Radiomics in nuclear medicine: robustness, reproducibility, standardization, and how to avoid data analysis traps and replication crisis
The DOI matches its Crossref record; 171 of the 174 references it cites were found in a registry or an index.
Abstract
Radiomics in nuclear medicine is rapidly expanding. Reproducibility of radiomics studies in multicentre settings is an important criterion for clinical translation. We therefore performed a meta-analysis to investigate reproducibility of radiomics biomarkers in PET imaging and to obtain quantitative information regarding their sensitivity to variations in various imaging and radiomics-related factors as well as their inherent sensitivity. Additionally, we identify and describe data analysis pitfalls that affect the reproducibility and generalizability of radiomics studies. After a systematic literature search, 42 studies were included in the qualitative synthesis, and data from 21 were used for the quantitative meta-analysis. Data concerning measurement agreement and reliability were collected for 21 of 38 different factors associated with image acquisition, reconstruction, segmentation and radiomics-specific processing steps. Variations in voxel size, segmentation and several reconstruction parameters strongly affected reproducibility, but the level of evidence remained weak. Based on the meta-analysis, we also assessed inherent sensitivity to variations of 110 PET image biomarkers. SUV mean and SUV max were found to be reliable, whereas image biomarkers based on the neighbourhood grey tone difference matrix and most biomarkers based on the size zone matrix were found to be highly sensitive to variations, and should be used with care in multicentre settings. Lastly, we identify 11 data analysis pitfalls. These pitfalls concern model validation and information leakage during model development, but also relate to reporting and the software used for data analysis. Avoiding such pitfalls is essential for minimizing bias in the results and to enable reproduction and validation of radiomics studies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Since there are many mature algorithms and software for radiomics, standardizing the process of radiomics, including image acquisition, segmentation, and feature extraction, can help to improve reproducibility 269,271,273.”
From Artificial intelligence in pancreatic cancer (2022) · cites this paper as [273]
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
XGBoost: A Scalable Tree Boosting System
Chen, T., & Guestrin, C. (2016) · Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining · doi:10.1145/2939672.2939785 · Cited by 54,569
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Research works printed but not linked: 3
- Hastie T, Tibshirani R, Friedman J. The Elements of Statistical Learning: Data Mining, Inference, and Prediction. Second ed. New York: Springer Science+Business Media; 2009.
- Guyon I, Elisseeff A. An introduction to variable and feature selection. J Mach Learn Res. 2003;3:1157–82.
- Fernández-Delgado M, Cernadas E, Barro S, Amorim D. Do we need hundreds of classifiers to solve real world classification problems? J Mach Learn Res. 2014;15:3133–81.
Cited by
Items 101–200 of 345
Yan, M., & Wang, W. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.555514 · Cited by 25
Marzi, C., Marfisi, D., Barucci, A., Meglio, J. D., Lilli, A., Vignali, C., Mascalchi, M., Casolo, G., Diciotti, S., Traino, C., et al. (2023) · Bioengineering · doi:10.3390/bioengineering10010080 · Cited by 24
