CoChat

Liver uptake of free fatty acids in vivo in humans as determined with 14( R , S )-[ 18 F]fluoro-6-thia-heptadecanoic acid and PET

Iozzo, Patricia, Turpeinen, Anu K., Takala, Teemu, Oikonen, Vesa, Solin, Olof, Ferrannini, Ele, Nuutila, Pirjo, Knuuti, Juhani · 2003 · European Journal of Nuclear Medicine and Molecular Imaging

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Increased delivery of circulating free fatty acids (FFA) to the liver has been implicated in the pathogenesis and progression of diabetes. The liver is inaccessible for direct measurement in humans in vivo. We measured liver FFA uptake with positron emission tomography (PET) and 14( R, S)-[(18)F]fluoro-6-thia-heptadecanoic acid ([(18)F]FTHA) in healthy men. We evaluated the use of graphical analysis and linear fit to describe uptake data over time, and compared the use of metabolite-corrected vs uncorrected input functions. Rapid accumulation of tracer in the liver was observed with time, leading to progressively higher tissue to blood radioactivity ratios. Using metabolite-corrected input function curves, linear fit to the data ( r value) exceeded 0.99 in all subjects, during each fitting time frame. Values of liver FFA influx rate constant and uptake were 0.34+/-0.01 ml min(-1) ml(-1) and 0.20+/-0.02 micro mol min(-1) ml(-1), respectively, and were minimally affected by the choice of the fitting interval. Expressed per unit mass, liver FFA uptake was ~50 times higher than that reported in skeletal muscle; in the whole organ, FFA uptake was twice as high as in skeletal muscles. The use of metabolite-uncorrected input functions significantly worsened the spread of data around the fitted line and led to a remarkable underestimation of liver FFA uptake at all time intervals. In conclusion, our data provide non-invasive quantification of hepatic FFA uptake in humans, showing the…

Overview

Integrity signals

Registry

Crossref · 10.1007/s00259-003-1215-0

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 30

Metadata

Authors
Iozzo, P., Turpeinen, A. K., Takala, T., Oikonen, V., Solin, O., Ferrannini, E., Nuutila, P., & Knuuti, J.
Affiliations
  • University of Turku (FI)
  • Kuopio University Hospital (FI)
  • University of Pisa (IT)
Corresponding author
Iozzo, Patricia
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2003-08-01
Volume
30
Issue
8
Pages
1160-1164
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2055717322
Cited by
30
References
18
Citations by year
2025: 1 · 2024: 2 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 2 · 2015: 1 · 2014: 4 · 2012: 1
FWCI
0.54
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • European Journal of Nuclear Medicine and Molecular Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Hepatology › Liver Disease Diagnosis and Treatment
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Lipid metabolism and disorders
Keywords
free fatty acid uptake, liver, PET radiotracer, graphical method, linear fit, tissue-to-blood ratio
MeSH terms
Algorithms, Fatty Acids, Fatty Acids, Nonesterified, Humans, Image Interpretation, Computer-Assisted, Liver, Male, Metabolic Clearance Rate, Middle Aged, Models, Biological, Radioisotope Dilution Technique, Sensitivity and Specificity, Tissue Distribution, Tomography, Emission-Computed, Reproducibility of Results, Radiopharmaceuticals

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.