Functional properties of low-threshold mechanoreceptive afferents in the human labial mucosa
Abstract
We used microneurography to investigate the functional properties of low-threshold mechanoreceptive afferents innervating the oral mucosa of the inside of the lower lip. Impulse responses were recorded from the inferior alveolar nerve of four human subjects. The threshold force and receptive field boundaries were identified for 19 single mechanoreceptive afferents using thin filaments (von Frey hairs) that applied known forces to the mucosa. Most of the receptive fields were located close to the corners of the mouth. Twelve of the afferents were slowly adapting (SA) and the remaining seven units were fast adapting (FA). Two types of slowly adapting responses were observed, SA I and SA II. Four of the six SA II units were spontaneously active. The geometric mean value of the receptive field sizes was 4.20 mm(2) for the SA I units, 5.65 mm(2) for the SA II units, and 5.60 mm(2) for the FA I units. None of the FA afferents showed response properties characteristic of Pacinian-corpuscle type afferents (FA II units). All afferents showed low force threshold between 0.06 and 1 mN. The properties of the mechanoreceptors supplying the human labial mucosa appear more similar to those of the vermilion and facial skin of the lower lip than those supplying the mucosa of the dorsal tongue.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The size of receptive fields in facial skin has mean values of 4 mm2 for SAI, 6 mm2 for SAII, and 6 mm2 for FA fibers.
“The size of the receptive fields varies for the different tactile afferent fibers with a mean value of 4 mm 2 for the SAI fibers, 6 mm 2 for SAII fibers, and 6 mm 2 for FA fibers (Bukowska et al. 2010).”
From Tactile innervation densities across the whole body (2020) · cites this paper as Bukowska et al. 2010
Slowly adapting afferents appear more abundant than fast-adapting ones in facial skin, with around 65% SA resulting in 29,000 fibers and 35% FA resulting in 15,500 fibers.
“Slowly adapting afferents appear more abundant than fastadapting ones in the facial skin (Bukowska et al. 2010;Johansson et al. 1988), with around 65% SA, resulting in 29,000 fibers, and 35% FA, resulting in 15,500 fibers.”
From Tactile innervation densities across the whole body (2020) · cites this paper as Bukowska et al. 2010
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507 · see citing works
Mechanoreceptor activity from the human face and oral mucosa
Johansson, R. S., Trulsson, M., Olsson, K. Å., & Westberg, K. G. (1988) · Experimental Brain Research · doi:10.1007/bf00248518 · Cited by 256 · see citing works
Self-citationMechanical frequency detection thresholds in the human face
Barlow, S. M. (1987) · Experimental Neurology · doi:10.1016/0014-4886(87)90044-6 · Cited by 94 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Tactile innervation densities across the whole body
Corniani, G., & Saal, H. P. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00313.2020 · Cited by 396 · see citing works
- Authors
- Bukowska, M., Essick, G. K., & Trulsson, M.
- Affiliations
- Karolinska Institutet (SE)
- University of North Carolina at Chapel Hill (US)
- Corresponding author
- Trulsson, Mats
- Venue
- Experimental Brain Research
- Published
- 2009-09-22
- Volume
- 201
- Issue
- 1
- Pages
- 59-64
- ISSN
- 0014-4819 (ISSN-L)
- 1432-1106
- OpenAlex
- W2073311721
- Cited by
- 31
- References
- 3
- Citations by year
- 2023: 1 · 2022: 6 · 2021: 1 · 2020: 3 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 3 · 2012: 3
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Experimental Brain Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Karolinska Institutet
- Vetenskapsrådet
- Medical Research Council
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Neuroscience › Sensory Systems › Ion Channels and Receptors
- Health Sciences › Medicine › Physiology › Pain Mechanisms and Treatments
- Keywords
- low-threshold mechanoreceptors, labial mucosa, lower lip, oral mucosa, receptive field size, force threshold, slowly adapting afferents, spontaneous activity, Pacinian corpuscles, von Frey hairs, inferior alveolar nerve, microneurography
- MeSH terms
- Action Potentials, Afferent Pathways, Electrophysiology, Female, Humans, Lip, Mandibular Nerve, Mechanoreceptors, Mouth Mucosa, Pacinian Corpuscles, Physical Stimulation, Proprioception, Sensory Receptor Cells, Sensory Thresholds, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review