Staging the axilla in breast cancer patients with 18F-FDG PET: how small are the metastases that we can detect with new generation clinical PET systems?
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: Point spread function (PSF) reconstruction improves spatial resolution throughout the entire field of view of a PET system and can detect smaller metastatic deposits than conventional algorithms such as OSEM. We assessed the impact of PSF reconstruction on quantitative values and diagnostic accuracy for axillary staging of breast cancer patients, compared with an OSEM reconstruction, with emphasis on the size of nodal metastases. METHODS: This was a prospective study in a single referral centre in which 50 patients underwent an (18)F-FDG PET examination before axillary lymph node dissection. PET data were reconstructed with an OSEM algorithm and PSF reconstruction, analysed blindly and validated by a pathologist who measured the largest nodal metastasis per axilla. This size was used to evaluate PET diagnostic performance. RESULTS: On pathology, 34 patients (68%) had nodal involvement. Overall, the median size of the largest nodal metastasis per axilla was 7 mm (range 0.5 - 40 mm). PSF reconstruction detected more involved nodes than OSEM reconstruction (p = 0.003). The mean PSF to OSEM SUVmax ratio was 1.66 (95 % CI 1.01 - 2.32). The sensitivities of PSF and OSEM reconstructions were, respectively, 96% and 92% in patients with a largest nodal metastasis of >7 mm, 60% and 40% in patients with a largest nodal metastasis of ≤7 mm, and 92% and 69% in patients with a primary tumour ≤30 mm. Biggerstaff graphical comparison showed that globally PSF reconstruction was superior to OSEM reconstruction. The median sizes of the largest nodal metastasis in patients with nodal involvement not detected by either PSF or OSEM reconstruction, detected by PSF but not by OSEM reconstruction and detected by both reconstructions were 3, 6 and 16 mm (p = 0.0064) respectively. In patients with nodal involvement detected by PSF reconstruction but not by OSEM reconstruction, the smallest detectable metastasis was 1.8 mm. CONCLUSION: As a result of better activity recovery, PET with PSF reconstruction performed better than PET with OSEM reconstruction in detecting nodal metastases ≤7 mm. However, its sensitivity is still insufficient for it to replace surgical approaches for axillary staging. PET with PSF reconstruction could be used to perform sentinel node biopsy more safely in patients with a primary tumour ≤30 mm and with unremarkable PET results in the axilla.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impact of Time-of-Flight on PET Tumor Detection
Kadrmas, D. J., Casey, M. E., Conti, M., Jakoby, B. W., Lois, C., & Townsend, D. W. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.063016 · Cited by 277 · cited 1×
“A 5-mm gaussian filter was applied to the OSEM images, but no postfiltering was used in the PSF images because PSF reconstruction has been shown to achieve maximal performance with little or no filtering [10].”
MethodAkamatsu, G., Ishikawa, K., Mitsumoto, K., Taniguchi, T., Ohya, N., Baba, S., Abe, K., & Sasaki, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.103861 · Cited by 206
Clinical evaluation of PET image reconstruction using a spatial resolution model
Andersen, F. L., Klausen, T. L., Loft, A., Beyer, T., & Holm, S. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.11.015 · Cited by 62 · cited 2×
“Finally, it is noteworthy that this study and others evaluating the impact of PSF reconstruction or a combination of PSF reconstruction and time-of-flight on quantitative values in oncology [7, 8, 24, 25] have been performed at a time when many efforts are being made to harmonize SUV values in multicentre trials [26–2…”
Background
Cited by
Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3740-2 · Cited by 344
Self-citationQuantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206
Quak, E., Le Roux, P.-Y., Hofman, M. S., Robin, P., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaun, P.-Y., Hicks, R. J., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3128-0 · Cited by 107
Self-citationNew PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
Self-citation
Metadata
- Authors
- Bellevre, D., Blanc Fournier, C., Switsers, O., Dugué, A. E., Levy, C., Allouache, D., Desmonts, C., Crouet, H., Guilloit, J.-M., Grellard, J.-M., & Aide, N.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2014-02-22
- Volume
- 41
- Issue
- 6
- Pages
- 1103-1112
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2049740511
- Cited by
- 58
- References
- 3
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Staging the axilla in breast cancer patients with 18F-FDG PET: how small are the metastases that we can detect with new generation clinical PET systems? https://app.cochat.ai/papers/10.1007/s00259-014-2689-7
- The paper
- Bellevre, D., Blanc Fournier, C., Switsers, O., Dugué, A. E., Levy, C., Allouache, D., Desmonts, C., Crouet, H., Guilloit, J.-M., Grellard, J.-M., & Aide, N. (2014). Staging the axilla in breast cancer patients with 18F-FDG PET: how small are the metastases that we can detect with new generation clinical PET systems? European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-014-2689-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.