Dielectrophoresis for manipulation of micro/nano particles in microfluidic systems
Open accessThe DOI matches its Crossref record; 112 of the 112 references it cites were found in a registry or an index.
Abstract
Dielectrophoretic (DEP) force is exerted when a neutral particle is polarized in a non-uniform electric field, and depends on the dielectric properties of the particle and the suspending medium. The integration of DEP and microfluidic systems offers numerous applications for the separation, trapping, assembling, transportation, and characterization of micro/nano particles. This article reviews the applications of DEP forces in microfluidic systems. It presents the theory of dielectrophoresis, different configurations, and the applications of such systems for particle manipulation and device fabrication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in the science and technology of carbon nanotubes and their composites: a review
Thostenson, E. T., Ren, Z., & Chou, T.-W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(01)00094-x · Cited by 5,005
Separation of Metallic from Semiconducting Single-Walled Carbon Nanotubes
Krupke, R., Hennrich, F., Löhneysen, H. V., & Kappes, M. M. (2003) · Science · doi:10.1126/science.1086534 · Cited by 1,552
Ac electrokinetics: a review of forces in microelectrode structures
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/18/021 · Cited by 1,233
Integrated optofluidics: A new river of light
Monat, C., Domachuk, P., & Eggleton, B. J. (2007) · Nature Photonics · doi:10.1038/nphoton.2006.96 · Cited by 955
Dielectrophoresis: The Behavior of Neutral Matter in Nonuniform Electric Fields
Pohl, H. A. (1978) · Medical Entomology and Zoology · Cited by 935
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862
Self-citationParticle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Nanoliter-scale synthesis of arrayed biomaterials and application to human embryonic stem cells
Anderson, D. G., Levenberg, S., & Langer, R. (2004) · Nature Biotechnology · doi:10.1038/nbt981 · Cited by 747
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Cited by
Electric field-induced chemical locomotion of conducting objects
Loget, G., & Kuhn, A. (2011) · Nature Communications · doi:10.1038/ncomms1550 · Cited by 475
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Li, M., Li, W. H., Zhang, J., Alici, G., & Wen, W. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/6/063001 · Cited by 223
“cells, viruses, bacteria, DNA and proteins) in microfluidic systems, which have been reviewed in the relevant literature [11,12,13,14,15,16,17,18].”
Microfluidics and Raman microscopy: current applications and future challenges
Chrimes, A. F., Khoshmanesh, K., Stoddart, P. R., Mitchell, A., & Kalantar-zadeh, K. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35515b · Cited by 217
Self-citationRare cell capture in microfluidic devices
Pratt, E. D., Huang, C., Hawkins, B. G., Gleghorn, J. P., & Kirby, B. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.09.012 · Cited by 194
“The scope of this review on DEP methods will be limited to those used for capture, separation, or concentration of bulk cell populations; DEP methods for single cell capture or manipulation are covered in other reviews (Voldman, 2006; Hawkins et al., 2009; Bao et al., 2008; Kang and Li, 2009; Zhang et al., 2010).”
MethodFan, X., Jia, C., Yang, J., Li, G., Mao, H., Jin, Q., & Zhao, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.04.080 · Cited by 179
Microfluidic devices for sample preparation and rapid detection of foodborne pathogens
Kant, K., Shahbazi, M.-A., Dave, V. P., Ngo, T. A., Chidambara, V. A., Than, L. Q., Bang, D. D., & Wolff, A. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.03.002 · Cited by 179
Recent Advances and Future Perspectives on Microfluidic Liquid Handling
Nguyen, N.-T., Hejazian, M., Ooi, C., & Kashaninejad, N. (2017) · Micromachines · doi:10.3390/mi8060186 · Cited by 175
Metadata
- Authors
- Zhang, C., Khoshmanesh, K., Mitchell, A., & Kalantar-zadeh, K.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2009-07-04
- Volume
- 396
- Issue
- 1
- Pages
- 401-420
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2069529110
- Cited by
- 305
- References
- 112
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.