Recent developments in dispersive liquid–liquid microextraction
The DOI matches its Crossref record; 238 of the 238 references it cites were found in a registry or an index.
Abstract
During the past 7 years and since the introduction of dispersive liquid-liquid microextraction (DLLME), the method has gained widespread acceptance as a simple, fast, and miniaturized sample preparation technique. Owing to its simplicity of operation, rapidity, low cost, high recovery, and low consumption of organic solvents and reagents, it has been applied for determination of a vast variety of organic and inorganic compounds in different matrices. This review summarizes the DLLME principles, historical developments, and various modes of the technique, recent trends, and selected applications. The main focus is on recent technological advances and important applications of DLLME. In this review, six important aspects in the development of DLLME are discussed: (1) the type of extraction solvent, (2) the type of disperser solvent, (3) combination of DLLME with other extraction methods, (4) automation of DLLME, (5) derivatization reactions in DLLME, and (6) the application of DLLME for metal analysis. Literature published from 2010 to April 2013 is covered.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The extraction solvent is dispersed in the aqueous sample by getting help from the disperser and consequently forms microdroplets of the extractant, inside the aqueous sample, which enables a very fast extraction process [102,103].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [103]
In the citing paper
“Some novel methods accelerate the process through carriermediated extraction or electrokinetic migration [103,165,166].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [103]
Citations
Cites
Anastassiades, M., Lehotay, S. J., Štajnbaher, D., & Schenck, F. J. (2003) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/86.2.412 · Cited by 5,670 · cited 1×
“The QuEChERS method is a well-known extraction technique for simultaneous analysis of a large number of pesticides in a variety of matrices [152].”
MethodSolid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997 · cited 2×
“M. Saraji (*) :M. K. Boroujeni Department of Chemistry, Isfahan University of Technology, Isfahan 84156-83111, Iran e-mail: saraji@cc.iut.ac.ir The introduction of solid-phase microextraction (SPME) by Arthur and Pawliszyn [1] in 1990 initiated the use of microextraction techniques in analytical chemistry.”
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · cited 4×
“The extraction recovery (R) is defined as the percentage of the total analyte amount (n 0) which is transferred to the extracted phase (nexd) [6]: R % ð Þ 1⁄4 nexd n0 100 1⁄4 CexdV exd C0V aq 100; where Vexd and Vaq are the volumes of the extracted phase and the sample solution, respectively.”
InfluentialSolvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282 · cited 6×
“In the SDME technique, a microdrop of solvent is suspended from the tip of a microsyringe.”
InfluentialPedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245 · cited 3×
“In LPME, only a small amount of solvent (microliter volume) is needed for the concentration of analytes from aqueous samples.”
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971 · cited 10×
“The technique has low selectivity and sample cleanup efficiency, so different types of water samples (tap water, river water, well water, seawater, and lake water) constitute the matrix most commonly studied [7–18].”
BackgroundInfluentialBerijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870 · cited 3×
“The technique has low selectivity and sample cleanup efficiency, so different types of water samples (tap water, river water, well water, seawater, and lake water) constitute the matrix most commonly studied [7–18].”
BackgroundJeannot, M. A., & Cantwell, F. F. (1997) · Analytical Chemistry · doi:10.1021/ac960814r · Cited by 558 · cited 6×
“In the SDME technique, a microdrop of solvent is suspended from the tip of a microsyringe.”
InfluentialRegueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547 · cited 1×
“[124].”
Dispersive liquid-liquid microextraction
Zgoła-Grześkowiak, A., & Grześkowiak, T. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.014 · Cited by 476 · cited 7×
“The technique has low selectivity and sample cleanup efficiency, so different types of water samples (tap water, river water, well water, seawater, and lake water) constitute the matrix most commonly studied [7–18].”
