The DOI matches its Crossref record.
The Netherlands protocol for standardisation and quantification of FDG whole body PET studies in multi-centre trials
Open accessAbstract
INTRODUCTION: Several studies have shown the usefulness of positron emission tomography (PET) quantification using standardised uptake values (SUV) for diagnosis and staging, prognosis and response monitoring. Many factors affect SUV, such as patient preparation procedures, scan acquisition, image reconstruction and data analysis settings, and the variability in methodology across centres prohibits exchange of SUV data. Therefore, standardisation of 2-[(18)F] fluoro-2-deoxy-D-glucose (FDG) PET whole body procedures is required in multi-centre trials. METHODS: A protocol for standardisation of quantitative FDG whole body PET studies in the Netherlands (NL) was defined. This protocol is based on standardisation of: (1) patient preparation; (2) matching of scan statistics by prescribing dosage as function of patient weight, scan time per bed position, percentage of bed overlap and image acquisition mode (2D or 3D); (3) matching of image resolution by prescribing reconstruction settings for each type of scanner; (4) matching of data analysis procedure by defining volume of interest methods and SUV calculations and; (5) finally, a multi-centre QC procedure is defined using a 20-cm diameter phantom for verification of scanner calibration and the NEMA NU 2 2001 Image Quality phantom for verification of activity concentration recoveries (i.e., verification of image resolution and reconstruction convergence). DISCUSSION: This paper describes a protocol for standardization of quantitative FDG whole body multi-centre PET studies. CONCLUSION: The protocol was successfully implemented in the Netherlands and has been approved by the Netherlands Society of Nuclear Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
Self-citationA Systematic Review of the Factors Affecting Accuracy of SUV Measurements
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4923 · Cited by 662
De Ruysscher, D., Wanders, R., van Baardwijk, A., Dingemans, A.-M. C., Reymen, B., Houben, R., Bootsma, G., Pitz, C., van Eijsden, L., Geraedts, W., et al. (2012) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318262caf6 · Cited by 283
Hasenclever, D., Kurch, L., Mauz-Körholz, C., Elsner, A., Georgi, T., Wallace, H., Landman-Parker, J., Moryl-Bujakowska, A., Cepelová, M., Karlén, J., et al. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2715-9 · Cited by 157
Variations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136
Heusch, P., Buchbender, C., Beiderwellen, K., Nensa, F., Hartung-Knemeyer, V., Lauenstein, T. C., Bockisch, A., Forsting, M., Antoch, G., & Heusner, T. A. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.01.008 · Cited by 96
Reference Range for Intrapatient Variability in Blood-Pool and Liver SUV for 18F-FDG PET
Boktor, R. R., Walker, G., Stacey, R., Gledhill, S., & Pitman, A. G. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.108530 · Cited by 90
Instrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT
Doot, R. K., Scheuermann, J. S., Christian, P. E., Karp, J. S., & Kinahan, P. E. (2010) · Medical Physics · doi:10.1118/1.3499298 · Cited by 82
Variance of SUVs for FDG-PET/CT is Greater in Clinical Practice Than Under Ideal Study Settings
Kumar, V., Nath, K., Berman, C. G., Kim, J., Tanvetyanon, T., Chiappori, A. A., Gatenby, R. A., Gillies, R. J., & Eikman, E. A. (2013) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e318279ffdf · Cited by 76
Hagen, P. V., Heijl, M. V., van Berge Henegouwen, M. I., Boellaard, R., Bossuyt, P. M. M., Kate, F. J. W. T., Dekken, H. V., Hoekstra, O. S., Sloof, G. W., & Lanschot, J. J. B. V. (2017) · Diseases of the Esophagus · doi:10.1111/dote.12479 · Cited by 58
Self-citationIlan, E., Sandström, M., Velikyan, I., Sundin, A., Eriksson, B., & Lubberink, M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180380 · Cited by 34
Dosani, M., Yang, R., McLay, M., Wilson, D., Liu, M., Yong-Hing, C. J., Hamm, J., Lund, C. R., Olson, R., & Schellenberg, D. (2019) · Current Oncology · doi:10.3747/co.26.4167 · Cited by 28
Metadata
- Authors
- Boellaard, R., Oyen, W. J. G., Hoekstra, C. J., Hoekstra, O. S., Visser, E. P., Willemsen, A. T., Arends, B., Verzijlbergen, F. J., Zijlstra, J., Paans, A. M., Comans, E. F. I., & Pruim, J.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2008-08-15
- Volume
- 35
- Issue
- 12
- Pages
- 2320-2333
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W1995308403
- Cited by
- 396
- References
- 0
- FWCI
- 19.83
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.