Wang, K., Karalis, J. D., Elamir, A. M., Bifolco, A., Wachsmann, M., Capretti, G. L., Spaggiari, P., Enrico, S., Balasubramanian, K., Fatimah, N., et al. (2023) · Annals of Surgical Oncology · doi:10.1245/s10434-023-14805-5 · Cited by 24
Dondi, F., Pasinetti, N., Gatta, R., Albano, D., Giubbini, R., & Bertagna, F. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11030615 · Cited by 23
Hosseini, S. A., Shiri, I., Ghafarian, P., Hajianfar, G., Avval, A. H., Seyfi, M., Servaes, S., Rosa‐Neto, P., Zaidi, H., & Ay, M. R. (2024) · Annals of Nuclear Medicine · doi:10.1007/s12149-024-01923-7 · Cited by 23
Current challenges of the state-of-the-art of AI techniques for diagnosing brain tumor
Ahmed, H., Dada, M. O., & Samaila, B. B. (2023) · Material Science & Engineering International Journal · doi:10.15406/mseij.2023.07.00224 · Cited by 24
Zhong, J., Pan, Z., Chen, Y., Wang, L., Xia, Y., Wang, L., Li, J., Lu, W., Shi, X., Feng, J., et al. (2023) · Insights into Imaging · doi:10.1186/s13244-023-01426-5 · Cited by 23
Abler, D., Schaer, R., Oreiller, V., Verma, H., Reichenbach, J., Aidonopoulos, O., Évéquoz, F., Jreige, M., Prior, J. O., & Depeursinge, A. (2023) · European Radiology Experimental · doi:10.1186/s41747-023-00326-z · Cited by 22
Self-reported checklists and quality scoring tools in radiomics: a meta-research
Koçak, B., D’Antonoli, T. A., Kuş, E. A., Keleş, A., Kala, A., Köse, F., Kadıoğlu, M., Solak, S., Sunman, Ş., & Temiz, Z. H. (2024) · European Radiology · doi:10.1007/s00330-023-10487-5 · Cited by 22
Lv, W., Xu, H., Xu, H., Zhang, H., Ma, J., Rahmim, A., & Lu, L. (2022) · Cancers · doi:10.3390/cancers14071674 · Cited by 22
Keller, H., Shek, T. L. T., Driscoll, B., Xu, Y., Nghiem, B., Nehmeh, S. A., Grkovski, M., Schmidtlein, C. R., Budzevich, M. M., Balagurunathan, Y., et al. (2022) · Tomography · doi:10.3390/tomography8020091 · Cited by 22
SALİHOĞLU, Y. S., Erdemir, R. U., Püren, B. A., Özdemir, S., Uyulan, Ç., Erguzel, T. T., & Tekin, H. O. (2022) · Molecular Imaging and Radionuclide Therapy · doi:10.4274/mirt.galenos.2021.43760 · Cited by 21
Huang, Y., & Qian, H. (2024) · Journal of Hepatocellular Carcinoma · doi:10.2147/jhc.s493227 · Cited by 21
Carles, M., Fechter, T., Martí‐Bonmatí, L., Baltas, D., & Mix, M. D. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00390-7 · Cited by 21
Hindocha, S., Charlton, T., Linton‐Reid, K., Hunter, B., Hak, C. C. W., Ahmed, M., Greenlay, E. J., Orton, M. R., Bunce, C., Lunn, J., et al. (2022) · npj Precision Oncology · doi:10.1038/s41698-022-00322-3 · Cited by 20
Pasini, G., Russo, G. I., Mantarro, C., Bini, F., Richiusa, S., Morgante, L., Comelli, A., Russo, G. I., SABINI, M. G., Cosentino, S., et al. (2023) · Diagnostics · doi:10.3390/diagnostics13243640 · Cited by 20
radMLBench: A dataset collection for benchmarking in radiomics
Demircioğlu, A. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109140 · Cited by 20
Zhang, H., Lu, T., Wang, L., Xing, Y., Hu, Y., Xu, Z., Lu, J. A., Yang, J., Chu, J., Zhang, B., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11374-x · Cited by 20
The role of 18F-FDG PET/CT radiomics in lymphoma
Rizzo, A., Triumbari, E. K. A., Gatta, R., Boldrini, L., Racca, M., Mayerhoefer, M. E., & Annunziata, S. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00451-y · Cited by 20
Multicollinearity and redundancy of the PET radiomic feature set
Noortman, W. A., Vriens, D., Bussink, J., Meijer, T. W. H., Aarntzen, E. H. J. G., Deroose, C. M., Lhommel, R., Aide, N., Tourneau, C. L., de Koster, E. J., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11637-7 · Cited by 19
