Intracranial Nonthermal Irreversible Electroporation: In Vivo Analysis
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498 · cited 3×
“Although thermal damage can occur at lower temperatures for prolonged exposures, typically 43 C is chosen due to the abundant experimental data at this temperature (Sapareto and Dewey 1984; Dewhirst et al. 2003; Becker and Kuznetsov 2006).”
BackgroundMethodInfluentialPhysical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Tissue Ablation with Irreversible Electroporation
Davalos, R. V., Mir, L. M., & Rubinsky, B. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8981-8 · Cited by 1,293 · cited 6×
“To achieve NTIRE, the electric field in the targeted region needs to be above a critical value, which is dependent on a variety of conditions such as tissue properties, electrode configuration and pulse parameters; including strength, shape, duration, number and repetition rate (Macek-Lebar and Miklavcic 2001; Davalos…”
BackgroundInfluentialSelf-citationBasic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
Dewhirst, M. W., Viglianti, B. L., Lora-Michiels, M., Hanson, M., & Hoopes, P. J. (2003) · International Journal of Hyperthermia · doi:10.1080/0265673031000119006 · Cited by 1,014 · cited 1×
“Although thermal damage can occur at lower temperatures for prolonged exposures, typically 43 C is chosen due to the abundant experimental data at this temperature (Sapareto and Dewey 1984; Dewhirst et al. 2003; Becker and Kuznetsov 2006).”
BackgroundIrreversible Electroporation: A New Ablation Modality — Clinical Implications
Rubinsky, B., Onik, G., & Mikus, P. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600106 · Cited by 781 · cited 3×
“area and delivering a series of short and intense electric pulses to induce irrecoverable structural changes in cell membranes, ultimately resulting in the death of the cell (Rubinsky et al. 2007).”
BackgroundIn Vivo Results of a New Focal Tissue Ablation Technique: Irreversible Electroporation
Edd, J. F., Horowitz, L., Davalos, R. V., Mir, L. M., & Rubinsky, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873745 · Cited by 510 · cited 6×
“Since thermal damage is a function of temperature and length of exposure, the negligible thermal damage associated with this procedure can be explained by the fact that an electroporation pulse is typically a fraction of a second in duration (Al-Sakere et al. 2007a, b; Edd et al. 2006).”
BackgroundMethodResultInfluentialSelf-citationTumor Ablation with Irreversible Electroporation
Al-Sakere, B., André, F., Bernat, C., Connault, E., Opolon, P., Davalos, R. V., Rubinsky, B., & Mir, L. M. (2007) · PLoS ONE · doi:10.1371/journal.pone.0001135 · Cited by 490 · cited 5×
“Since thermal damage is a function of temperature and length of exposure, the negligible thermal damage associated with this procedure can be explained by the fact that an electroporation pulse is typically a fraction of a second in duration (Al-Sakere et al. 2007a, b; Edd et al. 2006).”
BackgroundMethodInfluentialSelf-citationIrreversible Electroporation in Medicine
Rubinsky, B. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600401 · Cited by 415 · cited 3×
“Researchers have shown that conductivity changes due to electroporation and joule heating can be incorporated in numerical models to produce more accurate predictions of treatment outcome (Davalos et al. 2004; Pavselj et al. 2005; Sel et al. 2005, 2007; Ivorra and Rubinsky 2007; Ivorra et al. 2009).”
BackgroundElectric and Thermal Field Effects in Tissue Around Radiofrequency Electrodes
Cosman, E. R., & Cosman, E. R. (2005) · Pain Medicine · doi:10.1111/j.1526-4637.2005.00076.x · Cited by 403 · cited 1×
“…distribution of the brain and electrodes was allowed to reach equilibrium before the onset of the treatment to provide an accurate temperature distribution from the NTIRE pulses (Table 2) (Werner and Buse 1988; Duck 1990; Uzuka et al. 2001; Cosman and Cosman 2005; Al-Sakere et al. 2007a, b).”
MethodIrreversible Electroporation: Implications for Prostate Ablation
Onik, G., Mikus, P., & Rubinsky, B. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600405 · Cited by 375 · cited 7×
“Previous NTIRE studies outside the central nervous system (CNS) have shown that ablation is rapid in onset and resolution, allowing early repopulation of the ablated region with healthy cells (Onik et al. 2007; Rubinsky et al. 2007).”
BackgroundMethodResultInfluential
Cited by
Electroporation-Based Technologies for Medicine: Principles, Applications, and Challenges
Yarmush, M. L., Golberg, A., Serša, G., Kotnik, T., & Miklavčič, D. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104622 · Cited by 889
Arena, C. B., Sano, M. B., Rossmeisl, J. H., Caldwell, J. L., Garcia, P. A., Rylander, M. N., & Davalos, R. V. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-102 · Cited by 361
Self-citationA Review of Basic to Clinical Studies of Irreversible Electroporation Therapy
Jiang, C., Davalos, R. V., & Bischof, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2367543 · Cited by 332
Self-citationNonthermal Irreversible Electroporation: Fundamentals, Applications, and Challenges
Golberg, A., & Yarmush, M. L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2238672 · Cited by 198
“Successful ablations were reported for brain [44], [47], [48], blood-brain barrier [47], prostate”
BackgroundAycock, K. N., & Davalos, R. V. (2019) · Bioelectricity · doi:10.1089/bioe.2019.0029 · Cited by 188
Self-citationPhysical energy for drug delivery; poration, concentration and activation
Lakshmanan, S., Gupta, G. K., Avci, P., Chandran, R., Sadasivam, M., Jorge, A. E. S., & Hamblin, M. R. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.010 · Cited by 185
Garcia, P. A., Davalos, R. V., & Miklavcic, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103083 · Cited by 174
“Conduction C 3600 500 3400 J/(kg?K) [28,44,48]”
BackgroundSelf-citationSano, M. B., Neal, R. E., Garcia, P. A., Gerber, D., Robertson, J., & Davalos, R. V. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-83 · Cited by 117
“Once a critical electric field intensity threshold is surpassed (approximately 500 [34] to 700 V/cm [35] for ninety 50 μs pulses at 4 Hz in brain and eight 100 μs pulses at 1 Hz in liver, respectively), the cell membrane is unable to recover and cell death is induced in a precise and controllable manner with sub-milli…”
BackgroundResultSelf-citation
Metadata
- Authors
- Garcia, P. A., Rossmeisl, J. H., Neal, R. E., Ellis, T. L., Olson, J. D., Henao-Guerrero, N., Robertson, J., & Davalos, R. V.
- Venue
- The Journal of Membrane Biology
- Published
- 2010-07
- Volume
- 236
- Issue
- 1
- Pages
- 127-136
- ISSN
- 0022-2631 (ISSN-L)
- 1432-1424
- OpenAlex
- W2044632997
- Cited by
- 162
- References
- 37
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.