Radiomics in nuclear medicine: robustness, reproducibility, standardization, and how to avoid data analysis traps and replication crisis
The DOI matches its Crossref record; 171 of the 174 references it cites were found in a registry or an index.
Abstract
Radiomics in nuclear medicine is rapidly expanding. Reproducibility of radiomics studies in multicentre settings is an important criterion for clinical translation. We therefore performed a meta-analysis to investigate reproducibility of radiomics biomarkers in PET imaging and to obtain quantitative information regarding their sensitivity to variations in various imaging and radiomics-related factors as well as their inherent sensitivity. Additionally, we identify and describe data analysis pitfalls that affect the reproducibility and generalizability of radiomics studies. After a systematic literature search, 42 studies were included in the qualitative synthesis, and data from 21 were used for the quantitative meta-analysis. Data concerning measurement agreement and reliability were collected for 21 of 38 different factors associated with image acquisition, reconstruction, segmentation and radiomics-specific processing steps. Variations in voxel size, segmentation and several reconstruction parameters strongly affected reproducibility, but the level of evidence remained weak. Based on the meta-analysis, we also assessed inherent sensitivity to variations of 110 PET image biomarkers. SUV mean and SUV max were found to be reliable, whereas image biomarkers based on the neighbourhood grey tone difference matrix and most biomarkers based on the size zone matrix were found to be highly sensitive to variations, and should be used with care in multicentre settings. Lastly, we identify 11 data analysis pitfalls. These pitfalls concern model validation and information leakage during model development, but also relate to reporting and the software used for data analysis. Avoiding such pitfalls is essential for minimizing bias in the results and to enable reproduction and validation of radiomics studies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Since there are many mature algorithms and software for radiomics, standardizing the process of radiomics, including image acquisition, segmentation, and feature extraction, can help to improve reproducibility 269,271,273.”
From Artificial intelligence in pancreatic cancer (2022) · cites this paper as [273]
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
XGBoost: A Scalable Tree Boosting System
Chen, T., & Guestrin, C. (2016) · Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining · doi:10.1145/2939672.2939785 · Cited by 54,569
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Research works printed but not linked: 3
- Hastie T, Tibshirani R, Friedman J. The Elements of Statistical Learning: Data Mining, Inference, and Prediction. Second ed. New York: Springer Science+Business Media; 2009.
- Guyon I, Elisseeff A. An introduction to variable and feature selection. J Mach Learn Res. 2003;3:1157–82.
- Fernández-Delgado M, Cernadas E, Barro S, Amorim D. Do we need hundreds of classifiers to solve real world classification problems? J Mach Learn Res. 2014;15:3133–81.
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
“Because of this variability, features that can be reproduced from the same image using standardized radiomics software may nevertheless lack reproducibility in multicentric or multiscanner settings (14,19,33).”
BackgroundSelf-citationMayerhoefer, M. E., Materka, A., Langs, G., Häggström, I., Szczypiński, P., Gibbs, P., & Cook, G. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.222893 · Cited by 1,777
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Kocak, B., Baessler, B., Bakas, S., Cuocolo, R., Fedorov, A., Maier-Hein, L., Mercaldo, N., Müller, H., Orlhac, F., Pinto dos Santos, D., et al. (2023) · Insights into Imaging · doi:10.1186/s13244-023-01415-8 · Cited by 471
Self-citationKhalighi, S., Reddy, K., Midya, A., Pandav, K. B., Madabhushi, A., & Abedalthagafi, M. (2024) · npj Precision Oncology · doi:10.1038/s41698-024-00575-0 · Cited by 306
Kocak, B., Akinci D’Antonoli, T., Mercaldo, N., Alberich-Bayarri, A., Baessler, B., Ambrosini, I., Andreychenko, A. E., Bakas, S., Beets-Tan, R. G. H., Bressem, K., et al. (2024) · Insights into Imaging · doi:10.1186/s13244-023-01572-w · Cited by 302
Self-citationWhybra, P., Zwanenburg, A., Andrearczyk, V., Schaer, R., Apte, A. P., Ayotte, A., Baheti, B., Bakas, S., Bettinelli, A., Boellaard, R., et al. (2024) · Radiology · doi:10.1148/radiol.231319 · Cited by 239
“Yet, the results of a radiomics analysis also depend on image acquisition, reconstruction, segmentation, and data analysis steps (19,20), which we did not address here or in our previous work.”