BackgroundInfluential
Cited by
Items 101–200 of 230
Alcantara, G. K. S., Calixto, L. A., Rocha, B. A., Barbosa, F., de Oliveira, A. R. M., & de Gaitani, C. M. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104894 · Cited by 21
Mirmoghaddam, M., Kaykhaii, M., & Yahyavi, H. (2015) · Analytical Methods · doi:10.1039/c5ay01970b · Cited by 19
Dispersive liquid-liquid microextraction for a rapid determination of glyoxal in alcoholic beverages
Rodríguez‐Cáceres, M. I., Palomino‐Vasco, M., Mora-Díez, N. M., & Acedo-Valenzuela, M. I. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.031 · Cited by 19
Javadi, T., Farajmand, B., Yaftian, M. R., & Zamani, A. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.460733 · Cited by 21
Tolcha, T., Gemechu, T., Al‐Hamimi, S., Megersa, N., & Turner, C. (2020) · Molecules · doi:10.3390/molecules25041012 · Cited by 20
Bahadır, Z., Bulut, V. N., Bektaş, H., & Soylak, M. (2016) · RSC Advances · doi:10.1039/c5ra26575d · Cited by 19
Jalili, V., Kakavandi, M. G., Ghiasvand, A., & Barkhordari, A. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.107442 · Cited by 18
Microextractions in forensic toxicology: The potential role of ionic liquids
Boeck, M. D., Dehaen, W., Tytgat, J., & Cuypers, E. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.036 · Cited by 18
Dispersive Liquid–Liquid Microextraction of Pesticides Using Ionic Liquids As Extractants
Бессонова, Е. А., Deev, V., & Kartsova, L. A. (2020) · Journal of Analytical Chemistry · doi:10.1134/s1061934820080043 · Cited by 17
Maneeboon, T., Chuaysrinule, C., & Mahakarnchanakul, W. (2023) · Toxins · doi:10.3390/toxins15040277 · Cited by 16
“After centrifugation, the enriched analyte in the organic layer is determined based on suitable analytical techniques [22].”
MethodBoeck, M. D., Dehaen, W., Tytgat, J., & Cuypers, E. (2018) · Journal of Forensic Sciences · doi:10.1111/1556-4029.13778 · Cited by 18
“factors and more environmentally friendly procedures (1,4,5).”
Jayasinghe, G. D. T. M., Domínguez‐González, R., Bermejo‐Barrera, P., & Moreda‐Piñeiro, A. (2020) · Journal of Separation Science · doi:10.1002/jssc.201901129 · Cited by 16
Razavi, N., Foroutan, F., Sahebian, S., & Khaki, J. V. (2022) · Biomedical Chromatography · doi:10.1002/bmc.5547 · Cited by 18
Etana, E., & Mekassa, B. (2024) · Chinese Journal of Analytical Chemistry · doi:10.1016/j.cjac.2024.100458 · Cited by 16
Khiat, M., Pacheco‐Fernández, I., Pino, V., Benabdallah, T., Ayala, J. H., & Afonso, A. M. (2018) · Analytical Methods · doi:10.1039/c8ay00022k · Cited by 18
Ramin, M., Khadem, M., Omidi, F., Pourhossein, M., Golbabaei, F., & Shahtaheri, S. J. (2020) · Iranian Journal of Public Health · doi:10.18502/ijph.v48i10.3498 · Cited by 18
“cholinesterase activity that causes neural impulse transmission prevention (4-6).”
BackgroundCai, P., Xiong, X., Li, D., Zhou, Y., & Xiong, C. (2019) · Bioanalysis · doi:10.4155/bio-2019-0171 · Cited by 15
Silva, A. B., de Sá, Í. P., Higuera, J. M., & Nogueira, A. R. A. (2020) · Food Analytical Methods · doi:10.1007/s12161-020-01898-x · Cited by 15
“Thus, it also follows the green chemistry principles (Saraji and Boroujeni 2014; Mousavi et al. 2018).”
