Hydrophilic interaction liquid chromatography (HILIC)—a powerful separation technique
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Hydrophilic interaction liquid chromatography (HILIC) provides an alternative approach to effectively separate small polar compounds on polar stationary phases. The purpose of this work was to review the options for the characterization of HILIC stationary phases and their applications for separations of polar compounds in complex matrices. The characteristics of the hydrophilic stationary phase may affect and in some cases limit the choices of mobile phase composition, ion strength or buffer pH value available, since mechanisms other than hydrophilic partitioning could potentially occur. Enhancing our understanding of retention behavior in HILIC increases the scope of possible applications of liquid chromatography. One interesting option may also be to use HILIC in orthogonal and/or two-dimensional separations. Bioapplications of HILIC systems are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alpert, A. J. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)96972-3 · Cited by 1,966
Hydrophilic interaction chromatography
Hemström, P., & Irgum, K. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600199 · Cited by 1,176
Gradient elution in high-performance liquid chromatography
Snyder, L. R., Dolan, J. W., & Gant, J. R. (1979) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)85726-x · Cited by 848
Orthogonality of Separation in Two-Dimensional Liquid Chromatography
Gilar, M., Olivova, P., Daly, A. E., & Gebler, J. C. (2005) · Analytical Chemistry · doi:10.1021/ac050923i · Cited by 816
Quantitative structure—chromatographic retention relationships
(1988) · European Journal of Medicinal Chemistry · doi:10.1016/0223-5234(88)90180-8 · Cited by 641
Alpert, A. J. (2008) · Analytical Chemistry · doi:10.1021/ac070997p · Cited by 523
Guo, Y., & Gaiki, S. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.03.058 · Cited by 494
Tolstikov, V. V., & Fiehn, O. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5513 · Cited by 472
Hägglund, P., Bunkenborg, J., Elortza, F., Jensen, O. N., & Roepstorff, P. (2004) · Journal of Proteome Research · doi:10.1021/pr034112b · Cited by 460
QSRR: Quantitative Structure-(Chromatographic) Retention Relationships
Kaliszan, R. (2007) · Chemical Reviews · doi:10.1021/cr068412z · Cited by 460
Cited by
Expanding the medicinal chemistry synthetic toolbox
Boström, J., Brown, D. G., Young, R. J., & Keserü, G. M. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.116 · Cited by 665
Glycosylation: mechanisms, biological functions and clinical implications
He, M., Zhou, X., & Wang, X. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01886-1 · Cited by 499
Metabolite Measurement: Pitfalls to Avoid and Practices to Follow
Lu, W., Su, X., Klein, M. S., Lewis, I. A., Fiehn, O., & Rabinowitz, J. D. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061516-044952 · Cited by 462
Matrix Effects and Application of Matrix Effect Factor
Zhou, W., Yang, S., & Wang, P. G. (2017) · Bioanalysis · doi:10.4155/bio-2017-0214 · Cited by 430
Žuvela, P., Skoczylas, M., Jay Liu, J., Ba̧czek, T., Kaliszan, R., Wong, M. W., & Buszewski, B. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00246 · Cited by 354
Self-citationMass spectrometric based approaches in urine metabolomics and biomarker discovery
Khamis, M. M., Adamko, D. J., & El‐Aneed, A. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21455 · Cited by 342
Prasse, C., Stalter, D., Schulte-Oehlmann, U., Oehlmann, J., & Ternes, T. A. (2015) · Water Research · doi:10.1016/j.watres.2015.09.023 · Cited by 319
Jandera, P., & Janás, P. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.060 · Cited by 309
Masiá, A., Suarez-Varela, M. M., Llopis-Gonzalez, A., & Picó, Y. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.07.023 · Cited by 300
NORMAN guidance on suspect and non-target screening in environmental monitoring
Hollender, J., Schymanski, E. L., Ahrens, L., Alygizakis, N., Béen, F., Bijlsma, L., Brunner, A. M., Celma, A., Fildier, A., Fu, Q., et al. (2023) · Environmental Sciences Europe · doi:10.1186/s12302-023-00779-4 · Cited by 278
Ivanisevic, J., Zhu, Z.-J., Plate, L., Tautenhahn, R., Chen, S., O’Brien, P. J., Johnson, C. H., Marletta, M. A., Patti, G. J., & Siuzdak, G. (2013) · Analytical Chemistry · doi:10.1021/ac401140h · Cited by 264
Recent advances and perspectives of metabolomics-based investigations in Parkinson’s disease
Shao, Y., & Le, W. (2019) · Molecular Neurodegeneration · doi:10.1186/s13024-018-0304-2 · Cited by 238
“Reverse-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC) are two major chromatographic separation techniques [36], which provide complementary metabolic information [37].”
BackgroundRecent Trends in Nucleotide Synthesis
Roy, B., Depaix, A., Périgaud, C., & Peyrottes, S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00174 · Cited by 212
Current and future trends in UHPLC
Fekete, S., Schappler, J., Veuthey, J.-L., & Guillarme, D. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.08.007 · Cited by 195
Comprehensive Overview of Bottom-Up Proteomics Using Mass Spectrometry
Jiang, Y., Rex, D. A. B., Schuster, D., Neely, B. A., Rosano, G. L., Volkmar, N., Momenzadeh, A., Peters-Clarke, T. M., Egbert, S. B., Kreimer, S., et al. (2024) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.3c00068 · Cited by 190
Westereng, B., Agger, J. W., Horn, S. J., Vaaje-Kolstad, G., Aachmann, F. L., Stenstrøm, Y. H., & Eijsink, V. G. H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.11.048 · Cited by 176
Piovesana, S., Capriotti, A. L., Cavaliere, C., La Barbera, G., Montone, C. M., Zenezini Chiozzi, R., & Laganà, A. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-0852-x · Cited by 173
Analytical and Biochemical Perspectives of Protein O-GlcNAcylation
Ma, J., Wu, C., & Hart, G. W. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00884 · Cited by 169
Characterization of isomeric glycan structures by LC‐MS/MS
Veillon, L., Huang, Y., Peng, W., Dong, X., Cho, B. G., & Mechref, Y. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201700042 · Cited by 163
From Omics to Multi-Omics: A Review of Advantages and Tradeoffs
Hayes, C. N., Nakahara, H., Ono, A., Tsuge, M., & Oka, S. (2024) · Genes · doi:10.3390/genes15121551 · Cited by 119
Extraction of High-Value Chemicals from Plants for Technical and Medical Applications
Kapadia, P., Newell, A. S., Cunningham, J., Roberts, M. R., & Hardy, J. G. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms231810334 · Cited by 111
“RPLC is popular in the analysis of metabolomics [232,233], whilst HILC is used for polar molecules to increase the range of the compounds that may be investigated by LC [232,234], with IELC expanding the scope of LC-MS even further for the analysis of highly polar molecules [232,235].”
MethodParker, B. A., Knappe, D. R. U., Titaley, I. A., Wanzek, T. A., & Field, J. A. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.1c08345 · Cited by 32
Glazowska (2018) · doi:10.1002/jssc.201800506 · Cited by 22
Zhao, H., Zhang, M., Liu, Q., Wang, X., Zhao, R., Geng, Y., Wong, T., Li, S., & Wang, X. (2018) · Journal of Environmental Science and Health, Part C · doi:10.1080/10590501.2018.1450201 · Cited by 14
Metadata
- Authors
- Buszewski, B., & Noga, S.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2011-08-31
- Volume
- 402
- Issue
- 1
- Pages
- 231-247
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2015466408
- Cited by
- 1,235
- References
- 46
- FWCI
- 22.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.