Zhong, J., Wu, Z., Wang, L., Chen, Y., Xia, Y., Wang, L., Li, J., Lu, W., Shi, X., Feng, J., et al. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-023-00901-1 · Cited by 19
Zhu, L., Dong, H., Sun, J., Wang, L., Xing, Y., Hu, Y., Lu, J. A., Yang, J., Chu, J., Yan, C., et al. (2024) · European Radiology · doi:10.1007/s00330-024-10976-1 · Cited by 19
Repeatability of radiomics studies in colorectal cancer: a systematic review
Liu, Y., Wei, X., Xu, F., Liu, Y., Feng, G., & Du, Y. (2023) · BMC Gastroenterology · doi:10.1186/s12876-023-02743-1 · Cited by 19
Hindocha, S., Hunter, B., Linton‐Reid, K., Charlton, T., Chen, M., Logan, A., Ahmed, M., Locke, I., Sharma, B., Doran, S., et al. (2024) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2024.110266 · Cited by 18
Linsalata, S., Borgheresi, R., Marfisi, D., Barca, P., Sainato, A., Paiar, F., Neri, E., Traino, C., & Giannelli, M. (2022) · BioMed Research International · doi:10.1155/2022/2003286 · Cited by 18
Wu, F., Wu, Y.-J., & Tang, E. (2023) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-22-308 · Cited by 18
Koçak, B., Yardımcı, A. H., Nazlı, M. A., Yüzkan, S., Mutlu, S., Güzelbey, T., Özdemir, M. Ş., Akin, M., Yücel, S., Bulut, E., et al. (2023) · European Journal of Radiology · doi:10.1016/j.ejrad.2023.110893 · Cited by 18
Effects of Tracer Uptake Time in Non–Small Cell Lung Cancer18F-FDG PET Radiomics
Kolinger, G. D., García, D. V., Kramer, G. M., Frings, V., Zwezerijnen, G. J. C., Smit, E. F., Langen, A. J. D., Buvat, I., & Boellaard, R. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262660 · Cited by 17
Sun, L., Smith, W., & Kirkby, C. (2023) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13904 · Cited by 17
Luining, W. I., Oprea‐Lager, D. E., Vis, A. N., van Moorselaar, R. J. A., Knol, R. J. J., Wondergem, M., Boellaard, R., & Cysouw, M. C. F. (2023) · PLoS ONE · doi:10.1371/journal.pone.0293672 · Cited by 17
Constantino, C. S., Oliveira, F. P. M., Silva, M., Oliveira, C., Castanheira, J. C., Silva, Â., Vaz, S. C., Vieira, P. M., & Costa, D. C. (2020) · European Radiology · doi:10.1007/s00330-020-07390-8 · Cited by 17
On dose cube pixel spacing pre-processing for features extraction stability in dosiomic studies
Placidi, L., Cusumano, D., Lenkowicz, J., Boldrini, L., & Valentini, V. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.09.010 · Cited by 17
Marturano, F., Guglielmo, P., Bettinelli, A., Zattoni, F., Novara, G., Zorz, A., Sepulcri, M., Gregianin, M., Paiusco, M., & Evangelista, L. (2023) · European Radiology · doi:10.1007/s00330-023-09642-9 · Cited by 16
Alves, V. R., Cardoso, J. S., & da Gama, J. M. P. (2023) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-023-00821-6 · Cited by 17
Tincani, M., Gilroy, S. P., & Dowdy, A. (2024) · Journal of Applied Behavior Analysis · doi:10.1002/jaba.2909 · Cited by 16
Artificial intelligence applications for oncological positron emission tomography imaging
Li, W., Liu, H., Cheng, F., Li, Y., Li, S., & Yan, J. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.109448 · Cited by 17
Xu, H., Lv, W., Zhang, H., Yuan, Q., Wang, Q., Wu, Y., & Lu, L. (2023) · European Radiology · doi:10.1007/s00330-023-09606-z · Cited by 15
Guglielmo, P., Marturano, F., Bettinelli, A., Sepulcri, M., Pasello, G., Gregianin, M., Paiusco, M., & Evangelista, L. (2023) · Diagnostics · doi:10.3390/diagnostics13132153 · Cited by 16
Barry, N., Rowshanfarzad, P., Francis, R. J., Nowak, A. K., & Ebert, M. A. (2021) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-021-01049-4 · Cited by 15