BackgroundCerdà, V., Ferreira, S. L. C., & Phansi, P. (2022) · Molecules · doi:10.3390/molecules27217279 · Cited by 15
“The Dispersive Liquid-Liquid Microextraction (DLLME) technique [1] was developed by Rezaee et al.”
MethodIonic liquids and deep eutectic solvents in wastewater treatment: recent endeavours
Sarkar, A., & Pandey, S. (2024) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-023-04865-1 · Cited by 14
Nedaei, M., Abdi, K., Ghorbanian, S. A., & Pirooznia, N. (2020) · Chromatographia · doi:10.1007/s10337-020-03952-6 · Cited by 14
Özcan, R., Büyükpınar, Ç., & Bakırdere, S. (2020) · Journal of Environmental Science and Health Part B · doi:10.1080/03601234.2020.1808417 · Cited by 15
Bordagaray, A., Millán, E., & García-Arrona, R. (2016) · Journal of Food Chemistry and Nanotechnology · doi:10.17756/jfcn.2016-021 · Cited by 13
“Moreover, to couple SPME to chromatographic system an interface is needed, especially in HPLC case, whereas with LPME usually the extractant is directly injected with a common syringe [31, 35, 71, 73, 85].”
MethodLorenzetti, A. S., Domini, C. E., & Lista, A. G. (2017) · Food Chemistry · doi:10.1016/j.foodchem.2017.05.132 · Cited by 14
Ferreira, V. J., Virgens, F. B. S., Pires, L. N., Dias, F. D. S., Lemos, V. A., & Teixeira, L. S. G. (2022) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2022.2113537 · Cited by 12
“[60,63] This technique has the advantage of being an efficient, fast, low-cost separation and preconcentration technique.”
MethodGéhin, C., O'Neill, N., Moore, A., Harrison, M. W., Holman, S. W., & Blom, G. (2023) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2023.03.016 · Cited by 16
Alami, F. M., Mousavi, H. Z., & Khaligh, A. (2018) · Food Analytical Methods · doi:10.1007/s12161-018-1196-z · Cited by 13
“2008) have been introduced to improve its efficiency and eliminate the disperser solvent (Asfaram & Ghaedi. 2016; Asfaram et al. 2015; Ghazaghi et al. 2016; Saraji and Boroujeni, 2014; Shirkhanloo et al. 2017).”
BackgroundSkok, A., Bazeľ, Y., & Vishnikin, A. B. (2022) · Journal of Sulfur Chemistry · doi:10.1080/17415993.2022.2045294 · Cited by 15
“In contrast to SPME,DLLME is less prone to analyte losses [116].”
BackgroundPocurull, E., Fontanals, N., Calull, M., & Aguilar, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816911-7.00020-7 · Cited by 16
Introduction to Green Sample Preparation
Canpolat, G., Dolak, İ., Hussain, C. G., Keçili, R., & Hussain, C. M. (2023) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781839166419-00001 · Cited by 14
Gao, M. J., Zhang, X., Ma, S., Wang, J., Mammah, M., Du, L., & Wang, X. (2022) · Analytical Methods · doi:10.1039/d1ay01698a · Cited by 13
Šulc, J., Pacheco‐Fernández, I., Ayala, J. H., Bajerová, P., & Pino, V. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462219 · Cited by 11
Alqarni, A. M., Mostafa, A., Shaaban, H., Mokhtar, H. I., Aseeri, A., Alkarshami, B., Alonaizi, S. M., Alrafidi, R. D., Aseeri, A. A., & Alrofaidi, M. A. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110244 · Cited by 11
Fathi, A. A., Mogaddam, M. R. A., Sorouraddin, S. M., & Farajzadeh, M. A. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.465478 · Cited by 10
Przyjazny, A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.12678-2 · Cited by 13
Dahaghin, Z., Mousavi, H. Z., Mirparizi, E., & Haghighat, P. (2018) · Chemical Papers · doi:10.1007/s11696-018-0387-9 · Cited by 10
“Magnetic Fe3O4 nanoparticles (MNPs) were obtained based on simple chemical coprecipitation of Fe2+ and Fe3+ ions as reported elsewhere (Saraji and Boroujeni 2014).”
