Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 280

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Repair of Giant Midline Abdominal Wall Hernias: “Components Separation Technique” versus Prosthetic Repair: Interim Analysis of a Randomized Controlled Trial

Open access
Reilingh, T. S. de Vries, van Goor, H., Charbon, J. A., Rosman, C., Hesselink, E. J., van der Wilt, G. J., Bleichrodt, R. P. · 2007 · World Journal of Surgery

Abstract

Background: Reconstruction of giant midline abdominal wall hernias is difficult, and no data are available to decide which technique should be used. It was the aim of this study to compare the “components separation technique” (CST) versus prosthetic repair with e‐PTFE patch (PR). Method: Patients with giant midline abdominal wall hernias were randomized for CST or PR. Patients underwent operation following standard procedures. Postoperative morbidity was scored on a standard form, and patients were followed for 36 months after operation for recurrent hernia. Results: Between November 1999 and June 2001, 39 patients were randomized for the study, 19 for CST and 18 for PR. Two patients were excluded perioperatively because of gross contamination of the operative field. No differences were found between the groups at baseline with respect to demographic details, co‐morbidity, and size of the defect. There was no in‐hospital mortality. Wound complications were found in 10 of 19 patients after CST and 13 of 18 patients after PR. Seroma was found more frequently after PR. In 7 of 18 patients after PR, the prosthesis had to be removed as a consequence of early or late infection. Reherniation occurred in 10 patients after CST and in 4 patients after PR. Conclusions: Repair of abdominal wall hernias with the component separation technique compares favorably with prosthetic repair. Although the reherniation rate after CST is relatively high, the consequences of wound healing disturbances in the presence of e‐PTFE patch are far‐reaching, often resulting in loss of the prosthesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00268-006-0502-x

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 280

Metadata

Authors
Reilingh, T. S. D. V., van Goor, H., Charbon, J. A., Rosman, C., Hesselink, E. J., van der Wilt, G. J., & Bleichrodt, R. P.
Venue
World Journal of Surgery
Publisher
Wiley
Published
2007-03-05
Volume
31
Issue
4
Pages
756-763
ISSN
  • 0364-2313 (ISSN-L)
  • 1432-2323
OpenAlex
W2113816452
Cited by
280
References
12
FWCI
9.78
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repair of Giant Midline Abdominal Wall Hernias: “Components Separation Technique” versus Prosthetic Repair: Interim Analysis of a Randomized Controlled Trial. https://app.cochat.ai/papers/10.1007/s00268-006-0502-x
The paper
Reilingh, T. S. D. V., van Goor, H., Charbon, J. A., Rosman, C., Hesselink, E. J., van der Wilt, G. J., & Bleichrodt, R. P. (2007). Repair of Giant Midline Abdominal Wall Hernias: “Components Separation Technique” versus Prosthetic Repair: Interim Analysis of a Randomized Controlled Trial. World Journal of Surgery. https://doi.org/10.1007/s00268-006-0502-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.