Byrd, C. T., Trope, W., Bhandari, P., Konsker, H. B., Moradi, F., Lui, N. S., Liou, D. Z., Backhus, L. M., Berry, M. F., & Shrager, J. B. (2022) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2022.02.055 · Cited by 15
Werner, R. A., Habacha, B., Lütje, S., Bundschuh, L., Kosmala, A., Essler, M., Derlin, T., Higuchi, T., Lapa, C., Buck, A. K., et al. (2023) · The Prostate · doi:10.1002/pros.24483 · Cited by 15
Oliveira, C., Oliveira, F. P. M., Vaz, S. C., Marques, H. P., & Cardoso, F. (2023) · British Journal of Radiology · doi:10.1259/bjr.20220655 · Cited by 15
Triumbari, E. K. A., Gatta, R., Maiolo, E., Summa, M. D., Boldrini, L., Mayerhoefer, M. E., Hohaus, S., Nardo, L., Morland, D., & Annunziata, S. (2023) · Diagnostics · doi:10.3390/diagnostics13081391 · Cited by 15
Jahanshahi, A., Soleymani, Y., Ghaziyani, M. F., & Khezerloo, D. (2023) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-023-01029-6 · Cited by 15
Aide, N., Elie, N., Blanc‐Fournier, C., Lévy, C., Salomon, T., & Lasnon, C. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2020.599050 · Cited by 14
Wang, W., Dai, J., Li, J., & Du, X. (2024) · Scientific Reports · doi:10.1038/s41598-024-60463-2 · Cited by 14
Floca, R. O., Bohn, J. R., Haux, C., Wiestler, B., Zöllner, F. G., Reinke, A., Weiß, J., Nolden, M., Albert, S., Persigehl, T., et al. (2024) · Insights into Imaging · doi:10.1186/s13244-024-01704-w · Cited by 14
Hoebers, F. J. P., Wee, L., Likitlersuang, J., Mak, R. H., Bitterman, D. S., Huang, Y., Dekker, A. L. A. J., Aerts, H. J. W. L., & Kann, B. H. (2023) · BJR|Open · doi:10.1093/bjro/tzae039 · Cited by 14
Bonci, E.-A., Bandura, A., Dooley, A., Erjan, A., Gebreslase, H. W., Hategan, M., Khanduja, D., Lai, E., Lescaie, A., Nițescu, G. V., et al. (2025) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2025.104929 · Cited by 14
Comte, V., Schmutz, H., Chardin, D., Orlhac, F., Darcourt, J., & Humbert, O. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05816-7 · Cited by 14
A role for artificial intelligence in molecular imaging of infection and inflammation
Schwenck, J., Kneilling, M., Riksen, N. P., la Fougère, C., Mulder, D. J., Slart, R., & Aarntzen, E. H. J. G. (2022) · European Journal of Hybrid Imaging · doi:10.1186/s41824-022-00138-1 · Cited by 14
Balma, M., Laudicella, R., Gallio, E., Gusella, S., Lorenzon, L., Peano, S., Costa, R. P., Rampado, O., Farsad, M., Evangelista, L., et al. (2023) · Life · doi:10.3390/life13081647 · Cited by 14
Ren, C., Zhang, F., Zhang, J., Song, S., Sun, Y., & Cheng, J. (2023) · European journal of medical research · doi:10.1186/s40001-023-01497-6 · Cited by 14
Long-axial field-of-view PET/CT improves radiomics feature reliability
Alberts, I., Xue, S., Sari, H., Cavinato, L., Prenosil, G., Afshar‐Oromieh, A., Mingels, C., Shi, K., Caobelli, F., Rahmim, A., et al. (2024) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-024-06921-5 · Cited by 13
Bodalal, Z., Wamelink, I. J. H. G., Trebeschi, S., & Beets‐Tan, R. G. H. (2021) · Immuno-Oncology Technology · doi:10.1016/j.iotech.2021.100028 · Cited by 13
Xing, J., Liu, Y., Wang, Z., Xu, A., Su, S., Shen, S., & Wang, Z. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1036734 · Cited by 13
Duan, C., Chaovalitwongse, W. A., Bai, F., Hippe, D. S., Wang, S., Thammasorn, P., Pierce, L. A., Liu, X., You, J., Miyaoka, R. S., et al. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abb0c7 · Cited by 14
Use of radiomics in the radiation oncology setting: Where do we stand and what do we need?
