Biological evaluation of poly-l-lactic acid composite containing bioactive glass
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104 · cited 1×
“This biochemical test is based in the reduction of MTT (which is water-soluble salt and has a yellow tonality) by the cell mitochondrial enzyme succinate dehydrogenase, yielding a purple-color salt insoluble in water [ 25 ].”
MethodSynthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741 · cited 1×
“Poly-L-lactic acid (PLLA) and its copolymer have been very attractive to biomedical materials due to their controllable biodegradability and the safety of their degraded products [ 1 , 2]. However, these polymers may elicit inflammatory response in the host tissue because of the release of acidic degradation products…”
BackgroundBiodegradable polymeric scaffolds for musculoskeletal tissue engineering
Agrawal, C. M., & Ray, R. B. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<141::aid-jbm1000>3.0.co;2-j · Cited by 1,052 · cited 1×
“Poly-L-lactic acid (PLLA) and its copolymer have been very attractive to biomedical materials due to their controllable biodegradability and the safety of their degraded products [1, 2]. However, these polymers may elicit inflammatory response in the host tissue because of the release of acidic degradation products an…”
BackgroundGriffith, L. G. (2000) · Acta Materialia · doi:10.1016/s1359-6454(99)00299-2 · Cited by 730
Interaction of cultured human endothelial cells with polymeric surfaces of different wettabilities
van Wachem, P. B., Beugeling, T., Feijen, J., Bantjes, A., Detmers, J. P., & van Aken, W. G. (1985) · Biomaterials · doi:10.1016/0142-9612(85)90101-2 · Cited by 591 · cited 1×
“It indicates that no cytotoxic effect was observed for the PLLA/BG composite, and in addition, a significant increase in cellular activity was found, suggesting that the bioactive in the composite was able to stimulate cellular activity by creating a favorable microenvironment for cell proliferation and growth [ 27 ].”
BackgroundRoether, J. A., Boccaccini, A. R., Hench, L. L., Maquet, V, Gautier, S., & Jérôme, R. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00131-x · Cited by 358 · cited 1×
“Bioactive glasses can bond to living bone directly, which is due to the formation of biologically active carbonate containing hydroxyapatite on their surfaces when implanted in bony defects [ 7 ].”
BackgroundBiocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility
Fournier, E., Passirani, C., Montero-Menei, C. N., & Benoit, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00161-3 · Cited by 353 · cited 1×
“It is equally important to consider the changes in the local environment created by a composite which includes a highly reactive phase before in vivo testing of the material, as these changes may have considerable effects on the behavior of the cells [ 18 , 19].”
BackgroundKarp, J. M., Shoichet, M. S., & Davies, J. E. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10420 · Cited by 176
Degradation of poly(d,l)lactide implants with or without addition of calciumphosphates in vivo
Heidemann, W., Jeschkeit, S., Ruffieux, K., Fischer, J. H., Wagner, M., Krüger, G., Wintermantel, E., & Gerlach, K. L. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00424-5 · Cited by 173
Bosetti, M., Zanardi, L., Hench, L. L., & Cannas, M. F. (2002) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10415 · Cited by 128
Research works printed but not linked: 2
- Groth T, Altankov G (1998) Cell-surface interactions and the tissue compatibility of biomedical materials. IOS Press, Washington, p 12
- He Y, Yang SH, Li T (2008) Preparation and in vivo biocompatibility of a novel thermosensitive hydrogel. J Clin Rehab Tissue Eng Res 12:1157–1160
Cited by
Farah, S., Anderson, D. G., & Langer, R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.012 · Cited by 3,443
Naser, A. Z., Deiab, I., & Darras, B. M. (2021) · RSC Advances · doi:10.1039/d1ra02390j · Cited by 836
Bergström, J. S., & Hayman, D. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1455-8 · Cited by 266
Cardiovascular stents: overview, evolution, and next generation
Borhani, S., Hassanajili, S., Ahmadi Tafti, S. H., & Rabbani, S. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0097-y · Cited by 226
Wang, A., Venezuela, J., & Dargusch, M. S. (2022) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2022.107301 · Cited by 31
PLLA/ZnO nanocomposites: Dynamic surfaces to harness cell differentiation
Trujillo, S., Lizundia, E., Vilas‐Vilela, J. L., & Salmerón‐Sánchez, M. (2016) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2016.04.007 · Cited by 26
Ashok Raja, C., Balakumar, S., Purushothaman, B., Rajashree, P., Anandkumar, B., George, R. P., & Mudali, U. K. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.04.040 · Cited by 24
Císař, J., Pummerová, M., Drőhsler, P., Masař, M., & Sedlařík, V. (2025) · Polymers · doi:10.3390/polym17101326 · Cited by 22
“This finding agrees with those of other studies [45], in which fillers with a hydrophilic character absorbed more water than the PLA matrix, thereby complicating hydrolytic degradation and biodegradation of the material.”
