Evaluation of a cumulative SUV-volume histogram method for parameterizing heterogeneous intratumoural FDG uptake in non-small cell lung cancer PET studies
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
PURPOSE: Standardized uptake values (SUV) are commonly used for quantification of whole-body [(18)F]fluoro-2-deoxy-D: -glucose (FDG) positron emission tomography (PET) studies. Changes in SUV following therapy, however, only provide a proper measure of response in case of homogeneous FDG uptake in the tumour. The purpose of this study was therefore to implement and characterize a method that enables quantification of heterogeneity in tumour FDG uptake. METHODS: Cumulative SUV-volume histograms (CSH), describing % of total tumour volume above % threshold of maximum SUV (SUV(max)), were calculated. The area under a CSH curve (AUC) is a quantitative index of tumour uptake heterogeneity, with lower AUC corresponding to higher degrees of heterogeneity. Simulations of homogeneous and heterogeneous responses were performed to assess the value of AUC-CSH for measuring uptake and/or response heterogeneity. In addition, partial volume correction and image denoising was applied prior to calculating AUC-CSH. Finally, the method was applied to a number of human FDG scans. RESULTS: Partial volume correction and noise reduction improved CSH curves. Both simulations and clinical examples showed that AUC-CSH values corresponded with level of tumour heterogeneity and/or heterogeneity in response. In contrast, this correspondence was not seen with SUV(max) alone. The results indicate that the main advantage of AUC-CSH above other measures, such as 1/COV (coefficient of variation), is the possibility to measure or normalize AUC-CSH in different ways. CONCLUSION: AUC-CSH might be used as a quantitative index of heterogeneity in tracer uptake. In response monitoring studies it can be used to address heterogeneity in response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
4D XCAT phantom for multimodality imaging research
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, J., & Tsui, B. M. W. (2010) · Medical Physics · doi:10.1118/1.3480985 · Cited by 1,287 · cited 1×
“Furthermore, it would be ideal to have a database or benchmark data set containing more realistically simulated anthropomorphic PET images based on e.g. Monte Carlo simulations [25, 26 ].”
BackgroundJan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794
(2004) · PubMed · Cited by 653
Surti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
(2005) · PubMed · Cited by 612
Larson, S. (1999) · Clinical Positron Imaging · doi:10.1016/s1095-0397(99)00016-3 · Cited by 598
Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.011 · Cited by 480 · cited 2×
“However, preliminary studies already indicated that other measures derived from the CSH, such as the % of volume derived at a fixed % of SUVor % of SUV derived at a fixed % of volume, could be used as a prognostic factor in NSCLC [28] and head and neck cancer [14].”
BackgroundA gradient-based method for segmenting FDG-PET images: methodology and validation
Geets, X., Lee, J. A., Bol, A., Lonneux, M., & Grégoire, V. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0363-4 · Cited by 419 · cited 1×
“In addition, PET images were denoised using an edge-preserving bilateral filter (BF) [ 22 ].”
MethodAvril, N. E., Menzel, M. M., Dose, J., Schelling, M., Weber, W., Jänicke, F., NATHRATH, W. B. J., & Schwaiger, M. (2001) · PubMed · Cited by 414
Nestle, U., Kremp, S., & Grosu, A.-L. (2006) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2006.09.011 · Cited by 214 · cited 1×
“In non-small cell lung cancer (NSCLC), positron emission tomography (PET) has been shown to be a valuable tool not only for detecting and staging the disease, but also for response monitoring, prediction of prognosis and estimation of target volume for radiotherapy purposes [1, 2 ]. To date, [ 18 F]fluoro-2-deoxy-D-gl…”
Method
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationApplications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Vallières, M., Freeman, C. R., Skamene, S. R., & El Naqa, I. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5471 · Cited by 897
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Radiomics strategies for risk assessment of tumour failure in head-and-neck cancer
Vallières, M., Kay-Rivest, E., Perrin, L. J., Liem, X., Furstoss, C., Aerts, H. J. W. L., Khaouam, N., Nguyen-Tan, P. F., Wang, C.-S., Sultanem, K., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-10371-5 · Cited by 542
Quantifying tumour heterogeneity in 18F-FDG PET/CT imaging by texture analysis
Chicklore, S., Goh, V., Siddique, M., Roy, A., Marsden, P. K., & Cook, G. J. R. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2247-0 · Cited by 488
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Hatt, M., Majdoub, M., Vallières, M., Tixier, F., Le Rest, C. C., Groheux, D., Hindié, E., Martineau, A., Pradier, O., Hustinx, R., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.144055 · Cited by 438
Cook, G. J. R., Yip, C., Siddique, M., Goh, V., Chicklore, S., Roy, A., Marsden, P., Ahmad, S., & Landau, D. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107375 · Cited by 394
Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Self-citationHatt, M., Tixier, F., Cheze Le Rest, C., Pradier, O., & Visvikis, D. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2486-8 · Cited by 208
“A variety of methodologies have been proposed to assess intratumour uptake heterogeneity, including visual assessment [21], SUV coefficient of variation (SUVcov) [20], area under the curve of the cumulative histogram (CHAUC) [22] and analysis of textural features [18].”
InfluentialDesseroit, M.-C., Tixier, F., Weber, W. A., Siegel, B. A., Cheze Le Rest, C., Visvikis, D., & Hatt, M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180919 · Cited by 160
PET Radiomics in NSCLC: state of the art and a proposal for harmonization of methodology
Sollini, M., Cozzi, L., Antunovic, L., Chiti, A., & Kirienko, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-00426-y · Cited by 158
The human box C/D snoRNAs U3 and U8 are required for pre-rRNA processing and tumorigenesis
Langhendries, J.-L., Nicolas, E., Doumont, G., Goldman, S., & Lafontaine, D. L. J. (2016) · Oncotarget · doi:10.18632/oncotarget.11148 · Cited by 97
A method for model-free partial volume correction in oncological PET
Hofheinz, F., Langner, J., Petr, J., Beuthien-Baumann, B., Oehme, L., Steinbach, J., Kotzerke, J., & van den Hoff, J. (2012) · EJNMMI Research · doi:10.1186/2191-219x-2-16 · Cited by 55
“deconvolution techniques [14-19], were the estimated resolution strongly influences the PVE correction.”
MethodNakajo, M., Jinguji, M., Nakajo, M., Shinaji, T., Nakabeppu, Y., Fukukura, Y., & Yoshiura, T. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1207-3 · Cited by 32
Metadata
- Authors
- van Velden, F. H. P., Cheebsumon, P., Yaqub, M., Smit, E. F., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2011-05-27
- Volume
- 38
- Issue
- 9
- Pages
- 1636-1647
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2050518967
- Cited by
- 182
- References
- 24
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.