Schick, U., Lucia, F., Bourbonne, V., Dissaux, G., Pradier, O., Jaouen, V., Tixier, F., Visvikis, D., & Hatt, M. (2020) · Cancer/Radiothérapie · doi:10.1016/j.canrad.2020.07.005 · Cited by 13
Zhou, Y., Zhang, B., Han, J., Dai, N., Jia, T., Huang, H., Deng, S., & Sang, S. (2023) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-023-05038-w · Cited by 12
Lu, D., Yan, Y., Jiang, M., Sun, S., Jiang, H., Lu, Y., Zhang, W., & Zhou, X. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1173090 · Cited by 12
Nuclear medicine radiomics in precision medicine: why we can't do without artificial intelligence
Noortman, W. A., Vriens, D., Grootjans, W., Tao, Q., de Geus‐Oei, L., & van Velden, F. H. P. (2020) · The Quarterly Journal of Nuclear Medicine and Molecular Imaging · doi:10.23736/s1824-4785.20.03263-x · Cited by 14
Veres, G., Vas, N. F., Lassen, M. L., Béresová, M., Krizsan, A. K., Forgács, A., Berényi, E. L., & Balkay, L. (2021) · PLoS ONE · doi:10.1371/journal.pone.0253419 · Cited by 12
Cheng, N.-M., Hsieh, R. C.-E., Fang, Y.-H. D., Liao, C., Ng, S., Wang, H., Chou, W., Lin, C., & Yen, T. (2020) · EJNMMI Research · doi:10.1186/s13550-020-00631-3 · Cited by 12
Peng, L., Xu, H., Lv, W., Lu, L., & Chen, W. (2023) · Cancers · doi:10.3390/cancers15030932 · Cited by 11
Chen, M., Wang, K., Dohopolski, M. J., Morgan, H., Sher, D. J., & Wang, J. (2025) · Medical Physics · doi:10.1002/mp.17655 · Cited by 11
Radiomics and radiogenomics in ovarian cancer: a review with a focus on ultrasound applications
Huang, Y., Peng, W., Yang, H., Liu, Z., Zhang, T., Jin, L., He, W., Du, M., & Chen, Z. (2025) · Cancer Imaging · doi:10.1186/s40644-025-00950-5 · Cited by 11
Wang, P., Chen, K., Han, Y., Zhao, M., Nanding, A., Shang, J., Yan, S., Peng, H., Shang, N., & Meng, W. (2023) · Future Oncology · doi:10.2217/fon-2022-1025 · Cited by 11
Oliveira, C., Oliveira, F. P. M., Constantino, C. S., Alves, C., Brito, M. J., Cardoso, F., & Costa, D. C. (2024) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-024-06815-6 · Cited by 11
An assessment of PET and CMR radiomic features for the detection of cardiac sarcoidosis
Mushari, N. A., Soultanidis, G. M., Duff, L. M., Trivieri, M. G., Fayad, Z. A., Robson, P. M., & Tsoumpas, C. (2024) · Frontiers in Nuclear Medicine · doi:10.3389/fnume.2024.1324698 · Cited by 10
Radiolabeling of bionanomaterials with technetium 99m: current state and future prospects
Trusova, V. M., Karnaukhov, I. M., Zelinsky, A. Y., Borts, B., Ушаков, І. В., Sidenko, L., & Gorbenko, G. P. (2024) · Nanomedicine · doi:10.1080/17435889.2024.2368454 · Cited by 10
The role of PET radiomic features in prostate cancer: a systematic review
Quartuccio, N., Marrale, M., Laudicella, R., Alongi, P., Siracusa, M., Sturiale, L., Arnone, G., Cutaia, G., Salvaggio, G., Midiri, M., et al. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00436-x · Cited by 10
Anatomy and Physiology of Artificial Intelligence in PET Imaging
Bradshaw, T., & McMillan, A. B. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.003 · Cited by 10
Lue, K., Chu, S., Wang, L.-Y., Chen, Y., Li, M.-H., Chang, B.-S., Chan, S.-C., Chen, Y.-H., Lin, C., & Liu, S. (2021) · Annals of Nuclear Medicine · doi:10.1007/s12149-021-01698-1 · Cited by 10
