A Systematic Review of the Factors Affecting Accuracy of SUV Measurements

Adams, Michael C., Turkington, Timothy G., Wilson, Joshua M., Wong, Terence Z.·2010·American Journal of Roentgenology

Abstract

OBJECTIVE: There is growing interest in using PET/CT for evaluating early response to therapy in cancer treatment. Although widely available and convenient to use, standardized uptake value (SUV) measurements can be influenced by a variety of biologic and technologic factors. Many of these factors can be addressed with close attention to detail and appropriate quality control. This article will review factors potentially affecting SUV measurements and provide recommendations on ways to minimize when using serial PET to assess early response to therapy. CONCLUSION: Scanner and reconstruction parameters can significantly affect SUV measurements. When using serial SUV measurements to assess early response to therapy, imaging should be performed on the same scanner using the same image acquisition and reconstruction protocols. In addition, attention to detail is required for accurate determination of the administered radiopharmaceutical dose.

Integrity signals

Registry

Crossref · 10.2214/ajr.10.4923

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The liver is the only reference region that has so far been studied and used extensively to eliminate or reduce the effect of factors such as body weight, obesity, blood glucose level, and 18F-FDG uptake time on SUVmax.

    “The liver is the only reference region that so far has been studied and used extensively to eliminate or reduce the effect of various factors such as body weight, obesity, the blood glucose level, and 18F-FDG uptake time on SUVmax;[32]”

    From Intrapatient variability of 18F-FDG uptake in normal tissues (2022) · cites this paper as [32]

  • Using quantitative PET for patient selection is difficult in clinical practice because SUV measurements not obtained in a well-conducted clinical trial are subject to variability due to technical factors such as the PET scanner used and the acquisition and reconstruction parameters.

    “Using quantitative PET for patient selection is difficult in clinical practice because SUV measurements not obtained in a well-conducted clinical trial are subject to variability. This is because of technical factors such as the PET scanner used and the acquisition and reconstruction parameters (23–26).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z.
Affiliations
Duke Medical Center (US)
Venue
American Journal of Roentgenology
Published
2010-08
Volume
195
Issue
2
Pages
310-320
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2168021523
Cited by
662
References
57
Citations by year
2026: 37 · 2025: 58 · 2024: 56 · 2023: 39 · 2022: 48 · 2021: 59 · 2020: 43 · 2019: 51 · 2018: 36 · 2017: 42 · 2016: 36 · 2015: 37 · 2014: 35 · 2013: 44 · 2012: 27
FWCI
3.90
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Roentgenology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
standardized uptake value, PET/CT, early response assessment, image acquisition protocol, quality control
MeSH terms
Algorithms, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Models, Biological, Neoplasms, Sensitivity and Specificity, Reproducibility of Results, Radiopharmaceuticals, Fluorodeoxyglucose F18, Positron-Emission Tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review