BackgroundSelf-citationPapadimitroulas, P., Brocki, L., Christopher Chung, N., Marchadour, W., Vermet, F., Gaubert, L., Eleftheriadis, V., Plachouris, D., Visvikis, D., Kagadis, G. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.009 · Cited by 226
“In addition, the developed models are rarely tested on external datasets, even less often on several ones [125,126].”
BackgroundHatt, M., Krizsan, A. K., Rahmim, A., Bradshaw, T., Costa, P. F., Forgács, A., Seifert, R., Zwanenburg, A., Naqa, I. E., Kinahan, P. E., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-06001-6 · Cited by 177
Self-citationHarmonization strategies for multicenter radiomics investigations
Da-Ano, R., Visvikis, D., & Hatt, M. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aba798 · Cited by 161
“Consequently, most published radiomic models have not been externally validated (Zwanenburg and Löck),(Zwanenburg 2019).”
BackgroundMethodCysouw, M. C. F., Jansen, B. H. E., van de Brug, T., Oprea‐Lager, D. E., Pfaehler, E. A. G., de Vries, B. M., van Moorselaar, R. J. A., Hoekstra, O. S., Vis, A. N., & Boellaard, R. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04971-z · Cited by 156
A decade of radiomics research: are images really data or just patterns in the noise?
Pinto dos Santos, D., Dietzel, M., & Baessler, B. (2021) · European Radiology · doi:10.1007/s00330-020-07108-w · Cited by 130
Artificial intelligence in pancreatic cancer
Huang, B., Huang, H., Zhang, S., Zhang, D., Shi, Q., Liu, J., & Guo, J. (2022) · Theranostics · doi:10.7150/thno.77949 · Cited by 142
“Since there are many mature algorithms and software for radiomics, standardizing the process of radiomics, including image acquisition, segmentation, and feature extraction, can help to improve reproducibility [269,271,273].”
MethodRadiomics in radiation oncology—basics, methods, and limitations
Lohmann, P., Bousabarah, K., Hoevels, M., & Treuer, H. (2020) · Strahlentherapie und Onkologie · doi:10.1007/s00066-020-01663-3 · Cited by 135
Lan, T., Kuang, S., Liang, P., Ning, C., Li, Q., Wang, L., Wang, Y., Lin, Z., Hu, H., Yang, L., et al. (2024) · International Journal of Surgery · doi:10.1097/js9.0000000000001578 · Cited by 112
Orlhac, F., Nioche, C., Klyuzhin, I. S., Rahmim, A., & Buvat, I. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.007 · Cited by 107
Benchmarking Feature Selection Methods in Radiomics
Demircioğlu, A. (2022) · Investigative Radiology · doi:10.1097/rli.0000000000000855 · Cited by 103
Aide, N., Fruchart, C., Nganoa, C., Gac, A., & Lasnon, C. (2020) · European Radiology · doi:10.1007/s00330-020-06815-8 · Cited by 99
Alberts, I., Sari, H., Mingels, C., Afshar‐Oromieh, A., Pyka, T., Shi, K., & Rominger, A. (2023) · Cancer Imaging · doi:10.1186/s40644-023-00540-3 · Cited by 98
Shiri, I., Amini, M., Nazari, M., Hajianfar, G., Avval, A. H., Abdollahi, H., Oveisi, M., Arabi, H., Rahmim, A., & Zaidi, H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105230 · Cited by 93