Noise sensitivity of 89Zr-Immuno-PET radiomics based on count-reduced clinical images
Somasundaram, A., García, D. V., Pfaehler, E. A. G., Jauw, Y. W. S., Zijlstra, J. M., van Dongen, G. A. M. S., van Oordt, C. W. M. D. H., Huisman, M. C., de Vries, E. G. E., & Boellaard, R. (2022) · EJNMMI Physics · doi:10.1186/s40658-022-00444-4 · Cited by 10
Schurink, N. W., van Kranen, S. R., van Griethuysen, J. J. M., Roberti, S., Snæbjörnsson, P., Bakers, F. C. H., de Bie, S. H., Bosma, G. P. T., Cappendijk, V. C., Geenen, R. W. F., et al. (2023) · European Radiology · doi:10.1007/s00330-023-09920-6 · Cited by 10
Artificial intelligence‐assisted theranostics for brain tumors: Advancements and future perspectives
Li, M., Zhang, L., Ullah, Z., Zhang, Y., Wei, S., Huang, L., & Guo, B. (2025) · View · doi:10.1002/viw.20250119 · Cited by 9
Ahn, H., Song, G. J., Jang, S., Son, M. W., Lee, H. J., Lee, M., Lee, J., Oh, M., Jeong, G., Yun, J. H., et al. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms231911985 · Cited by 9
Zhao, F., Huang, X., He, J., Li, J., Li, Q., Wei, F., Chen, H., & Su, J. (2023) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-023-05032-2 · Cited by 9
Huang, W., Tao, Z., Younis, M. H., Cai, W., & Kang, L. (2023) · View · doi:10.1002/viw.20230032 · Cited by 9
Oriuchi, N., Endoh, H., & Kaira, K. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23169394 · Cited by 9
Chen, Y., Kan, K., Liu, S., Lin, H., & Lue, K. (2023) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.14200 · Cited by 9
Dwivedi, P., Barage, S. H., Jha, A. K., Choudhury, S., & Rangarajan, V. (2025) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.124.268252 · Cited by 9
Fuchs, T., Kaiser, L., Müller, D., Papp, L., Fischer, R., & Tran‐Gia, J. (2023) · Nuklearmedizin - NuclearMedicine · doi:10.1055/a-2187-5701 · Cited by 9
Kallos-Balogh, P., Vas, N. F., Toth, Z. G., Szakáll, S., Szabo, P., Garai, I., Képes, Z., Forgács, A., Egeresi, L. S., Magnus, D., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0309540 · Cited by 8
Value of PET imaging for radiation therapy
Lapa, C., Nestle, U., Albert, N. L., Baues, C., Beer, A. J., Buck, A. K., Budach, V., Bütof, R., Combs, S. E., Derlin, T., et al. (2021) · Nuklearmedizin - NuclearMedicine · doi:10.1055/a-1525-7029 · Cited by 8
Chen, M., Rong, J., Zhao, J.-C., Teng, Y., Chen, J., Jiang, C., & Xu, J. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1394450 · Cited by 8
D’Antonoli, T. A., Santini, F., Deligianni, X., Alzamora, M. G., Rutz, E., Bieri, O., Brunner, R., & Weidensteiner, C. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.633808 · Cited by 8
Duan, J., Qiu, Q., Zhu, J., Shang, D., Dou, X., Sun, T., Yin, Y., & Meng, X. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.881931 · Cited by 8
Zhong, J., Xing, Y., Zhang, G., Hu, Y., Ding, D., Ge, X., Pan, Z., Yin, Q., Zhang, H., Yang, Q., et al. (2023) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-023-03863-w · Cited by 8
EJNMMI supplement: bringing AI and radiomics to nuclear medicine
