Analysis of Plasma Membrane Integrity by Fluorescent Detection of Tl+ Uptake
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
The exclusion of polar dyes by healthy cells is widely employed as a simple and reliable test for cell membrane integrity. However, commonly used dyes (propidium, Yo-Pro-1, trypan blue) cannot detect membrane defects which are smaller than the dye molecule itself, such as nanopores that form by exposure to ultrashort electric pulses (USEPs). Instead, here we demonstrate that opening of nanopores can be efficiently detected and studied by fluorescent measurement of Tl+ uptake. Various mammalian cells (CHO, GH3, NG108), loaded with a Tl+-sensitive fluorophore FluxOR™ and subjected to USEPs in a Tl+-containing bath buffer, displayed an immediate (within <100 ms), dose-dependent surge of fluorescence. In all tested cell lines, the threshold for membrane permeabilization to Tl+ by 600-ns USEP was at 1–2 kV/cm, and the rate of Tl+ uptake increased linearly with increasing the electric field. The lack of concurrent entry of larger dye molecules suggested that the size of nanopores is less than 1–1.5 nm. Tested ion channel inhibitors as well as removal of the extracellular Ca2+ did not block the USEP effect. Addition of a Tl+-containing buffer within less than 10 min after USEP also caused a fluorescence surge, which confirms the minutes-long lifetime of nanopores. Overall, the technique of fluorescent detection of Tl+ uptake proved highly effective, noninvasive and sensitive for visualization and analysis of membrane defects which are too small for conventional dye uptake detection methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ionic channels of excitable membranes
(1985) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(85)90172-7 · Cited by 6,982
Proteins: Structures and Molecular Properties
Creighton, T. E. (1986) · Medical Entomology and Zoology · Cited by 2,645
Ionic Channels of Excitable Membranes
Keynes, R. D. (1985) · Trends in Neurosciences · doi:10.1016/0166-2236(85)90088-8 · Cited by 2,590
Proteins. Structures and molecular properties
(1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90583-9 · Cited by 1,301 · cited 1×
“Gray areas show van der Waals surface of impenetrable molecular volume (Creighton 1993).”
Electroporation and Electrofusion in Cell Biology
(1989) · Springer eBooks · doi:10.1007/978-1-4899-2528-2 · Cited by 942 · cited 3×
“These dyes also proved extremely valuable for analysis and understanding of membrane disruption and resealing after electroporation (Djuzenova et al. 1996; Golzio et al. 2002; Neumann et al. 1989; Tekle et al. 1994; Weaver 2000; Zimmermann et al. 2000).”
Volkov, A. G., Paula, S., & Deamer, D. W. (1997) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(96)05097-0 · Cited by 661 · cited 1×
“Moreover, nanopores may open in lipid bilayers ‘‘spontaneously,’’ without application of an external field (Volkov et al. 1997).”
Teissie, J., Golzio, M., & Rols, M. P. (2005) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2005.05.006 · Cited by 622 · cited 1×
“Although the formation of aqueous pores by accumulation of charges at the plasma membrane, followed by membrane breakdown, is the most widely accepted mechanism, it does not adequately explain all experimental findings (Teissie et al. 2005).”
Reversible electrical breakdown of lipid bilayers: formation and evolution of pores
Glaser, R. W., Leikin, S. L., Chernomordik, L. V., Pastushenko, V. F., & Sokirko, A. I. (1988) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(88)90202-7 · Cited by 607 · cited 2×
“Nanopores could also be a brief initial stage of larger pore formation (Glaser et al. 1988).”
