Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 375

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Irreversible Electroporation: Implications for Prostate Ablation

Open access
Onik, Gary, Mikus, Paul, Rubinsky, Boris·2007·Technology in Cancer Research & Treatment

Abstract

Percutaneous prostate cryo-ablation has become an accepted treatment for primary prostate cancer. Thermal tissue ablation based on cold, however, does have some distinct limitations. These include, variable damage at the cryo lesions margin, injury to adjacent structures such as rectum, urethra and NVB (neurovascular bundle), and long procedure time due to the need for multiple freeze thaw cycles, that have limited the acceptance of this modality. Irreversible electroporation IRE, is a new non-thermal ablation modality that uses short pulses of DC electric current to create irreversible pore in the cell membrane, thus, causing cell death. This method theoretically should have significant advantages in ablating prostate tissue. Six males dogs had their prostates treated using IRE. Pulses were applied using a DC generator that delivered pulses in the microsecond range of duration, with a variable pulse interval and voltage range. IRE probes were placed percutaneously or trans-rectally using trans-rectal ultrasound guidance. In one of the dogs, the lesions were made purposely to include the rectum, urethra, and neurovascular bundle (NVB). Subjects were followed for 1 to 14 days before sacrifice. IRE lesions in the prostate had unique characteristics compared to thermal lesions. The margins of the IRE lesions was very distinct with a narrow zone of transition from normal to complete necrosis, there was complete destruction within the IRE lesion, and rapid resolution of the lesions with marked shrinkage within two weeks. Structures such as urethra, vessels, nerves, and rectum were unaffected by the IRE application. IRE lesions have characteristics that are distinctly different than thermal lesions. The differences could be very advantageous in a clinical setting, improving the results and acceptance of prostate ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/153303460700600405

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 375

Metadata

Authors
Onik, G., Mikus, P., & Rubinsky, B.
Venue
Technology in Cancer Research & Treatment
Published
2007-08
Volume
6
Issue
4
Pages
295-300
ISSN
  • 1533-0338 (ISSN-L)
  • 1533-0346
OpenAlex
W2112143708
Cited by
375
References
6
FWCI
13.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Irreversible Electroporation: Implications for Prostate Ablation. https://app.cochat.ai/papers/10.1177/153303460700600405
The paper
Onik, G., Mikus, P., & Rubinsky, B. (2007). Irreversible Electroporation: Implications for Prostate Ablation. Technology in Cancer Research & Treatment. https://doi.org/10.1177/153303460700600405

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.