Ammari, S., Pitre-Champagnat, S., Dercle, L., Chouzenoux, É., Moalla, S., Reuzé, S., Talbot, H., Mokoyoko, T., Hadchiti, J., Diffetocq, S., et al. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2020.541663 · Cited by 86
Koçak, B. (2022) · Diagnostic and Interventional Radiology · doi:10.5152/dir.2022.211297 · Cited by 85
Applying oversampling before cross-validation will lead to high bias in radiomics
Demircioğlu, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-62585-z · Cited by 85
Radiomics in PET/CT: Current Status and Future AI-Based Evolutions
Hatt, M., Rest, C. C. L., Antonorsi, N., Tixier, F., Tankyevych, O., Jaouen, V., Lucia, F., Bourbonne, V., Schick, U., Badic, B., et al. (2020) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2020.09.002 · Cited by 81
PET/CT radiomics in breast cancer: Mind the step
Sollini, M., Cozzi, L., Ninatti, G., Antunovic, L., Cavinato, L., Chiti, A., & Kirienko, M. (2020) · Methods · doi:10.1016/j.ymeth.2020.01.007 · Cited by 78
Spohn, S. K. B., Bettermann, A. S., Bamberg, F., Benndorf, M., Mix, M. D., Nicolay, N. H., Fechter, T., Hölscher, T., Grosu, R., Chiti, A., et al. (2021) · Theranostics · doi:10.7150/thno.61207 · Cited by 77
Das, S., & Nazir, M. S. (2022) · doi:10.63125/q3r4kk16 · Cited by 78
Song, J., Wang, L., Ng, N. N., Zhao, M., Shi, J., Wu, N., Li, W., Liu, Z., Yeom, K. W., & Tian, J. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.30442 · Cited by 74
Liberini, V., Laudicella, R., Balma, M., Nicolotti, D. G., Buschiazzo, A., Grimaldi, S., Lorenzon, L., Bianchi, A., Peano, S., Bartolotta, T. V., et al. (2022) · European Radiology Experimental · doi:10.1186/s41747-022-00282-0 · Cited by 71
Current Advances and Challenges in Radiomics of Brain Tumors
Yi, Z., Long, L., Zeng, Y., & Liu, Z. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.732196 · Cited by 70
Ren, C., Zhang, J., Qi, M., Zhang, J., Zhang, Y., Song, S., Sun, Y., & Cheng, J. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05065-6 · Cited by 69
Kothari, G., Korte, J. C., Lehrer, E. J., Zaorsky, N. G., Lazarakis, S., Kron, T., Hardcastle, N., & Siva, S. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.10.023 · Cited by 69
Standardised convolutional filtering for radiomicsPreprint
Depeursinge, A., Andrearczyk, V., Whybra, P., van Griethuysen, J. J. M., Müller, H., Schaer, R., Vallières, M., & Zwanenburg, A. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2006.05470 · Cited by 69
Self-citationAmini, M., Hajianfar, G., Avval, A. H., Nazari, M., Deevband, M. R., Oveisi, M., Shiri, I., & Zaidi, H. (2021) · Clinical Oncology · doi:10.1016/j.clon.2021.11.014 · Cited by 68
Belli, M. L., Mori, M., Broggi, S., Cattaneo, G. M., Bettinardi, V., Dell’Oca, I., Fallanca, F., Passoni, P., Vanoli, E. G., Calandrino, R., et al. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.05.013 · Cited by 67
Kirienko, M., Ninatti, G., Cozzi, L., Voulaz, E., Gennaro, N., Barajon, I., Ricci, F., Carlo‐Stella, C., Zucali, P. A., Sollini, M., et al. (2020) · La radiologia medica · doi:10.1007/s11547-020-01188-w · Cited by 63
