Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,055

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification

Open access
Pinheiro, Leonardo B., Coleman, Victoria A., Hindson, Christopher M., Herrmann, Jan, Hindson, Benjamin J., Bhat, Somanath, Emslie, Kerry R.·2012·Analytical Chemistry

Abstract

Droplet digital polymerase chain reaction (ddPCR) is a new technology that was recently commercialized to enable the precise quantification of target nucleic acids in a sample. ddPCR measures absolute quantities by counting nucleic acid molecules encapsulated in discrete, volumetrically defined, water-in-oil droplet partitions. This novel ddPCR format offers a simple workflow capable of generating highly stable partitioning of DNA molecules. In this study, we assessed key performance parameters of the ddPCR system. A linear ddPCR response to DNA concentration was obtained from 0.16% through to 99.6% saturation in a 20,000 droplet assay corresponding to more than 4 orders of magnitude of target DNA copy number per ddPCR. Analysis of simplex and duplex assays targeting two distinct loci in the Lambda DNA genome using the ddPCR platform agreed, within their expanded uncertainties, with values obtained using a lower density microfluidic chamber based digital PCR (cdPCR). A relative expanded uncertainty under 5% was achieved for copy number concentration using ddPCR. This level of uncertainty is much lower than values typically observed for quantification of specific DNA target sequences using currently commercially available real-time and digital cdPCR technologies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac202578x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 10

  1. Sykes P. J., 1992, Biotechniques, 13, 444
  2. Sanders R., 2011, Anal. Chem., 83, 6474, 10.1021/ac103230c · DOI · Paper page
  3. Lo Y. M., 2007, Proc. Natl. Acad. Sci. U.S.A., 104, 13116, 10.1073/pnas.0705765104 · DOI · Paper page
  4. Wang J., 2010, Clin. Chem., 56, 623, 10.1373/clinchem.2009.134973 · DOI
  5. Bhat S., 2010, Anal. Chem., 82, 7185, 10.1021/ac100845m · DOI
  6. Abramoff M. D., 2004, Biophoton. Int., 11, 36
  7. 2008, International Vocabulary of Metrology - Basic and general concepts and associated terms
  8. Heyries K. A., 2011, Nat. Methods, 8, 649, 10.1038/nmeth.1640 · DOI · Paper page
  9. Pekin D., 2011, Lab Chip, 11, 2156, 10.1039/c1lc20128j · DOI · Paper page
  10. Griffiths K. R., 2011, Anal. Methods, 3, 2201, 10.1039/c1ay05069a · DOI

Cited by

See all 1,055

Metadata

Authors
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R.
Venue
Analytical Chemistry
Published
2011-12-21
Volume
84
Issue
2
Pages
1003-1011
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2113559596
Cited by
1,055
References
5
FWCI
11.52
Type
journal article
Language
en
Open access
hybrid
Funders
National Institute of Biomedical Imaging and Bioengineering

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification. https://app.cochat.ai/papers/10.1021/ac202578x
The paper
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2012). Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification. Analytical Chemistry. https://doi.org/10.1021/ac202578x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.