MethodSaraji, M., Jamshidi, F., Mossaddegh, M., & Farajmand, B. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.02.030 · Cited by 10
Self-citationThe Advancement of Analytical Techniques in Drug Development and Validation
Haque, S. M., Kabir, A., Abu-Thabit, N. Y., Kachhawaha, A. S., Prajapati, P., Sreekumar, P. A., & Siddiqui, M. R. (2026) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2610318 · Cited by 12
Zhao, L., Weirui, C., Xue, X., Wang, M., Wu, L., & Yu, L. (2017) · Journal of Separation Science · doi:10.1002/jssc.201601257 · Cited by 11
“The extraction time with vortex mixing has been proposed to increase interfacial tension of the extraction solvent and contribute to higher analyte recovery [28].”
BackgroundDeep eutectic solvents for the determination of endocrine disrupting chemicals
Chormey, D. S., Zaman, B. T., Borahan, T., Erarpat, S., Bodur, S., Er, E. Ö., & Bakırdere, S. (2023) · Talanta · doi:10.1016/j.talanta.2023.125340 · Cited by 9
Khoshmaram, L., & Bagherian, E. (2023) · Analytical Methods · doi:10.1039/d3ay01698f · Cited by 9
Sirén, H. M. M., Tavaststjerna, T., & Riekkola, M. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462233 · Cited by 9
Beshana, S., Hussen, A., Leta, S., & Kaneta, T. (2022) · Analytical Sciences · doi:10.1007/s44211-022-00167-7 · Cited by 10
Porfírio, S., Sonon, R. N., da Silva, M. G., Peixe, A., Cabrita, M. J., & Azadi, P. (2016) · Analytical Methods · doi:10.1039/c6ay01289b · Cited by 10
Jaberi, M., Hashemi, P., & Rahimi, A. (2023) · Food Analytical Methods · doi:10.1007/s12161-023-02531-3 · Cited by 8
“The DLLME applications are mostly concentrated on simple water samples (Leong et al. 2014; Rezaee et al. 1 3 2010; Rykowska et al. 2018; Saraji and Boroujeni 2014; Zgoła-Grześkowiak and Grześkowiak 2011).”
BackgroundJusto-Vega, A., Domínguez‐González, R., Bermejo‐Barrera, P., & Moreda‐Piñeiro, A. (2024) · Journal of Analytical Atomic Spectrometry · doi:10.1039/d3ja00227f · Cited by 9
Towards metals analysis using corona discharge ionization ion mobility spectrometry
Jafari, M. T., Saraji, M., & Sherafatmand, H. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.12.036 · Cited by 8
Self-citationBocato, M. Z., Moreira, F. D. L., de Albuquerque, N. C. P., de Gaitani, C. M., & de Oliveira, A. R. M. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.06.028 · Cited by 8
Tolcha, T., & Megersa, N. (2018) · American Journal of Analytical Chemistry · doi:10.4236/ajac.2018.94018 · Cited by 9
“Due to their occurrence at trace levels and the complexity of environmental samples, analysis of pesticide residues requires selective and efficient sample preparation methods that enable simultaneous extraction and preconcentration, prior to their instrumental determination [15] [16] [17] [18].”
BackgroundSafaei, S., Atazadeh, R., & Mogaddam, M. R. A. (2022) · Journal of Separation Science · doi:10.1002/jssc.202200236 · Cited by 8
Sample preparation for liquid chromatography
Kataoka, H. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99969-4.00006-1 · Cited by 13
ISLAMI-BONAB, F., Sajedi‐Amin, S., Sorouraddin, S. M., Maleknia, S. D., & Naseri, A. (2021) · TURKISH JOURNAL OF CHEMISTRY · doi:10.3906/kim-2010-24 · Cited by 9
“The main drawback of LLME is due to the use of chlorinated solvents [18,19].”