Shiri, I., Sadr, A. V., Amini, M., Salimi, Y., Sanaat, A., Akhavanallaf, A., Razeghi, B., Ferdowsi, S., Saberi, A., Arabi, H., et al. (2022) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000004194 · Cited by 61
A Multicentre Evaluation of Dosiomics Features Reproducibility, Stability and Sensitivity
Placidi, L., Gioscio, E., Garibaldi, C., Rancati, T., Fanizzi, A., Maestri, D., Massafra, R., Menghi, E., Mirandola, A., Reggiori, G., et al. (2021) · Cancers · doi:10.3390/cancers13153835 · Cited by 61
Shang, Y., Chen, W., Li, G., Huang, Y., Wang, Y., Kui, X., Li, M., Zheng, H., Zhao, W., & Liu, J. (2023) · La radiologia medica · doi:10.1007/s11547-023-01722-6 · Cited by 60
Koçak, B., Kuş, E. A., & Kılıçkesmez, Ö. (2020) · European Radiology · doi:10.1007/s00330-020-07324-4 · Cited by 60
Huynh, B. N., Groendahl, A. R., Tomić, O., Liland, K. H., Knudtsen, I. S., Hoebers, F. J. P., van Elmpt, W., Malinen, E., Dale, E., & Futsæther, C. M. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1217037 · Cited by 57
Leithner, D., Schöder, H. M., Haug, A. R., Vargas, H. A., Gibbs, P., Häggström, I., Rausch, I., Weber, M., Becker, A. S., Schwartz, J., et al. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.263102 · Cited by 56
Crombé, A., Fadli, D., Italiano, A., Saut, O., Buy, X., & Kind, M. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.109283 · Cited by 54
Liberini, V., Huellner, M. W., Grimaldi, S., Finessi, M., Thuillier, P., Muni, A., Pellerito, R. E., Papotti, M. G., Piovesan, A., Arvat, E., et al. (2020) · Diagnostics · doi:10.3390/diagnostics10121083 · Cited by 56
Ferrante, M., Rinaldi, L. M., Botta, F., Hu, X., Dolp, A., Minotti, M., Piano, F. D., Funicelli, G., Volpe, S., Bellerba, F., et al. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11247334 · Cited by 51
Dercle, L., Henry, T., Carré, A., Paragios, N., Deutsch, E., & Robert, C. (2020) · Methods · doi:10.1016/j.ymeth.2020.07.003 · Cited by 41
Kaźmierska, J., Hope, A. J., Spezi, E., Beddar, S. A., Nailon, W. H., Osong, B., Ankolekar, A., Choudhury, A., Dekker, A. L. A. J., Redalen, K. R., et al. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.054 · Cited by 51
Manafi‐Farid, R., Ziarati, N. K., Vali, R., Mottaghy, F. M., & Beheshti, M. (2020) · Methods · doi:10.1016/j.ymeth.2020.05.023 · Cited by 47
Carles, M., Fechter, T., Grosu, A., Sörensen, A., Thomann, B., Stoian, R., Wiedenmann, N. E., Rühle, A., Zamboglou, C., Ruf, J., et al. (2021) · Cancers · doi:10.3390/cancers13143449 · Cited by 47
Wu, Y.-J., Liu, Y.-C., Liao, C.-Y., Tang, E., & Wu, F. (2021) · Scientific Reports · doi:10.1038/s41598-020-79690-4 · Cited by 46
Radiomics for Identification and Prediction in Metastatic Prostate Cancer: A Review of Studies
Kendrick, J., Francis, R. J., Hassan, G. M., Rowshanfarzad, P., Jeraj, R., Kasisi, C., Rusanov, B., & Ebert, M. A. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.771787 · Cited by 46
Zhong, J., Xia, Y., Chen, Y., Li, J., Lu, W., Shi, X., Feng, J., Yan, F., Yao, W., & Zhang, H. (2022) · European Radiology · doi:10.1007/s00330-022-09119-1 · Cited by 46
FET-PET radiomics in recurrent glioblastoma: prognostic value for outcome after re-irradiation?