Intracellular effect of ultrashort electrical pulses
Schoenbach, K. H., Beebe, S. J., & Buescher, E. S. (2001) · Bioelectromagnetics · doi:10.1002/bem.71 · Cited by 548 · cited 2×
“... der Waals dimensions of propidium (Fig. 1) but disregarding any hydration layers (which are too difficult to estimate [Hille 2001] and are beyond the scope of this study), the maximum diameter of a propidium-impermeable pore can be estimated at about 1.5 nm. The diameter of pores formed by conventional electropora…”
InfluentialNanosecond, high‐intensity pulsed electric fields induce apoptosis in human cells
Beebe, S. J., Fox, P. M., Rec, L. J., Willis, L. K., & Schoenbach, K. H. (2003) · The FASEB Journal · doi:10.1096/fj.02-0859fje · Cited by 465 · cited 2×
“…exposed to ultrashort electric pulses (USEPs, \1 ls pulse duration) reported a lack of dye uptake and, consequently, lack of plasma membrane disruption (Beebe et al. 2003a, b; Pakhomov et al. 2004; Tekle et al. 2005; Vernier et al. A. M. Bowman O. M. Nesin O. N. Pakhomova A. G. Pakhomov (&) Frank…”
Cited by
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Cell death due to electroporation – A review
Batista Napotnik, T., Polajžer, T., & Miklavčič, D. (2021) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2021.107871 · Cited by 542
Equivalent Pulse Parameters for Electroporation
Pucihar, G., Krmelj, J., Reberšek, M., Napotnik, T., & Miklavčič, D. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2167232 · Cited by 214
“Larger molecules need more time and more intense electroporation to cross the electroporated membrane, which might be the reason for the observed threshold [60].”
BackgroundBatista Napotnik, T., Reberšek, M., Vernier, P. T., Mali, B., & Miklavčič, D. (2016) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2016.02.011 · Cited by 194
“With the use of different detecting methods, such as patch-clamp [27,28], Tl uptake [28,42], cell swelling [43,44] and phosphatidylserine (PS) externalization [26], it was suggested that plasma membrane pores of”
MethodOxidative effects of nanosecond pulsed electric field exposure in cells and cell-free media
Pakhomova, O. N., Khorokhorina, V. A., Bowman, A. M., Rodaitė-Riševičienė, R., Saulis, G., Xiao, S., & Pakhomov, A. G. (2012) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2012.08.004 · Cited by 188
Self-citationIn vitro electroporation detection methods – An overview
Batista Napotnik, T., & Miklavčič, D. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2017.12.005 · Cited by 187
“5 nm(molecularmass: 542Da), and iodide anions, although the term “PI uptake” is still nevertheless traditionally used in publications [17,56].”
BackgroundInfluentialInduction of Cell Death Mechanisms and Apoptosis by Nanosecond Pulsed Electric Fields (nsPEFs)
Beebe, S., Sain, N., & Ren, W. (2013) · Cells · doi:10.3390/cells2010136 · Cited by 185
Tutorial: Electroporation of cells in complex materials and tissue
Rems, L., & Miklavčič, D. (2016) · Journal of Applied Physics · doi:10.1063/1.4949264 · Cited by 180
de Ménorval, M.-A., Mir, L. M., Fernández, M. L., & Reigada, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0041733 · Cited by 178
“If it may enter the cell, as a DNA-intercalant dye it binds to DNA and become much more fluorescent than the free Yo-Pro-1 [23,24].”
BackgroundMethodNanosecond electric pulses cause mitochondrial membrane permeabilization in Jurkat cells
Napotnik, T. B., Wu, Y., Gundersen, M. A., Miklavčič, D., & Vernier, P. T. (2012) · Bioelectromagnetics · doi:10.1002/bem.20707 · Cited by 171
“We already know that YO-PRO-1 is a more sensitive indicator of plasma membrane permeabilization than Bioelectromagnetics PI [Vernier et al., 2006; Bowman et al., 2010], and we see evidence of PI influx with a 20-pulse exposure under the conditions we employed in this work, while at the same time…”
MethodPrimary pathways of intracellular Ca2+ mobilization by nanosecond pulsed electric field
Semenov, I., Xiao, S., & Pakhomov, A. G. (2013) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2012.11.032 · Cited by 164
“It has already been proposed earlier to employ nsPEF for heart pacing [16] and stimulation of catecholamine release [25,33], but better understanding of the nsPEF effects may open the way for numerous other applications.”
Self-citationBurke, R. C., Bardet, S. M., Carr, L., Romanenko, S., Arnaud-Cormos, D., Leveque, P., & O'Connor, R. P. (2017) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2017.07.004 · Cited by 58
Metadata
- Authors
- Bowman, A. M., Nesin, O. M., Pakhomova, O. N., & Pakhomov, A. G.
- Venue
- The Journal of Membrane Biology
- Published
- 2010-07
- Volume
- 236
- Issue
- 1
- Pages
- 15-26
- ISSN
- 0022-2631 (ISSN-L)
- 1432-1424
- OpenAlex
- W1980952670
- Cited by
- 192
- References
- 42
- FWCI
- 8.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.