Veit‐Haibach, P., Buvat, I., & Herrmann, K. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04395-4 · Cited by 8
Editorial: Artificial Intelligence in Positron Emission Tomography
Fang, H., Shi, K., Wang, X., Zuo, C., & Lan, X. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.848336 · Cited by 8
Segmentation of Variants of Nuclei on Whole Slide Images by Using Radiomic Features
Sheikh, T. S., & Cho, M. (2024) · Bioengineering · doi:10.3390/bioengineering11030252 · Cited by 7
Imaging Cancer-associated Cachexia: Utilizing Clinical Imaging Modalities for Early Diagnosis
Jiang, Y., Zhao, Y., Dai, J., Yang, Q., Tang, X., Fu, L., Mao, H. Z., & Peng, X. (2025) · Radiology Imaging Cancer · doi:10.1148/rycan.240291 · Cited by 7
Duan, C., An, L., Yang, Y., Yuan, L., Zhu, Y., Han, Q., Ma, H., Zhao, F., & Yu, Q. (2025) · Cancer Management and Research · doi:10.2147/cmar.s529589 · Cited by 7
Teng, X., Luo, Q.-N., Chen, Y., & Peng, T. (2025) · Discover Oncology · doi:10.1007/s12672-025-03620-x · Cited by 8
Li, J., Zhang, B., Ge, S., Deng, S., Hu, C., & Sang, S. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.1047905 · Cited by 7
Comparison of three freeware software packages for 18F-FDG PET texture feature calculation
Larobina, M., Megna, R., & Solla, R. (2021) · Japanese Journal of Radiology · doi:10.1007/s11604-021-01100-0 · Cited by 7
Peng, S., Spetsieris, P. G., Eidelberg, D., & Ma, Y. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2020.04.33 · Cited by 7
Replication study of PD-L1 status prediction in NSCLC using PET/CT radiomics
Stüber, A. T., Heimer, M. M., Ta, J., Fabritius, M. P., Hoppe, B. F., Sheikh, G. T., Brendel, M., Unterrainer, L. M., Jurmeister, P. S., Tufman, A., et al. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111825 · Cited by 6
Triumbari, E. K. A., Morland, D., Gatta, R., Boldrini, L., Summa, M. D., Chiesa, S., Cuccaro, A., Maiolo, E., Hohaus, S., & Annunziata, S. (2025) · Annals of Hematology · doi:10.1007/s00277-025-06190-8 · Cited by 6
Metadata
- Authors
- Zwanenburg, A.
- Affiliations
- German Cancer Research Center (DE)
- Corresponding author
- Zwanenburg, Alex
- ORCID
- Zwanenburg, Alex
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2019-06-25
- Volume
- 46
- Issue
- 13
- Pages
- 2638-2655
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2954296981
- Semantic Scholar
- 4615abcf66a67c1823ef58feab4525cb360292fe
- Cited by
- 306
- References
- 174
- Citations by year
- 2026: 16 · 2025: 39 · 2024: 44 · 2023: 51 · 2022: 50 · 2021: 55 · 2020: 48 · 2019: 2
- FWCI
- 25.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- European Journal of Nuclear Medicine and Molecular Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image Retrieval and Classification Techniques
- Keywords
- radiomics, positron emission tomography, reproducibility, multicenter study, voxel size, image segmentation, image reconstruction parameters, SUVmax, SUVmean, data analysis pitfalls, information leakage, model validation, reporting bias, standardization
- MeSH terms
- Data Analysis, Humans, Image Processing, Computer-Assisted, Nuclear Medicine, Reference Standards
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.