Carles, M., Popp, I., Starke, M. M., Mix, M. D., Urbach, H., Schimek‐Jasch, T., Eckert, F., Niyazi, M., Baltas, D., & Grosu, A. (2021) · Radiation Oncology · doi:10.1186/s13014-020-01744-8 · Cited by 45
Leithner, D., Nevin, R., Gibbs, P., Weber, M., Otazo, R., Vargas, H. A., & Mayerhoefer, M. E. (2023) · Investigative Radiology · doi:10.1097/rli.0000000000000970 · Cited by 44
Chen, Y., Wang, T., Chu, S., Lin, C., Wang, L.-Y., Lue, K., Liu, S., & Chan, S.-C. (2020) · PLoS ONE · doi:10.1371/journal.pone.0244502 · Cited by 43
Lue, K.-H., Wu, Y.-F., Lin, H.-H., Hsieh, T.-C., Liu, S.-H., Chan, S.-C., & Chen, Y.-H. (2020) · Diagnostics · doi:10.3390/diagnostics11010036 · Cited by 33
Song, Y., Zhou, G., Zhou, Y., Xu, Y., Zhang, J., Zhang, K., He, P., Chen, M., Liu, Y., Sun, J., et al. (2023) · Hepatology International · doi:10.1007/s12072-023-10487-z · Cited by 43
Wang, H., Zhao, S., Li, L., & Tian, R. (2020) · European Radiology · doi:10.1007/s00330-020-06943-1 · Cited by 42
FDG PET versus CT radiomics to predict outcome in malignant pleural mesothelioma patients
Pavic, M., Bogowicz, M., Kraft, J., Vuong, D., Mayinger, M. C., Kroeze, S. G. C., Friess, M., Frauenfelder, T., Andratschke, N. H., Huellner, M. W., et al. (2020) · EJNMMI Research · doi:10.1186/s13550-020-00669-3 · Cited by 42
Potentials and caveats of AI in hybrid imaging
Sundar, L. K. S., Muzik, O., Buvat, I., Bidaut, L. M., & Beyer, T. (2020) · Methods · doi:10.1016/j.ymeth.2020.10.004 · Cited by 43
Chen, Y., Zhong, J., Wang, L., Shi, X., Lu, W., Li, J., Feng, J., Xia, Y., Chang, J. R., Fan, J., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08628-3 · Cited by 41
The Machine Learning Model for Distinguishing Pathological Subtypes of Non-Small Cell Lung Cancer
Zhao, H., Su, Y., Wang, M., Lyu, Z., Xu, P., Jiao, Y., Zhang, L., Han, W., Tian, L. H., & Fu, P. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.875761 · Cited by 41
Evaluating the impact of the Radiomics Quality Score: a systematic review and meta-analysis
Barry, N., Kendrick, J., Molin, K., Li, S., Rowshanfarzad, P., Hassan, G. M., Dowling, J., Parizel, P. M., Hofman, M. S., & Ebert, M. A. (2025) · European Radiology · doi:10.1007/s00330-024-11341-y · Cited by 41
Quantitative Radiomics Features in Diffuse Large B-Cell Lymphoma: Does Segmentation Method Matter?
Eertink, J. J., Pfaehler, E. A. G., Wiegers, S. E., van, T. O., de Brug, Lugtenburg, P. J., Hoekstra, O. S., Zijlstra, J. M., de Vet, H. C. W., & Boellaard, R. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262117 · Cited by 40
Lisson, C. S., Lisson, C. G., Mezger, M. F., Wolf, D., Schmidt, S. A., Thaiss, W. M., Tausch, E., Beer, A. J., Stilgenbauer, S., Beer, M., et al. (2022) · Cancers · doi:10.3390/cancers14082008 · Cited by 39
Anan, N., Zainon, R., & Tamal, M. (2022) · Insights into Imaging · doi:10.1186/s13244-021-01153-9 · Cited by 39
Thyroid functional and molecular imaging
Giovanella, L., Avram, A. M., Ovčariček, P. P., & Clerc, J. (2022) · La Presse Médicale · doi:10.1016/j.lpm.2022.104116 · Cited by 37
Ren, C., Zhang, J., Qi, M., Zhang, J., Zhang, Y., Song, S., Sun, Y., & Cheng, J. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05226-1 · Cited by 37
Koçak, B., Kaya, O. K., Erdim, Ç., Kuş, E. A., & Kılıçkesmez, Ö. (2020) · American Journal of Roentgenology · doi:10.2214/ajr.20.22847 · Cited by 36