Biological Assessment of Composite Materials Based on Poly-L-lactide and Bovine Bone
Zhou, Z., Liu, L., Liu, Q., Yi, Q., Zhao, Y., Zeng, W., & Liu, X. (2013) · International Journal of Polymeric Materials · doi:10.1080/00914037.2012.664213 · Cited by 16
Self-citationDegradation and Stability of Poly(lactic Acid)
Sin, L. T., Rahmat, A. R., & Rahman, W. A. W. A. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-4459-0.00007-x · Cited by 15
Polymer-based composites for musculoskeletal regenerative medicine
Poh, P. S. P., Woodruff, M. A., & García‐Gareta, E. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102906-0.00003-9 · Cited by 10
Evaluation of Biological Properties of Collagen/Hyaluronic Acid Composite Scaffolds
He, Z., & Xiong, L. (2013) · Polymers and Polymer Composites · doi:10.1177/096739111302100707 · Cited by 9
Degradation and Stability of Poly(Lactic Acid)
Sin, L. T., & Tueen, B. S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814472-5.00007-8 · Cited by 8
Modification of biodegradable materials by natural biocidal agents
Stepczyńska, M. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-818431-8.00008-8 · Cited by 4
Wang, X., Sang, L., Wei, Z., Zhai, L., Wang, H., Song, K., & Qi, M. (2014) · Polymer Engineering and Science · doi:10.1002/pen.23851 · Cited by 2
Zhou, Z., Yi, Q., Gao, Y., Liu, L., Liu, Q., Zhao, Y., Zeng, W., Zhou, J., & Yang, Z. (2011) · Polymers and Polymer Composites · doi:10.1177/096739111101900910 · Cited by 2
Self-citationChen, Y. Y., Liu, H., Murphy, E. J., Fehrenbach, G. W., de Lima, T. A. D. M., George, D., Burke, N., & Flanagan, A. (2025) · Results in Engineering · doi:10.1016/j.rineng.2025.107458 · Cited by 1
Metadata
- Authors
- Zhou, Z., Zhou, J., Yi, Q., Liu, L., Zhao, Y., Nie, H., Liu, X., Zou, J., & Chen, L.
- Affiliations
- Hunan University of Science and Technology (CN)
- Central South University (CN)
- Corresponding author
- Zhou, Zhihua
- ORCID
- Venue
- Polymer Bulletin
- Published
- 2010-03-14
- Volume
- 65
- Issue
- 4
- Pages
- 411-423
- ISSN
- 0170-0839 (ISSN-L)
- 1436-2449
- OpenAlex
- W2073901519
- Cited by
- 17
- References
- 29
- Citations by year
- 2025: 2 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 2 · 2016: 2 · 2015: 1 · 2014: 1 · 2013: 2 · 2012: 1
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Polymer Bulletin (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- poly(L-lactic acid), bioactive glass, polymer composites, biodegradable implants, biocompatibility, hemolysis, cytotoxicity, fibroblast adhesion, fracture healing, ankle fractures, acute systemic toxicity, genotoxicity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.