CoChat

Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number

Bhat, Somanath, Herrmann, Jan, Armishaw, Paul, Corbisier, Philippe, Emslie, Kerry R. · 2009 · Analytical and Bioanalytical Chemistry

The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.

Abstract

Digital polymerase chain reaction (PCR) is a promising technique for estimating target DNA copy number. PCR solution is distributed throughout numerous partitions, and following amplification, target DNA copy number is estimated based on the proportion of partitions containing amplified DNA. Here, we identify approaches for obtaining reliable digital PCR data. Single molecule amplification efficiency was significantly improved following fragmentation of total DNA and bias in copy number estimates reduced by analysis of short intact target DNA fragments. Random and independent distribution of target DNA molecules throughout partitions, which is critical to accurate digital PCR measurement, was demonstrated by spatial distribution analysis. The estimated relative uncertainty for target DNA concentration was under 6% when analyzing five digital panels comprising 765 partitions each, provided the panels contained an average of 212 to 3,365 template molecules. Partition volume was a major component of this uncertainty estimate. These findings can be applied to other digital PCR studies to improve confidence in such measurements.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00216-009-2729-5

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Cited by

See all 220

Metadata

Authors
Bhat, S., Herrmann, J., Armishaw, P., Corbisier, P., & Emslie, K. R.
Affiliations
National Measurement Institute (AU)
Corresponding author
Emslie, Kerry R.
Venue
Analytical and Bioanalytical Chemistry
Published
2009-03-15
Volume
394
Issue
2
Pages
457-467
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W1991340669
Cited by
218
References
20
Citations by year
2026: 4 · 2025: 7 · 2024: 11 · 2023: 15 · 2022: 9 · 2021: 9 · 2020: 15 · 2019: 9 · 2018: 18 · 2017: 12 · 2016: 32 · 2015: 19 · 2014: 7 · 2013: 10 · 2012: 16
FWCI
8.21
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Analytical and Bioanalytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Joint Research Centre (European Commission) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
Keywords
digital PCR, DNA copy number, single-molecule detection, amplification efficiency, measurement uncertainty, DNA fragmentation
MeSH terms
Computer Simulation, DNA, Gene Dosage, Oligonucleotide Array Sequence Analysis, Microfluidics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number. https://app.cochat.ai/papers/10.1007/s00216-009-2729-5
The paper
Bhat, S., Herrmann, J., Armishaw, P., Corbisier, P., & Emslie, K. R. (2009). Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-009-2729-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.