Liberini, V., Santi, B. D., Rampado, O., Gallio, E., Dionisi, B., Ceci, F., Polverari, G., Thuillier, P., Molinari, F., & Deandreis, D. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00367-6 · Cited by 36
Carles, M., Fechter, T., Radicioni, G., Schimek‐Jasch, T., Adebahr, S., Zamboglou, C., Nicolay, N. H., Martí‐Bonmatí, L., Nestle, U., Grosu, A., et al. (2021) · Cancers · doi:10.3390/cancers13040814 · Cited by 35
Artificial Intelligence for Response Evaluation With PET/CT
Wei, L., & Naqa, I. E. (2020) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2020.10.003 · Cited by 35
Dimitrakopoulou‐Strauss, A., Pan, L., & Sachpekidis, C. (2021) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2021.10.002 · Cited by 34
Koçak, B., Bulut, E., Bayrak, O. N., Okumus, A. A., Altun, O., Arvas, Z. B., & Kavukoglu, I. (2023) · European Journal of Radiology · doi:10.1016/j.ejrad.2023.110830 · Cited by 34
Albano, D., Gatta, R., Marini, M., Rodella, C. A., Camoni, L., Dondi, F., Giubbini, R., & Bertagna, F. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10215064 · Cited by 33
Guglielmo, P., Marturano, F., Bettinelli, A., Gregianin, M., Paiusco, M., & Evangelista, L. (2021) · Cancers · doi:10.3390/cancers13236026 · Cited by 33
Radiomic Features of 18F-FDG PET in Hodgkin Lymphoma Are Predictive of Outcomes
Zhou, Y.-Y., Zhu, Y.-C., Chen, Z., Li, J.-H., Sang, S.-B., & Deng, S.-M. (2021) · Contrast Media & Molecular Imaging · doi:10.1155/2021/6347404 · Cited by 29
Radiomics-guided radiation therapy: opportunities and challenges
Abdollahi, H., Chin, E., Clark, H., Hyde, D. E., Thomas, S., Wu, J., Uribe, C., & Rahmim, A. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac6fab · Cited by 33
López, O. V. G., Herraiz, J. L., Udías, J. M., Haug, A. R., Papp, L., Cioni, D., & Neri, E. (2022) · Cancers · doi:10.3390/cancers14122922 · Cited by 33
Evaluation of FET PET Radiomics Feature Repeatability in Glioma Patients
Gutsche, R., Scheins, J. J., Köcher, M., Bousabarah, K., Fink, G. R., Shah, N. J., Langen, K., Galldiks, N., & Lohmann, P. (2021) · Cancers · doi:10.3390/cancers13040647 · Cited by 33
Molecular Imaging for Thyrotoxicosis and Thyroid Nodules
Giovanella, L., Avram, A. M., & Clerc, J. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.246017 · Cited by 32
The stability of oncologic MRI radiomic features and the potential role of deep learning: a review
Scalco, E., Rizzo, G., & Mastropietro, A. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac60b9 · Cited by 32
What a Radiologist Needs to Know About Radiomics, Standardization, and Reproducibility
Huisman, M., & D’Antonoli, T. A. (2024) · Radiology · doi:10.1148/radiol.232459 · Cited by 32
Zhan, Y., Hao, Y., Wang, X., & Guo, D. (2025) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2025.104682 · Cited by 32
Functional imaging using radiomic features in assessment of lymphoma
Mayerhoefer, M. E., Umutlu, L., & Schöder, H. M. (2020) · Methods · doi:10.1016/j.ymeth.2020.06.020 · Cited by 30
Wang, K., Dohopolski, M. J., Zhang, Q., Sher, D. J., & Wang, J. (2022) · Medical Physics · doi:10.1002/mp.16132 · Cited by 31
Value of PET imaging for radiation therapy
Lapa, C., Nestle, U., Albert, N. L., Baues, C., Beer, A. J., Buck, A. K., Budach, V., Bütof, R., Combs, S. E., Derlin, T., et al. (2021) · Strahlentherapie und Onkologie · doi:10.1007/s00066-021-01812-2 · Cited by 30
Radiomics Analysis of 3D Dose Distributions to Predict Toxicity of Radiotherapy for Cervical Cancer
