Cited by 69Muscle activation and electromyography studiesMotor Control and AdaptationMuscle Physiology and Disorders

Variability of quadriceps femoris motor neuron discharge and muscle force in human aging

Welsh, Seth J., Dinenno, Devin V., Tracy, Brian L.·2007·Experimental Brain Research

Abstract

The purpose was to determine the contribution of visual feedback and the effect of aging on the variability of knee extensor (KE) muscle force and motor unit (MU) discharge. Single MUs were recorded during two types of isometric trials, (1) visual feedback provided (VIS) and then removed (NOVIS) during the trial (34 MUs from young, 32 from elderly), and (2) only NOVIS (66 MUs from young, 77 from elderly) during the trial. Recruitment threshold (RT) ranged from 0-37% MVC. Standard deviation (SD) and coefficient of variation (CV) of muscle force and MU interspike interval (ISI) was measured during steady contractions at target forces ranging from 0.3 to 54% MVC. Force drift (<0.5 Hz) was removed before analysis. VIS/NOVIS trials: the decrease in the CV of ISI from VIS to NOVIS was greater for MUs from elderly (12.5 +/- 4.1 to 9.94 +/- 2.6%) than young (10.6 +/- 3.3 to 10.3 +/- 2.8%, age group x vision interaction, P = 0.006). The change in CV of force from VIS to NOVIS was significantly greater for elderly (1.45 to 1.05%) than young (1.42 to 1.41%). NOVIS only trials: for all MUs, the average RT (6.6 +/- 7.7 % MVC), target force above RT (1.20 +/- 2.7% MVC), SD of ISI (0.012 +/- 0.005 s), and CV of ISI (11.1 +/- 3.3%) were similar for young and elderly MUs. The CV of force was similar between age groups for trials between 0 and 3% MVC (1.74 +/- 0.74%) and was greater for young subjects from 3 to 10% MVC (1.47 +/- 0.5 vs. 1.21 +/- 0.4%) and >10% MVC (1.44 +/- 0.6 vs. 1.01 +/- 0.3%). The CV of ISI was similar between age groups for MUs in 0-3, 3-10, and >10% bins of RT. Thus, the contribution of visuomotor correction to the variability of motor unit discharge and force is greater for elderly adults. The presence of visual feedback appears to be necessary to find greater discharge variability in motor units from the knee extensors of elderly adults.

Integrity signals

Registry

Crossref · 10.1007/s00221-006-0785-z

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Discharges with interdischarge intervals < 33.3 or >250 ms were excluded because firing rates calculated from this range are unusually high (>30 Hz) or low (<4 Hz) for the VL muscle.

    “We excluded the discharges with interdischarge intervals < 33.3 or >250 ms because firing rates that calculated from this range of interdischarge intervals are unusually high (>30 Hz) or low (<4 Hz) for the VL muscle (7,20,21,30,31).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Welsh, S. J., Dinenno, D. V., & Tracy, B. L.
Affiliations
Colorado State University (US)
Corresponding author
Tracy, Brian L.
Venue
Experimental Brain Research
Published
2006-11-30
Volume
179
Issue
2
Pages
219-233
ISSN
  • 0014-4819 (ISSN-L)
  • 1432-1106
OpenAlex
W2161536851
Cited by
69
References
56
Citations by year
2026: 1 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 4 · 2019: 2 · 2018: 7 · 2017: 4 · 2016: 4 · 2015: 4 · 2014: 3 · 2013: 3 · 2012: 4
FWCI
2.30
Type
journal article
Language
en
Open access
closed
Locations
  • Experimental Brain Research (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health
  • National Institute on Aging (K01AG019171, K01 AG19171)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
Keywords
aging, visual feedback, knee extensors, motor unit recruitment threshold, coefficient of variation, isometric contraction
MeSH terms
Action Potentials, Adolescent, Adult, Aged, Aging, Feedback, Female, Humans, Knee, Male, Motor Neurons, Muscle Contraction, Psychomotor Performance, Recruitment, Neurophysiological, Muscle, Skeletal, Muscle Fibers, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review