Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Vitamin D is an important determinant of bone health at all ages. The plasma concentrations of 25-hydroxy vitamin D (25-OH D) and other metabolites are used as biomarkers for vitamin sufficiency and function. To allow for the simultaneous determination of five vitamin D metabolites, 25-OH D(3), 25-OH D(2), 24,25-(OH)(2) D(3), 1,25-(OH)(2) D(3), and 1,25-(OH)(2) D(2), in low volumes of human plasma, an assay using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was established. Plasma samples were spiked with isotope-labeled internal standards and pretreated using protein precipitation, solid-phase extraction (SPE) and a Diels-Alder derivatization step with 4-phenyl-1,2,4-triazoline-3,5-dione. The SPE recovery rates ranged from 55% to 85%, depending on the vitamin D metabolite; the total sample run time was <5 min. Mass spectrometry was conducted using positive ion electrospray ionization in the multiple reaction monitoring mode on a quadrupole-quadrupole-linear ion trap instrument after pre-column addition of methylamine to increase the ionization efficiency. The intra- and inter-day relative standard deviations were 1.6-4.1% and 3.7-6.8%, respectively. The limit of quantitation for these compounds was determined to be between 10 and 20 pg/mL. The 25-OH D results were compared with values obtained for reference materials (DEQAS). In addition, plasma samples were analyzed with two additional Diasorin antibody assays. All comparisons with conventional methods showed excellent correlations (r(2) = 0.9738) for DEQAS samples, demonstrating the high degree of comparability of the new UHPLC-MS/MS technique to existing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Norman, A. W. (1979) · Cited by 3,769
Dusso, A. S., Brown, A. J., & Slatopolsky, E. (2005) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00336.2004 · Cited by 1,148
Norman, A. W. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/88.2.491s · Cited by 1,090
Assay Variation Confounds the Diagnosis of Hypovitaminosis D: A Call for Standardization
Binkley, N., Krueger, D., Cowgill, C. S., Plum, L., Lake, E., Hansen, K. E., DeLuca, H. F., & Drezner, M. K. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031979 · Cited by 577
Maunsell, Z., Wright, D. J., & Rainbow, S. J. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.052936 · Cited by 382
Roth, H. J., Schmidt-Gayk, H., Weber, H., & Niederau, C. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2007.007091 · Cited by 309
Carter, G. D., Carter, R., Jones, J., & Berry, J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.040683 · Cited by 306
Tai, S. S.-C., Bedner, M., & Phinney, K. W. (2010) · Analytical Chemistry · doi:10.1021/ac9026862 · Cited by 271
Vitamin D across the lifecycle: physiology and biomarkers
Prentice, A., Goldberg, G. R., & Schoenmakers, I. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/88.2.500s · Cited by 258
Self-citationHPLC Method for 25-Hydroxyvitamin D Measurement: Comparison with Contemporary Assays
Lensmeyer, G. L., Wiebe, D. A., Binkley, N., & Drezner, M. K. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.064956 · Cited by 239
Cited by
Metabolite identification and quantitation in LC-MS/MS-based metabolomics
Xiao, J. F., Zhou, B., & Ressom, H. W. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.08.009 · Cited by 620
Jones, K. S., Assar, S., Harnpanich, D., Bouillon, R., Lambrechts, D., Prentice, A., & Schoenmakers, I. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-1714 · Cited by 276
Self-citationAssessment of vitamin D status – a changing landscape
Herrmann, M., Farrell, C.-J. L., Pusceddu, I., Fabregat-Cabello, N., & Cavalier, E. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0264 · Cited by 232
“The most common Cooksontype reagent is PTAD [171, 175–177, 179–194], but other similar reactants such as MBOTAD [187], DMEQ-TAD [188] or DAPTAD [168, 188, 190] have also been tested.”
BackgroundMethodInfluentialA new strategy for ionization enhancement by derivatization for mass spectrometry
Iwasaki, Y., Nakano, Y., Mochizuki, K., Nomoto, M., Takahashi, Y., Ito, R., Saito, K., & Nakazawa, H. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.02.008 · Cited by 113
Metadata
- Authors
- Ding, S., Schoenmakers, I., Jones, K., Koulman, A., Prentice, A., & Volmer, D. A.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2010-07-14
- Volume
- 398
- Issue
- 2
- Pages
- 779-789
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2042938856
- Cited by
- 161
- References
- 41
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.