A tutorial on developing metric tools for sample preparation: from green towards sustainable
Sanjuan-Navarro, L., Benedé, J. L., Rubio, S., Moreno, C., Pino, V., Pena‐Pereira, F., & Moliner-Martínez, Y. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.345044 · Cited by 10
Martin, P. R., Büchner, D., Jochmann, M. A., & Haderlein, S. B. (2024) · Analytical Methods · doi:10.1039/d3ay01981k · Cited by 7
Chen, M., Shi, L., Xie, F., Wang, X., Cong, N., Wang, S., Liu, K., Yu, J., & Wan, L. (2025) · Journal of Chromatography A · doi:10.1016/j.chroma.2025.465659 · Cited by 7
Gonzalez‐Siso, P., Lorenzo, R. A., Regenjo, M., Fernández, P., & Carro, A. M. (2015) · Journal of Separation Science · doi:10.1002/jssc.201500468 · Cited by 8
Greening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6
Elbakri, A. M., Mortada, W. I., El-Defrawy, M. M., & Eltabey, R. M. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.117550 · Cited by 9
Diab, M. A., El‐Sabban, H. A., & Baek, K.-H. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.112182 · Cited by 6
Bombana, H. S., Meirelles, G. D. P., de Oliveira, R. A., Leyton, V., & Yonamine, M. (2025) · Journal of Analytical Toxicology · doi:10.1093/jat/bkaf027 · Cited by 6
Saraji, M., & Ghambari, H. (2018) · Journal of Separation Science · doi:10.1002/jssc.201800133 · Cited by 7
Self-citationParente, C., Torgan, N., Calixto, L. A., Lemos, S. G., de Moraes, M. D. L. L., Carrilho, E. N. V. M., & Labuto, G. (2022) · Sustainable Chemistry and Pharmacy · doi:10.1016/j.scp.2022.100669 · Cited by 8
Microextraction Techniques in LC‐MS Bioanalysis
Rodrigues, M., Fortuna, A., Falcão, A., & Alves, G. (2019) · Sample Preparation in LC‐MS Bioanalysis · doi:10.1002/9781119274315.ch8 · Cited by 5
Shahin, R. Y., Noureldeen, D. A. M., Taha, H. M. G., & Attia, T. Z. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.115263 · Cited by 5
Akawa, M. N., Dimpe, K. M., & Nomngongo, P. N. (2022) · Journal of Analytical Science & Technology · doi:10.1186/s40543-022-00361-2 · Cited by 5
A Review on Pretreatment and Analysis Methods of Polyether Antibiotics in Complex Samples
Wei, X., Zhang, Y., Zhou, Y., Li, M., Liu, Z., Feng, X., & Tan, Y. (2023) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2023.2251156 · Cited by 5
“[108] Supramolecular solvent (SUPRAS) is the extraction solvent which is a kind of micellar aggregate with a nanostructure formed by amphiphilic compounds through intermolecular ordered self-assembly.”
