Partial volume correction strategies for quantitative FDG PET in oncology
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: Quantitative accuracy of positron emission tomography (PET) is affected by partial volume effects resulting in increased underestimation of the standardized uptake value (SUV) with decreasing tumour volume. The purpose of the present study was to assess accuracy and precision of different partial volume correction (PVC) methods. METHODS: Three methods for PVC were evaluated: (1) inclusion of the point spread function (PSF) within the reconstruction, (2) iterative deconvolution of PET images and (3) calculation of spill-in and spill-out factors based on tumour masks. Simulations were based on a mathematical phantom with tumours of different sizes and shapes. Phantom experiments were performed in 2-D mode using the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom containing six differently sized spheres. Clinical studies (2-D mode) included a test-retest study consisting of 10 patients with stage IIIB and IV non-small cell lung cancer and a response monitoring study consisting of 15 female breast cancer patients. In all studies tumour or sphere volumes of interest (VOI) were generated using VOI based on adaptive relative thresholds. RESULTS: Simulations and experiments provided similar results. All methods were able to accurately recover true SUV within 10% for spheres equal to and larger than 1 ml. Reconstruction-based recovery, however, provided up to twofold better precision than image-based methods. Clinical studies showed that PVC increased SUV by 5-80% depending on tumour size. Test-retest variability slightly worsened from 9.8 +/- 6.5 without to 10.8 +/- 7.9% with PVC. Finally, PVC resulted in slightly smaller SUV responses, i.e. from -30.5% without to -26.3% with PVC after the first cycle of treatment (p < 0.01). CONCLUSION: PVC improves accuracy of SUV without decreasing (clinical) test-retest variability significantly and it has a small, but significant effect on observed tumour responses. Reconstruction-based PVC outperforms image-based methods, but requires dedicated reconstruction software. Image-based methods are good alternatives because of their ease of implementation and their similar performance in clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Self-citationComparison of Gallium-68 and Fluorine-18 imaging characteristics in positron emission tomography
Sanchez-Crespo, A. (2013) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2012.06.034 · Cited by 276
van Velden, F. H. P., Cheebsumon, P., Yaqub, M., Smit, E. F., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1845-6 · Cited by 182
“Therefore, in the remainder of this article, only CSH data for PET+BF+CIT images will be provided.”
MethodInfluentialSelf-citationPET quantification: strategies for partial volume correction
Bettinardi, V., Castiglioni, I., De Bernardi, E., & Gilardi, M. C. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0066-y · Cited by 105
“Many PVE correction techniques have been proposed in the literature, with the aim of improving PET image quality and quantitative accuracy [8–12].”
BackgroundPET in the management of locally advanced and metastatic NSCLC
Grootjans, W., de Geus-Oei, L.-F., Troost, E. G. C., Visser, E. P., Oyen, W. J. G., & Bussink, J. (2015) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2015.75 · Cited by 97
Clinical evaluation of PET image reconstruction using a spatial resolution model
Andersen, F. L., Klausen, T. L., Loft, A., Beyer, T., & Holm, S. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.11.015 · Cited by 62
A method for model-free partial volume correction in oncological PET
Hofheinz, F., Langner, J., Petr, J., Beuthien-Baumann, B., Oehme, L., Steinbach, J., Kotzerke, J., & van den Hoff, J. (2012) · EJNMMI Research · doi:10.1186/2191-219x-2-16 · Cited by 55
Metadata
- Authors
- Hoetjes, N. J., van Velden, F. H. P., Hoekstra, O. S., Hoekstra, C. J., Krak, N. C., Lammertsma, A. A., & Boellaard, R.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2010-04-27
- Volume
- 37
- Issue
- 9
- Pages
- 1679-1687
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2135852974
- Cited by
- 154
- References
- 0
- FWCI
- 12.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.