Lucia, F., Bourbonne, V., Visvikis, D., Miranda, O., Gujral, D. M., Gouders, D., Dissaux, G., Pradier, O., Tixier, F., Jaouen, V., et al. (2021) · Journal of Personalized Medicine · doi:10.3390/jpm11050398 · Cited by 29
Repeatability of 18F-FDG PET Radiomic Features in Cervical Cancer
Crandall, J. P., Fraum, T. J., Lee, M., Jiang, L., Grigsby, P. W., & Wahl, R. L. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.247999 · Cited by 29
Gao, J., Huang, X., Meng, H., Zhang, M., Zhang, X., Lin, X., & Li, B. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.00198 · Cited by 28
Ferrari, R., Trinci, M., Casinelli, A., Treballi, F., Leone, E., Caruso, D., Polici, M., Faggioni, L., Neri, E., & Galluzzo, M. (2024) · La radiologia medica · doi:10.1007/s11547-024-01904-w · Cited by 27
Zhou, Y.-Y., Li, J.-H., Zhang, X., Jia, T.-T., Zhang, B., Dai, N., Sang, S.-B., & Deng, S.-M. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.834288 · Cited by 23
Tensor Radiomics: Paradigm for Systematic Incorporation of Multi-Flavoured Radiomics Features
Rahmim, A., Toosi, A., Salmanpour, M. R., Dubljevic, N., Janzen, I., Shiri, I., Ramezani, M. A., Yuan, R., Ho, C., Zaidi, H., et al. (2022) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nss/mic44845.2022.10399050 · Cited by 27
Prenosil, G., Weitzel, T., Fürstner, M., Hentschel, M., Krause, T., Cumming, P. D., Rominger, A., & Klaeser, B. (2020) · PLoS ONE · doi:10.1371/journal.pone.0229560 · Cited by 26
Wei, L., Cui, C., Jiarui, X., Kaza, R. K., Naqa, I. E., & Dewaraja, Y. K. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00340-9 · Cited by 26
Ahrari, S., Zaragori, T., Rozenblum, L., Oster, J., Imbert, L., Kas, A., & Verger, A. (2021) · Biomedicines · doi:10.3390/biomedicines9121924 · Cited by 28
Koçak, B., Chepelev, L. L., Chu, L. C. H., Cuocolo, R., Kelly, B. S., Seeböck, P., Thian, Y. L., van Hamersvelt, R. W., Wang, A., Williams, S. M., et al. (2023) · European Radiology · doi:10.1007/s00330-023-09768-w · Cited by 26
Marfisi, D., Tessa, C., Marzi, C., Meglio, J. D., Linsalata, S., Borgheresi, R., Lilli, A., Lazzarini, R., Salvatori, L., Vignali, C., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-13937-0 · Cited by 25
Metadata
- Authors
- Zwanenburg, A.
- Affiliations
- German Cancer Research Center (DE)
- Corresponding author
- Zwanenburg, Alex
- ORCID
- Zwanenburg, Alex
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2019-06-25
- Volume
- 46
- Issue
- 13
- Pages
- 2638-2655
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2954296981
- Semantic Scholar
- 4615abcf66a67c1823ef58feab4525cb360292fe
- Cited by
- 306
- References
- 174
- Citations by year
- 2026: 16 · 2025: 39 · 2024: 44 · 2023: 51 · 2022: 50 · 2021: 55 · 2020: 48 · 2019: 2
- FWCI
- 25.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- European Journal of Nuclear Medicine and Molecular Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image Retrieval and Classification Techniques
- Keywords
- radiomics, positron emission tomography, reproducibility, multicenter study, voxel size, image segmentation, image reconstruction parameters, SUVmax, SUVmean, data analysis pitfalls, information leakage, model validation, reporting bias, standardization
- MeSH terms
- Data Analysis, Humans, Image Processing, Computer-Assisted, Nuclear Medicine, Reference Standards
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.