Saeedi, Z., Lotfi, A., Hassanzadeh, J., & Bagheri, N. (2017) · Canadian Journal of Chemistry · doi:10.1139/cjc-2016-0558 · Cited by 6
Zheng, Y., Liu, Y., Zhang, Z., Hua, L., Fang, J., Wang, L., & Zhao, H. (2024) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.9684 · Cited by 5
New methodologies and equipment used in new-generation separation and preconcentration methods
Azqhandi, M. H. A., Khezeli, T., Ghaedi, M., & Daneshfar, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818569-8.00004-8 · Cited by 6
Trends in Multiresidue Analysis
Hernández‐Mesa, M., Lara, F. J. S., Moreno‐González, D., del Olmo‐Iruela, M., & García-Campaña, A. M. (2020) · Wiley eBooks · doi:10.1002/9780470027318.a9520.pub2 · Cited by 6
Advancements and innovations in solvent-based extraction techniques
Lanjwani, M. F., Khuhawar, M. Y., Tüzen, M., Fesliyan, S., & Altunay, N. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-16122-3.00009-3 · Cited by 6
Zaid, A., Zulkurnain, M., Patar, A., Raja, P. B., Kangiwa, A. I., Mohammed, M. I., Marriott, P. J., & Wong, Y. F. (2025) · Food Chemistry · doi:10.1016/j.foodchem.2025.145307 · Cited by 5
Farajzadeh, M. A., Fathipour, Z., Aghdam, M. B., & Mogaddam, M. R. A. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.109363 · Cited by 4
Sadi, B. B. M., Lee, J. Y., & Chen, J. (2016) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-016-4833-2 · Cited by 5
Microextraction and Solventless Techniques
Majedi, S. M., & Lee, H. K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-805297-6.00014-0 · Cited by 6
Xue, J., Zhang, D., Wu, X., Pan, D., & Hua, R. (2018) · Chromatographia · doi:10.1007/s10337-018-3678-y · Cited by 4
Determination of Volatile Organic Compounds: Enrichment and Analysis
Buszewski, B., Ligor, T., & Ulanowska, A. (2015) · Springer eBooks · doi:10.1007/978-3-319-19614-5_14 · Cited by 4
Trends in Multiresidue Analysis
Moreno‐González, D., Lara, F. J. S., del Olmo‐Iruela, M., & García-Campaña, A. M. (2015) · Wiley eBooks · doi:10.1002/9780470027318.a9520 · Cited by 10
Yang, J., He, Y., Du, C., Zuo, Y., Xie, L., Yan, P., Dong, R., Tu, X., & Chen, W. (2025) · Environmental Pollution · doi:10.1016/j.envpol.2025.127271 · Cited by 4
Verding, P., Heyden, Y. V., Eeckhaut, A. V., & Mangelings, D. (2025) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2025.117202 · Cited by 4
Sahebian, S., Razavi, N., Foroutan, F., & Khaki, J. V. (2022) · Research Square · doi:10.21203/rs.3.rs-1337548/v1 · Cited by 3
Shahin, R. Y., Attia, T. Z., Taha, H. M. G., & Mokhtar, D. A. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.116866 · Cited by 3
A review of pretreatment and analytical methods for triphenylmethane dyes in environmental samples
Wei, Y., Zhang, Y., Zhang, Y.-P., Liu, C., Shao, Y.-X., Zhai, Y., Wang, X., & Feng, X. (2026) · Journal of Chromatography A · doi:10.1016/j.chroma.2026.466901 · Cited by 3
Diuretics in Different Samples: Update on the Pretreatment and Analysis Techniques
Liu, Y., Bian, Y., Zhang, Y., Zhang, Y.-X., Ren, A., Lin, S., Feng, X., & Zhang, X. (2023) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2023.2202260 · Cited by 3
“[54] Han et al. [55] used DLLME to extract ethacrynic acid and FUR from human urine.”
Kavaliauskas, V., Olšauskaitė, V., & Padarauskas, A. (2022) · Chromatographia · doi:10.1007/s10337-022-04129-z · Cited by 2
“HPLC in reversed-phase mode (RP-HPLC) is the most common analytical technique used in combination with DLLME sample pretreatment procedures [5, 6, 16].”
