cited by 2
“studies have shown its efficacy in predicting fracture risk [15].”
BackgroundUddin, A. M. S., Rahman, H., Barua, S., Alam, M. N., Amin, U. S., Hussain, M. F., & Ali, M. A. (2023) · Journal of Medicine · doi:10.3329/jom.v24i2.67276 · Cited by 2
Nahas, A. R. F., & Sulaiman, S. A. S. (2017) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/jpbs.jpbs_64_17 · Cited by 2
“Based on the recommendations of the International Society of Clinical Densitometry, the only accepted QUS measure for defining clinically the status of bone health is the calcaneal QUS.[20] Besides, the measured calcaneal BMD by QUS was efficient and analogous to the measured hip BMD using DXA in hip fracture predicti…”
Method
Metadata
- Authors
- Moayyeri, A., Adams, J. E., Adler, R. A., Krieg, M.-A., Hans, D., Compston, J., & Lewiecki, E. M.
- Affiliations
- University of Cambridge (GB)
- Manchester Royal Infirmary (GB)
- Virginia Commonwealth University (US)
- Centre Hospitalier Universitaire Vaudois (CH)
- Cambridge University Hospitals NHS Foundation Trust (GB)
- New Mexico Clinical Research & Osteoporosis Center (US)
- Corresponding author
- Lewiecki, E. M.
- Venue
- Osteoporosis International
- Published
- 2011-10-27
- Volume
- 23
- Issue
- 1
- Pages
- 143-153
- ISSN
- 0937-941X (ISSN-L)
- 1433-2965
- OpenAlex
- W1988488550
- Cited by
- 266
- References
- 52
- Citations by year
- 2026: 12 · 2025: 13 · 2024: 9 · 2023: 26 · 2022: 10 · 2021: 17 · 2020: 22 · 2019: 11 · 2018: 24 · 2017: 24 · 2016: 21 · 2015: 21 · 2014: 21 · 2013: 17 · 2012: 17
- FWCI
- 18.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Osteoporosis International (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- IRIS (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- SERVAL (Université de Lausanne) (submittedVersion)
- Funders
- Baoji University of Arts And Sciences
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Surgery › Hip and Femur Fractures
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- quantitative ultrasound, fracture risk prediction, calcaneus, broadband ultrasound attenuation, sound velocity, stiffness index, hip fracture, vertebral fractures, osteoporotic fractures, bone mineral density, elderly men and women, fracture risk assessment tools, device comparison, osteoporosis screening, fracture prevention
- MeSH terms
- Aged, Calcaneus, Female, Humans, Male, Middle Aged, Osteoporosis, Prognosis, Ultrasonography, Absorptiometry, Photon, Bone Density, Osteoporosis, Postmenopausal, Risk Assessment, Osteoporotic Fractures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.