BackgroundMethodDispersive liquid-liquid microextraction
Saraji, M., Shahvar, A., & Mansourzadeh, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00084-9 · Cited by 2
Self-citationNagler, J., Schriever, S. C., Romanov, A., Weisenhorn, D. M. V., Wurst, W., Pfluger, P. T., & Schramm, K. (2021) · Neurochemistry International · doi:10.1016/j.neuint.2021.105174 · Cited by 1
Fat-soluble vitamins (A, E, D, and K)
Nebot, C., Cardelle‐Cobas, A., Cepeda, A., & Vázquez, B. I. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823371-9.00005-8 · Cited by 1
Role of nanomaterials in the sample preparation step
Afkhami, A., Madrakian, T., & Ahmadi, M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-91741-4.00001-4 · Cited by 1
Pinheiro, J. F., Silva, L. K., Fonseca, N. D. N., Sousa, É. M. L., Lima, D. L. D., de Sousa, E. R., & da Silva, G. S. (2024) · Water and Environment Journal · doi:10.1111/wej.12961 · Cited by 1
“Pareto's charts show that the lower level favours increased response, which may be caused by the reduction of solubility of the extracting solvent in the aqueous sample, which affects the increase of the extracting phase volume and thus a decrease in the enrichment factor (Saraji & Boroujeni, 2014).”
Ahmadov, I. A. (2020) · Asian Journal of Chemistry · doi:10.14233/ajchem.2020.22863 · Cited by 1
Costa, L. F., da Silva, G. S., Freitas, A. S., da Silva, G. S., & de Sousa, E. R. (2020) · Revista Virtual de Química · doi:10.21577/1984-6835.20200054 · Cited by 2
Zarei, A. R., & Mardi, K. (2022) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-022-02527-6 · Cited by 1
Zarei, A. R., & Mardi, K. (2022) · International Journal of Energetic Materials and Chemical Propulsion · doi:10.1615/intjenergeticmaterialschemprop.2022041581 · Cited by 1
Hanapi, N. S. M., Amraa, S. A., Anis, A. L., Zaini, N., Ibrahim, W. N. W., & Bonnia, N. N. (2022) · Trends in Sciences · doi:10.48048/tis.2022.6232 · Cited by 1
“This method has proven to be an efficient method due to the several advantages: Simple, low cost, high enrichment factor, high recovery factors, and rapidity [17].”
MethodRobaina, N. F., Cruz, G., & Cassella, R. J. (2023) · Journal of the Brazilian Chemical Society · doi:10.21577/0103-5053.20230007 · Cited by 1
Alemayehu, Y., Tolcha, T., & Megersa, N. (2022) · SINET Ethiopian Journal of Science · doi:10.4314/sinet.v45i3.2 · Cited by 1
Green miniaturized technologies based sample preparation techniques
Parmar, A., Jain, B., Jain, R., Sachar, S., Saini, A., & Sharma, S. (2024) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2023.08.004 · Cited by 1
Chormey, D. S., Bodur, S. E., Er, E. Ö., Zaman, B. T., Bodur, S., Şaylan, M., Bozyiğit, G. D., Serbest, H., & Bakırdere, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00077-1 · Cited by 2
Salami, O. S., Sihlahla, M., Dladla, B. S., & Mketo, N. (2025) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2025.104991 · Cited by 2
Metadata
- Authors
- Saraji, M., & Boroujeni, M. K.
- Affiliations
- Isfahan University of Technology (IR)
- Corresponding author
- Saraji, Mohammad
- ORCID
- Saraji, Mohammad
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2013-11-21
- Volume
- 406
- Issue
- 8
- Pages
- 2027-2066
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2043435526
- Cited by
- 232
- References
- 238
- Citations by year
- 2026: 15 · 2025: 10 · 2024: 14 · 2023: 21 · 2022: 23 · 2021: 13 · 2020: 26 · 2019: 15 · 2018: 25 · 2017: 18 · 2016: 26 · 2015: 19 · 2014: 7
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Isfahan University of Technology
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- dispersive liquid-liquid microextraction, sample preparation, extraction solvents, derivatization, metal analysis, miniaturized sample preparation
- MeSH terms
- Animals, Food Analysis, Humans, Plasma, Urine, Water Pollutants, Chemical, Liquid Phase Microextraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.